Military Engineer Services - Tamil Nadu

35118496 construction of temporary ops equipment room with required facilities at rameshwaram under ge tirunelveli 2 excavation in trenches n exc 1.5m in depth for foundation etc or for shafts, wells, cess pits, manholes pier holes etc n exc10 sqm on plan and getting out in soft soil all as specified and as directed. 3 excavation in trenches n exc 1.5m in depth for foundation etc or for shafts, wells, cess pits, manholes pier holes etc n exc10 sqm on plan and getting out in soft disintegrated rock all as specified and as directed. 4 material and labour cement concrete in foundation filling and mass concrete type d2 1:4:8 ( 40mm graded aggregate ) complete all as specified and as directed. 5 material and labour mild steel tmt bar 10mm dia and over cut to length, bent to shape required, including cranking, bending with mild steel wire not less than 0.9mm dia or securing with clips complete all as specified and as directed. 6 ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. 7 formwork to the sides of concrete foundation, bases of columns / sides and soffits of foundation and plinth beams complete all as specified and as directed. 8 formwork to sides of column complete all as specified and as directed. 9 formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed 10 material and labour rcc m30 grade foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as directed. 11 material and labour rcc m30 columns, pillars, piers, posts and struts complete all as specified and as directed. 12 material and labour rcc m30 beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. 13 formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. 14 material and labour rcc m30 grade for chajjas ( 20mm graded aggregate ) complete all as specified and as directed. 15 material and labour pcc 1:2:4 type b0 40mm thick using 12.5mm aggregate as in sub base complete all specified and as directed. 16 material and labour hardcore of gauge n exc. 63mm, deposited, spread and leveled in layers n exc. 15cm thick, watered and rammed to a true surface with broken stone boulders complete all as specified and as directed. 17 material and labour moorum filling in floors or pavings, laid in layers n exe 15cm thk spread, leveled and rammed including watering all as specified and as directed. 18 material and labour 100mm thk pcc 1:2:4 type b1 ( using 20mm graded stone aggregate ) as in floors all as specified and as directed. 19 material and labour 100mm thk pcc 1:4:8 type d2 ( using 40mm graded stone aggregate ) as in floors all as specified and as directed. 20 material and labour virified ceramic tiles dark shade 10 mm thick ( square / rectangular ) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thk screed bed in cm 1:4 in floors etc complete all as specified and as directed. 21 all as item no 20 above but on vertical surface such as dado / skirting etc over and including 10mm thick rendering in cm 1:4 etc complete all as specified and as directed. 22 material and labour for brickwork with sub base b bricks ( old size ) , straight or curved on plan exe 6m radius mean radius built in cm 1:6 all as specified and as directed. 23 material and labour brickwork with subclass ‘b’ bricks, straight or curved on plan to any radius in half brick thick walls built in cm 1:3 complete all as specified and as directed. 24 material and labour for rendering 15mm thick on fair faces of brick work or concrete surface of wall even and smooth without using extra cement in cm 1:6 complete all as specified and as directed. 25 material and labour preparation of newly plastered surfaces of wall by vacuum based sanding machine and applying two coats of oil bound distemper by auto roller over a coat of alkaline resistant primer over a coat of 3mm wall care putty ( multipurpose mixer shall be used for uniform and proper mixing of putty ) , complete all as specified and as directed. 26 material and labour for rendering 15mm in two layers with 5mm thk in cm 1:3 with wpc over 10mm thk in cm 1:6 on fair faces of brick work or concrete surfaces and to be finished even and smooth with water proofing compound ( without using extra lime or cement ) complete all as specified and as directed. 27 supply only integral water proofing compound complete all as specified and as directed. 28 material and labour preparation of new plastered surface on wall vacuum based sanding machine and applying two coats of 100% premium acrylic emulsion paint in camouflage pattern having voc less than 50g / lit and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade ( company depot tinted ) with silicon adhesive at 1.43lit / 10 sqm over and including of priming coat of exterior primer applied at 0.9lit / 10sqm over new surfaces by auto roller including priming coat with primer all as specified and as directed . 