Southern Railway - Tamil Nadu
39162065 supply of drug eluting balloon catheter , self expandable transcatheter aortic valve implant set , micropuncture set , self expandable peripheral stent , aortic stent graft., ( sr ph code 152003 ) drug eluting balloon catheter ( deb ) for coronary angioplasty. unit: no , ( sr ph code 152101 ) self expandable transcatheter aortic valve implant set consists of the following in sterile individual pack, ( i ) .transcatheter heart valve 01 unit. it should be made of bovine / porcine pericardium tri leaflet valve , made of medical grade alloy. the size of the valve should range from 20 mm to 35 mm or more. ( ii ) .valve delivery system 01 unit ( iii ) .balloon dilatation catheter 02 unit balloon size ranges from 16 mm to 35 mm with 30 mm length for pre and post dilation. ( iv ) .introducer sheath 01 unit compatible with all valve sizes. should have haemostatic valve should be compatible for femoral artery size ranging from 5 mm to 7 mm. ( v ) inflation device 02 units ( 30ml / 40ml / 60ml ) ( vi ) syringes 50cc 02 units ( vii ) extra support double curve 0.035inch wire 240cm for valve delivery ( viii ) suture mediated vascular closure device 2 units. ( ix ) temporary pacing lead 01 unit for burst pacing. the firm should be able to supply any size of valve, delivery system and balloon suitable for the patient. unit: no. , ( sr ph code 152053 ) micropuncture set consisting of 5fr inroducer 21g introducer needle and nitinol 0.018 inch guide wire ( unit number ) , ( sr ph code 152054 ) micropuncture set consisting of 4fr inroducer 21g introducer needle and nitinol 0.018 inch guide wire ( unit number ) , ( sr ph code 153016 ) self expandable peripheral stent of various sizes for illac and femoral stenting. ( unit number ) , ( sr ph code 153060 ) aortic stent graft : should enable endovascular treatment of arch of aorta and descending thoracic aorta aneurysms and dissections. the stent graft should come in various lengths and diameters. it should consist of ( 1 ) a self expanding, tubular endoprosthesis composed of a polyester graft fabric and a spring scaffold made from nitinol wire. ( 2 ) radiopaque markers are to be sewn to the fabric to radiographically visualize the edge of the graft material to provide a guide to the minimum overlap distance required. ( 3 ) a pre loaded delivery system. ( 4 ) aortic occlusion balloon to assess the aneurysm / dissection with angiography ( 5 ) marker pigtail to assess in proper sizing and deployment. ( unit number ) , ( sr ph code 153061 ) aortic stent graft : should enable endovascular treatment of aortic aneurysms and dissections. the stent graft should come in various lengths and diameters, which should be two component an aortoiliac bifurcated and a contralateral limb. it should consist of ( 1 ) a self expanding, stent graft composed of fabric and scaffold made from nitinol wire. ( 2 ) radiopaque markers are to be sewn to the fabric. ( 3 ) should able to add additional configurations include iliac and aortic extensions . ( 4 ) aortic occlusion balloon to assess the aneurysm / dissection with angiography ( 5 ) marker pigtail to assess in proper sizing and deployment. ( unit number ) ...