29 supply and fixing factory made upvc white colour casement door with top hung ventilator with 3d and ss friction ( 400 x 19 x 1.9 mm ) made of ( big series ) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 + 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of door upto 2.50 sqm ) comprising of upvc multi chambered frame, sash and mullion ( where ever required ) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , upvc extruded glazing beads of appropriate dimension, epdm gasket, zinc alloy ( white powder coated ) 3d hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion ( if required ) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality complete all as specified and directed by engineer in charge. ( glazing shall be measured and paid separately ) 30 providing and fixing factory made upvc white colour sliding window three track made of extruded profiles with wall thickness of 2.3mm ( + 0.2mm ) . window profile with hollow section with multi chamber. frame ( 88mm x 52mm ) , sliding sash ( 42mm x 67mm ) . sliding mesh sash ( 42mm x 57mm ) sliding interlock ( one vertical length in each shutters ) ( 45.5mm x 28mm ) , glazing bead ( 24.5mm x 16mm ) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. epdm gasket, 1.2+ 0.2mm thick galvanised steel frame ( 30mm x 18mm ) 2 nos, sliding sash ( 30mm x 18mm ) , sliding mesh sash ( 26mm x 10mm ) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, hardware [ touch lock of zinc alloyed ( white powder coated ) , steel roller system. stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. ( note: the unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. net opening will be measured for payment purpose. ) 31 supply and fixing pre painted galvalume single skin corrugated profiled roofing sheet of 0.50mm thickness ( total coated metal thickness ) having tensile strength of 550 mpa, coated with hot dip metallic zinc aluminium alloy coating zincalume az 150 or equivalent ( as per as 1397 ) @ 150 gms / sqm, total on both sides of zn ( 45% ) & al ( 55% ) , with super polyester colour bond xrw quality paint coat or equivalent as per as / nzs 2728 ( category 3 4 ) of approved colour, total coating thickness of 35 microns of a super polyester xrw quality paint system or equivalent comprising of 20 microns ( nom ) exterior coat on top surface and 5 microns ( nom ) reverse coat on back surface over 5 microns ( nom ) primer coat, on both surface, of approved colour shade fixed with gi self tapping fastening bolt / screw as in roof covering / cladding etc as per manufacturers instructions complete all as specified and as directed. 32 supply and fixing prepainted galvalume aluminium zinc coating gi based plain / corrugated steel sheet 0.5mm thk of an colour having tensile strength of 550mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified. 33 supply and fixing rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to fe 410w ( gde 250 ) complete all as specified and as directed. 34 supply and fixing roof trusses ( framed ) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing ( beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc complete all as specified and as directed. 35 supply and fixing plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed. 36 supply and fixing bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks ( stay ) , heavy, for large gates; hook and pin hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to fe 290 gde e 165 37 supply and fixing mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n exc 30cm long complete all as specified and as directed. 38 material and labour preparation of new steel surfaces over 10 cm in width of girth and applying two coat on synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 39 supply and fixing of armstrong mineral fibre acoustical suspended ceiling system with fine fissured ( bevelled tegular ) edge tiles with armstrong 15mm exposed grid. the tiles should have humidity resistance ( rh ) of 99%, nrc 0.6, light reflectance > 85%, thermal conductivity k = 0.052 0.057w / m k, colour white, fire performance uk class 0 / class 1 ( bs 476 pt 6&7 ) in module size of 600 x 600 x 16 mm, suitable for green building application, with recycled content of 31%. the tils shall be laid on armstrong suprafine 32 with 15 mm wide t section flanges colour white having rotary stitching on all t sections i.e. the main runner, 1200 mm & 600 mm cross tees with a web height of 32 mm and a load carrying capacity of 7.5kg / m2 & minimum pull out strength of 100 kgs. the t section have galvaning of 90grams per m2 and need to be installed with suspension system complete all as specified and as directed. 40 supply and fixing powder coated anodised aluminum frame / shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. 41 supply and fixing 6mm thick toughened glass fixed with necessary fixing arrangements all as specified and as directed. 42 material and labour 18 / 19mm thk prelaminated particle board, exterior grade prelaminated both sides with decorative choice lamination fixed with screw all as specified and as directed. 43 returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in soils all as specified and directed. 44 removing excavated material exc 250 m but n exc 500 m and depositing where directed all as specified and directed. 45 supply and fixing 40mm continuous ( piano ) hinges, brass bright finish or eletro galvanised all as specified and as directed. 46 supply and fixing locks, drawer, grader 1, 2 lever size 50mm complete all as specified and as directed. 47 supply and fixing 75mm brass handle cast type polished bright all as specified and as directed. 48 material and labour 75mm thk pcc ( 1:3:6 ) type c1 cement concrete for plinth protection ( 20mm graded aggregate finished even smooth without using extra cement ) complete all as specified and as directed. 49 material and labour treating the soil under plinth protection at the rate of 5 litres of emulsion per sq.m of surface area complete all as specified and as directed. 50 material and labour treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. 51 material and labour treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed 52 material and labour treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed. 53 supply and fixing 20mm thick granite ( of any type ) tiles machine cut, in skirting / dado / vertical surfaces laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete and including 10mm thick screed bed or bedding layer of mortar in cm 1:4 complete all as specified and directed. 54 internal electrification 55 material and labour for replacement of point wiring with two single core 1100 v grade frls h conforming to is 694 pvc insulated unsheathed cables of size 1.5 sq mm multi stranded copper conductor drawn through and including rigid pvc conduit and conduit accessories fixed on surface including breaking of walls and making good to disturbed surfaces in wall / roof / ceiling where required complete with 3 mm hylam sheet cover with an earth wire of pvc cable 1.5 sqmm multi stranded copper conductor and connected to all metal boxes and common earth dolly all as specified and directed for the following : 55.01 ( a ) one light point or fan point controlled by one switch complete 55.02 ( a ) one 3 pin socket outlet 5 amps on same board complete 55.03 ( a ) one 3 pin socket outlet 5 amps on independent board complete 56. description same as item no. 55 but for 4.0 sqmm single core pvc sheathed frls h copper conductor cable for 3 pin socket outlet 15 amps on independent board 57. material and labour for ceiling rose, surface bakelite, 65x50mm, two to three terminals, complete all as specified and as directed by the engineer in charge 58. supply and fix switch socket combination 2 in 1, 3 pin, 5 amp complete all as specified and as directed. 59. supply and fix switch socket combination 2 in 1, 3 pin, 5 and15 amp flush type universal complete all as specified and as directed. 60. supply and fix switch piano flush type single pole one way 5 a 240 volts complete all as specified and as directed 61. supply and fix recessed mounting 2 ft x 2 ft led luminaries with initial luminous flux ( system flux ) 10000 lm, initial led luminaries efficacy 150 lm / w, color temperature 6500 k suitable for false ceiling complete with all accessories internally pre wired complete all as specified and as directed. make : philips, model ; full glow cat. part no rc380b led25s 6500 g5 l60w60 psu od or equivalent makes as specified in ps 62. supply and fixing led lights fitting 1x 18 w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.. make: philips , model smartbright , cat part no bn021c led22s psu cw gr or equivalent makes as specified in ps 63. supply and fixing led light fitting 1x6w bulkhead luminaires, initial luminous flux ( system flux ) 700 lm , initial led luminaries efficacy 110 lm / w , ip66 protection and ik09 impact resistance including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.. make : philips, model enduraled bulkhead, wt202w led6s cw psu s2 pc or equivalent makes as specified in ps . 64. material and labour for single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole mcb 240 v, 20 amp complete all as specified and as directed by the engineer in charge 65. material and labour sub main wiring with two single core 1100 v grade conforming to is 694 pvc insulated unsheathed cables 4 sq mm frlsh multi stranded copper conductor drawn through and incl 32 mm dia non metallic pvc rigid conduit and conduit accessories fixed on walls / roof / floors / ceiling etc with an earth wire of one run 4 sqmm frlsh copper wire earth continuity conductor etc complete all as specified and directed by engr in charge. note : three runs of 4 sqmm cable with one run of pvc conduit shall be measured as one run. 66. supply and fix sheet metal enclosure powder coated double door for distribution board, vtpn 4 way db suitable for mccb incomer ip 43 , ik 09 , provided with insulated vertical phase bus bars , neutral bar / s with shroud / s , earth bar / s , sticking saddles , cement spill protector , color coded interconnecting wire set , cable ties , blanking plates and circuit identification labels. complete all as specified and as directed. 67. supply and fix mcb sp 5 a to 32 a , b curve, 10 ka including , complete all as specified and as directed. 68. supply and fix mcb tp 25 63 a , b curve, 10 ka including , complete all as specified and as directed. 69. supply and fix 4 pole mccb 80 a, 25 ka with thermal magnetic release with overload and short circuit protection complete all as specified and as directed. 70. supply and fix wall mounted air circulator 450 mm ( 18 ) , 230 v, 1440 rpm, air delivery 150 cum / min with three speed, vertical adjustable, double ball bearing, 90° oscillation complete all as specified and as directed. make : almonard , model air circulator, 18” tempest wall fan or equivalent as specified in ps 71. supply and fixing led building security light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65 / 66 protection complete all as specified and as directed. make : philips, brp046 led 36 cw mr s1 psu gr or equivalent as specified in ps 72. supply and fix new gi bracket made out of 32 mm dia gi pipe length 1.2 mtr long bent to an angle 135 degree including two coats of aluminium paint over a coat of zinc chromate primer along with clamps, bolts, nuts etc complete all as specified and as directed. 73. material and labour for earthing complete with copper plate electrode 60x60cm x3.15mm thick, buried directly in ground ( earth pit not less than 2.25 metres deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20x3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate no.3 connected to earthing test point, including 20 mm gi pipe ( medium grade ) for watering and 40 mm gi pipe ( medium grade ) for protection of earth strip and etc.. including testing on completion , pcc chambers in pcc1:3:6 type c1, rcc m25 type cover slab 50mm thick with 8mm dia tmt hcr / crs steel bars at 140mm c / c both way and lifting handle gi funnel & wire mesh , funnel, lugs and charcoal, salt etc all as applicable complete all as specified and as directed by the engineer in charge 74. air conditioning 75. supply , install and testing split air conditioner of 1.5 tr capacity with indoor and outdoor units ( copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with bee 5 star rating , with minimum 10 yrs warranty on inverter rotary compressor , complete all as specified and as directed. note : rate quoted is inclusive of the following: ( i ) drain pipe upvc with insulation from indoor unit ( at any floor ) to ground floor level and is to be fixed with necessary clamps complete. ( ii ) drilling hole on the brick wall to facilitate routing of copper pipe, drain pipe and cable from indoor unit to outdoor unit. ( iii ) sealing the hole from outside , after installation, with white cement . ( iv ) pressure testing , cooling performance check and product demonstation . ( v ) 4 core cable of any required length for connecting indoor and outdoor unit. ( vi ) material and labour for fixing remote stand in wall. ( vi ) 3 m copper pipe for interconnecting of indoor and outdoor units. 76. supply and fixing of gi powder coated brackets , for fixing of split acs including grouting with suitable size fasteners complete all as specified and directed. 77. supply and fixing copper pipe 1 / 2 dia with foam insulation including connecting complete all as specified and directed. 78. supply and fixing copper pipe 1 / 4 mm dia with foam insulation including connecting complete all as specified and directed. 79. external electrification 80. material and labour for xlpe insulated, 3.5 core, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 sq.mm complete all as specified and directed. notes: earthwork, excavation and brick protection shall be measured and paid for seperately. 81. excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type of soil, complete all as specified and directed. 82. returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil, complete all as specified and directed. 83. removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the engineer in charge. 84. spreading of riddled earth obtained from trenches for cable cushioning on top and bottom of cable for cable protection complete all as specified and directed. ( note: only punned thickness of riddled earth shall be measured ) 85. supply and lay bricks in trenches , common burnt clay building bricks, subclass `b’ designation 75, old size , with width equal to the length of the brick; laid dry on edge vertically complete all as specified and directed. 86. supply , installation, testing and commissioning of outdoor lt feeder pillar box panel board , cpri approved , made out of crca sheet 3.15 mm thick vermin proof factory made with 40 x 40 x6 mm ms angle / channel duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comprising of high conductivity copper bus bar of capacity 250 amps three phase and neutral including voltmeter, ammeter selector switches, pcc foundation suitable to accommodate the following as specified and as directed.: incoming ( a ) mccb 415 v, 125 a, 4 pole with thermal magnetic protection unit , with overload and short circuit protection breaking capacity, 25 ka 01 nos. ( b ) on load change over switch 4 pole 125 amps 01 no ( c ) digital panel meter multifunctional type for amps, volts, kwh, power factor and other parameters flush mounting with led indication lamp complete and all as per standard practice 1 job out going ( a ) mccb 415 v, 63 a, 4 pole with thermal magnetic protection unit , with overload and short circuit protection breaking capacity, 16 ka 03 nos. note : ( i ) all mccbs / instruments / mcbs / bus bar shall be housed in a separate housing with on off latches in the housing and digital panel meter multifunctional type for amps, volts, kwh, power factor and other parameters flush mounting with led indication lamp for each outgoing complete and all as per standard practice. 87. material and labour for 40mm bore `light grade` galvanised tubes with all fitting, laid in trenches complete all as specified and as directed by the engineer in charge 88. supplying and laying synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per is 15652 2006, ( superseding is 5424 ) suitable for electrical shock safety of sizes 2m x 1m. all as specified and directed by engineer in charge. 89. demolition of cement concrete ( unreinforced ) in ground floors and pavings n exe 15 cm thickness ( below or above ground level ) complete all as specified and as directed by the engineer in charge. 90. material and labour for cable route indicator 150mm dia 3mm thick made out of cast aluminum duly marked with size and type of cable fixed on 40x40x6mm angle iron support embedded in pcc 1;2:4 type b1 using 20 mm graded ( 300x300x400mm size ) and painted with 2 coats of anticorrosive paint over a coat of red oxide primer all as specified and as directed. 91. material and labour for 100 mm thick cement concrete 1:2:4 type b 1, using 20mm graded aggregate for making good the disturbed concrete surface after laying of pipe line over returned filled and compacted earth surface to match with existing concrete surface level complete all as specified and as directed....

Rural Development And Panchayats Department - Tamil Nadu

35049565 tender for appanuthu dindigul district of 4 works tn 05 tpt 02 providing paver block in from aramuthu house to nachimuthu house h / o appanuthu ( length 42m ) estimate amount: rs. 2.443lakhs 2 earthwork excavation for foundation in all clauses of soils and subsoils to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring, struting and bailing out water wherever neccessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick well rammed and consolidated and depositing the surplus earth in all places shown by the departmental officers with initial leads and lifts, etc., including levelling the sites complete complying with std. specifications and as directed.in hard stiff clay, stiff black cotton soil, hard red earth, shale murrams, gravel stoney earth and earth muds with 50% fair sized boulders and hard gravelly soils as per ss20b. 3 cement concrete 1:4:8 mix using 40mm iss hbg metal including cost and conveyance of all matials to site and all labour charges etc., complete. 4 supplying and erecting centering for sides & soffits including supports and strutting up to 3.29m height for plane surfaces in all floors with all cross bracing using mild steel sheets of size 90cm x 60cm and 10 gauge stiffened welded with mild steel angles of size 25mm x 25mm x 3mm for boarding laid over country wood poists of size 10cm x 6.5cm dia spaced at about 90cm center to center etc., complete complying with std. specifications and as directed. for rcc floor slab, roof slab, rectangular, square tee or ell beams, lintel, staircase waise slab, landing slab, landing beam, portico beam, etc., 5 cement concrete 1:3:6 mix using 20mm iss hbg metal including cost and conveyance of all matials to site and all labour charges etc., complete. 6 construction of granular sub base by providing with graded materials of size 9.5mm to 4.75mm metal in 66% & 2.36mm in 34% including spreading in uniform layers with motor grader on propared surface, mixing by mix in place method with rotavator at omc and compacting with three wheeler 80 100 kn static roller coa pcity to acheive the desired dinsity etc., completeas technical specification clause 402 grading c. 7 providing and laying of interlocking concrete block ( surface textured ) pavements having thickness 60mm and compacted over a thin bedding sand layer of 30 mm thickness and joints shall be filled by fine sand of specified grading as per table 1500.6 of specification of rural roads 2014 andtechnical specification clause 1504. 8 provision for name board 9 gst amount for providing service to government contract works for the above construction works. { gst amount is the total gst amount for total overall quoted amount above this row in column bb for all works in this package } 10 construction ofanganwadi building at appanuthu h / o appanuthu estimate amount: rs.13.57 lakhs 11 earthwork excavation and depositing on bank with initial lead and lift in hard gravelly soil for foundation etc. complete. 12 cement concrete 1:4:8 mix using 40mm iss hbg metal including cost and conveyance of all matials to site and all labour charges etc., complete 13 filling in foundation and basement with excavated earth in layers of not more than 15cm. thick well rammed, watered and consolidated complying with standard specifications etc., complete. 14 brick work in c.m 1:5 mix using country bricks including cost & conveyance of all materials to site and all labour charges etc., complete. 15 supplying and erecting shuttering including necessary support for plane surface in foundation basement and roof labs strutting upto 3.29m height for plane surfaces for floors for rcc column footings columns plinth beam and connected with foundations 16 supplying, fabricating and placing in position mild steel or ribbed to steel and all reinforced cement concrete works as per the design given including cost of steel and binding wire in all floors etc. complete. 17 rcc 1:1.5:3 mix using 20 mm iss hbg metal including cost & conveyance of all materials to site and all labour charges etc., complete. 18 cement concrete 1:3:6 mix using 20mm metal including cost and conveyance of all materials to site and labour charges etc. complete. 19 cement concrete 1:2:4 mix using 20mm metal including cost and conveyance of all materials to site and labour charges etc. complete. 20 weathering course with best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime ( no m.sand to be listed ) over the rcc roof slab in the proposition being brickjelly to lime 32:12:1 / 2 by volume and laid over into a single layer and cons 21 finishing the top of the roof with one course of machine pressedtiles of size 20 cm x 2 cm of approved quality laid in cement mortar 1:3 ( one cement and three m.sand ) 12 mm thick mixed with water proofing compound conforming to iss by 2% weight of cement us 22 paving the floor with marbonite tiles of any colour and any size laid in cm 1:2 20mm thick and pointing with white cement 0.4kg / sqm mixed with colouring pigment to suit the colour of the tiles including finishing the joint neatly complying with std specification. 23 dadooing walls with glazed tiles of any colour and any size laid in cm 1:2, 10mm thick. and pointing with white cement 0.4 kg per sqm mixed with colouring pigment to siut the colour of the tiles including finishing the joints neatly complete 24 providing the following thickness of granolithic pattern floor finish with plain cement concrete 1 : 2 : 4 mix using 10 12mm isshbg metal and the top rubed smooth etc., complete 25mm thickness 25 plastering with cm 1:3 mix 10mm thick including cost and conveyance of all materials to site and labour charges etc. complete. 26 plastering with cm 1:5 mix 12mm thick including cost and conveyance of all materials to site and labour charges etc. complete. 27 supplying & fixing iwc 28 supplying & fixing ewc 29 supplying and fabrication of steel doord ( 1.00x2.10m ) 30 supplying and fabrication of steel doord ( 1.10x2.10m ) 31 supplying and fabrication of steel door d1 ( 0.75x1.80m ) 32 supplying and fabrication of steel window w ( 1.2x1.3m ) 33 supplying and fabrication of steel ventilator ( 0.60x0.45m ) 34 providing rain water pipe including all labour charges etc., 35 colour washing two coatswith approved quality of oil bound distemper withgood colour pigments with primerincluding all charges etc. 36 painting two coats with best quality of ready mixed plastic emulison of ist class paintwith appd. colour approved by the departmental officersincluding cost & conveyance of all materials to site and all labour charges etc., complete. 37 painting two coats for black board including all charges etc. complete 38 painting two coats over new iron work using synthetic enamel paint without primer including cost and conveyace of all materials to site etc. complete. 39 electrification 40 supply and fixing of 16 ampsdpic switch of 500v grade with fuse and nutralon suitable t.w. board with painting of suitable colour with pwd earthing ( sd no.142 ) 41 supply and run of 2 of 6 sq. mm ( 84 / 0.30 ) polythene insulated and pvc unsheeted s.c. alu cable of 1100 v on 7 / 20 gi bearerwirefor service connection main sd.66 42 supply and run of 2 x1.5sq. mm ( 22 / .3 ) pvc insulated sc unsheeted cu. conductor of 1100grade in 25mm dia gi pipe ( glassb ) suitably bent at both ends with necessary angle iron upright and end supports for mains sd 69 43 supply and fixing of 11w cfl lamp for existing bh point. ( data b ) sd 80 44 supply and fixing of w.t. bulk head fitting complete with guard suitable for lamp with 60 w bulb with pvc unsheated leads from terminal to the fitting sd. 84 45 wiring with 2 x 1.5 sq.mm pvc uncheated sc cu.cable of 1100 v grade in suitable pvc rigid pipe on wall and ceiling with pvc accessories with t.w. switch box in flush with wall, covered with nylon sheet of 3mm thick with painting of suitable colour for open light point & fan point sd 17 46 wiring with 2 x 2.5 sq.mm pvc uncheated sc alu.cable of 650v grade in suitable pvc rigid pipe on wall and ceiling with pvc accessories with 150 x 100 x 113mm t.w. switch box in flush with wall, covered with nylon sheet of 3mm thick 5 amps 3 pin non inte plug point. sd 36 47 supply and fixing of ceiling fan ( crompton make ) including cost and conveyance of all materials and labour cherges etc complete.ceiling fan sd 114 48 supply and fixing of ac exhaust fan 300mm sweep complete without provision of hole in the wall exhaust fan 300mm sd 115 49 supply and fixing of main service board.etc complete. 50 supplying and fixing of rcc jolly including all charges etc. 51 construction of rain water harvesting including all charges etc. 52 sub estimate pipe line 53 63mm pvc pipe 4ksc 54 63mm pvc mta 55 63mm pvc bend 56 1000litre hdpe tank 57 earth work excavation in all clauses of soil as per ss20b.pipe line 58 providing name board charges 59 gst amount for providing service to government contract works for the above construction works. { gst amount is the total gst amount for total overall quoted amount above this row in column bb for all works in this package } 60 construction ofpublic distribution shop building ( type ii ) at appanuthu h / o appanuthu estimate amount: rs.9.13 lakhs 61 earth work excavation for foundation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 62 supplying and filling in foundation with filling m.sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 63 refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification 64 cement concrete 1:4:8 ( one cement, four m.sand and ten hard broken stone jelly ) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 65 brick work in cement mortar1:5 ( one cement and five m.sand ) using best quality of country bricks of size 8 3 / 4 x 4 1 / 4 x 2 1 / 4for foundation and basement including curing, etc., complete complying with standard specifiction. 66 supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90 x 60 cm and 10 bg stiffened with welded mild steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton 67 supplying, fabricating and placing in position mild steel / ribbed tor steel grills for all rcc works as per design given including cost of steel and g.i. binding wire in all floors etc. complete complying with standard specification. 68 reinforced cement concrete 1:1.5:3 ( one cement, one and a half m.sand and three hard broken stone jelly ) using 20 mm gauge hard broken granite stone jelly for all rcc items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, finishing, curing, etc. and providing fixtures like fan clamps in the rcc floor / roof slabs wherever necessaryetc., complete complying with standard specification and as directed by the departmental officers 69 plastering with cement mortar 1:3 ( one cement and three m.sand ) , 10mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 70 plastering with cement mortar 1:5 ( one cement and five m.sand ) , 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 71 plastering with cement mortar 1:4 ( one cement and three m.sand ) , 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 72 dadooing wall with glazed tiles of any colour of any size laid in c.m 1:2 mix 20 mm thick & pointing with colour cement using 0.40kg per sq.m including cost & conveyance of all materials to site and all labour charges etc.complete 73 paving the floor with cement based hydraulically pressed anti skid tiles ( pattern design ) 20mm thick of approved quality and colour laid in cement mortar 1:3 ( one cement and three sand ) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. 74 providing granolithic floor finish of the 40mm thickness with plain cement concrete 1:2:4 ( one cement, two sand and four aggregate ) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. 75 40mm thick 76 20mm thick 77 finishing the top of roof with one course of machine pressed tiles of size 200mm x 200mm x 20mm of approved quality set in cement mortar 1:3 ( one cement and three sand ) 12mm thick mixed with water proofing compound conforming to iss at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers 78 white washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the departmental officers. 79 supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. 80 painting two coats of newly plastered wall surface with ready mixed plastic exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 81 painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. 82 solid pvc door shutters using 19 gauge 19mm ms square tubes for styles and outer frames. 15mm ms square tubes for top, lock and bottom rails. the steel tubes shall be covered with 5mm thick solid pvc sheets. shutter using 5mm thick solid pvc sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. the over all size of styles shall be 50mm x 30mm. the over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. the over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 83 pvc door d2 of size 0.90 x 2.10m ( single leaf ) 84 aluminium door of size 1.00 x 2.10m 85 fabrication and supply of mild steel window of of the following size with double leaves outer frame made of 35x35x5 mm equal m.s.l angle, mullion section made of 25x25x5mm equal t section, shutter frame madeof 25 x 25 x 5mmequal m.s.l angle for horizontal and vertical members and the shutter frame strengthened by stiffeners of 2 no. horizontal for each shutter using 25 x 25 x 5mmequal m.s. t section fully covered with 18 gauge plain m.s full sheet welded with shutter frame neatly and also fixing by welding protective grill with 12mm square m.s rods at an interval of not greater than 10cm centre to centre to the outer frame, 4 nos. of hold fasts made of 35x35x5 mm equal m.s.l angle , 2 nos. of peg stays with holes for keeping the windows open in different positions, 2 nos. of locking handles, fixing the shutter with 4 nos. of 4 inch hinges with outer frame of the window including painting the whole unit with one coat of best quality of red oxide primer for pds building 86 steel window w of size 1.00m x 1.30m ( double leaf ) 87 fabrication and supply of n type mild steel glazed ventilator ( in two parts ) of of the following size outer frame made of 25x25x5mm equal m.s.l angle with intermediate rails using25 x 25 x 5mmequal m.s. t section for panels with 3mm thick pin headed glass with teak wood beading and glass putty and also fixing by welding protective grill with 12mm square m.s rods at an interval of not greater than 10cm centre to centre to the outer frame, 4 nos. of hold fasts connecting the 2 parts at 75mm clear and with 45 degree inclination with 25x25mm 10g weld mesh and wire mesh including painting the whole unit with one coat of best quality of red oxide primer for pds 88 ventilator of size 0.90m x 0.60m 89 towards the cost of supply and erecting ofpull and push type steel rolling shutterwith isi make using 18 gi sheet and paintedwith one coat of best quality of red oxide primer inclusive of hood covers, transportationcharges etc. complete 90 rolling shutter 91 fabrication supply and fixing in position of aluminium natural colour matt finish fully glazed fixed partition of size 4.50x3.00m size of opening with aluminium grill including all charges etc., complete 92 aluminium partition at office 93 supplyand fixing in position best approved quality and make white glazed earthen ware oriya type indian water closet of size 580 mm with p or s trap embedding the closest and trap to shape in position with brick jelly lime concrete 1:2:5 ( one lime two sand and five brick jelly ) using 40 mm broken brick jelly and finishing the top to required slope and including giving connections to the pvc soil stacks using 0.60 mlong pvc pipe 110 mm dia. 6 kg / sqcm by dismantling masonry, rcc roof or floor slaps and making good, the disturbed portion to original condition without and leakage etc. complete as directed by the departmental officers and complying with standard specifications 94 supply and fixing of best quality approved make colour glazed earthwere wash hand basin of size 550x400mm with all accessoreis such as cast iron brackets, 32mm dia c.p.waste coupling, rubber plug and chain, 32mm dia b class g.i waste pipe, 15mm dia gm wheel valve, 15mm dia nylon connection, 15mm dia brass nipples, 15mm c.p.pillar tap andpedastal including all etc., complete 95 supply and fixing of cuddapah slab of 20 / 30mm thick for shelf arrangements including cost and conveyace of all materials to site and all labour charges etc complete 96 electrification ( 2022 23 sor ) 97 wiring with 2 x 1.5 sq.m ( 22 / 0.3 ) pvc insulated unsheathed sc cu. conductor of 1100v grade in suitable pvc rigid pipe on wall and ceiling with pvc accessories with tw switch box in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open pvc light point / fan point ( for electronic regulator ) s.d.no: 17 98 wiring with 2 x 1.5 sq.m ( 22 / 0.3 ) pvc insulated unsheathed sc cu. conductor of 1100v grade in suitable pvc rigid pipe on wall and ceiling with pvc accessoriesand with 150 x 100 x 113 tw switch box for 5a 3pin non inter locking cs plug with painting of suitable colour with continuos earth wire connection of 14 swg tc wire for open pvc plug s.d.no: 36 99 supply and fixing of 1200mm ( 48 ) ac ceiling fan with stepped electronic 300 w regulator with 1 meter down rod on the existing clamp. s.d.no: 114 100 supply and run of 2 of 6 sq.mm. ( 84 / 0.3 ) pvc insulated sc unsheathed copper conductor of 1100v on 7 / 20 gi s.d.no: 66 101 supply and fixing of single box type 440 w flu fitting complete with copper choke and condensor with tw round blocks on wall or ceiling with flu tube with pvc unsheathed copper leads from terminals to the fitting s.d.no: 88 102 supply and fixing of cfl bulb 11w including cost and conveyance of all materials and labour charges etc complete. sd 80 103 supply and fixing of 16 amps dpic switch of 500v with fuse and neutral ( side handle ) on suitable tw board, with earth connection only. s.d.no: 142 104 supply and run of 2 x 1.5 sq.mm. ( 22 / 0.3 ) pvc insulated single core unsheathed copper conductor of 1100v grade in 25mm dia gi pipe ( class b ) suitably bent at both ends with necessary angle iron upright and end supports for mains ( sd no: 69 ) 105 supply and fixing of tneb meter board suitable for 32a single phase service connection with 32a fuse unit ( 500v ) 32a neutral link and earth link ( 1x1 / 8 copper flat ) on tw plank of size 375mmx300mmx19mm with supporting tw reepers of 1 thick an either side with painting with suitable bolt and nuts for fixing the tw plank on wall with earth connection and inter connection with 7 / 20 pvc insulated copper wire from eb meter to fuse unit sd no: 125 106 supply and fixing of 5a or 10a or 20a ac single phase 230v, 50 hz watt hour metre on suitable tw box complete with earth connections ( sd 124 ) 107 eb deposit amount 108 provision for water supply arrangements etc., 109 supply and fixing of 1000 litre hdpe tank 110 63mm dia pvc pipe 111 63mm dia pvc tee 112 63mm dia pvc elbow 113 63mm dia pvc bend 114 20mm dia pvc pipe 115 20mm dia pvc tee 116 20mm dia pvc elbow 117 20mm dia pvc bend 118 20mm x 15mmdia pvc reducer 119 pvc screw down tap heavy type 20mm dia 120 earth work excavation in hard stiff clay and hard rock earth and lowering and laying, jointing of pipes and refilling the trench with excavation soils, well rammed and consolidated after the pipes and specials are laid, jointed and tests including all labour charges etc., complete 121 provision for sanitary pipe line & dispersion arrangements including all charges etc., complete 122 110mm dia pvc pipe 4kg / sqm 123 110mm dia pvc tee 124 110mm dia pvc elbow 125 providing name board charges 126 gst amount for providing service to government contract works for the above construction works. { gst amount is the total gst amount for total overall quoted amount above this row in column bb for all works in this package } 127 construction of threshing floor at kumarsamygoundenvalasuh / o appanuthu estimate amount: rs.8.50 lakhs ( 15m x 15m ) 128 earth work excavation for foundation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 129 cement concrete 1:4:8 ( one cement, four sand and eight hard broken stone jelly ) using 40 mm gauge hard broken granite stone jelly for foundationincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 130 supplying and erecting centering for sides & soffits including supports and strutting up to 3.29m height for plane surfaces in all floors with all cross bracing using mild steel sheets of size 90cm x 60cm and 10 gauge stiffened welded with mild steel angles of size 25mm x 25mm x 3mm for boarding laid over country wood poists of size 10cm x 6.5cm dia spaced at about 90cm center to center etc., complete 131 cement concrete 1:3:6 ( one cement, three sand and six hard broken stone jelly ) using 40 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 132 reilling the excavated earth other than sand including cost, conveyance and filling charges etc., as per standard specifications 133 supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 134 brick work in cement mortar1:5 ( one cement and five sand ) using best quality of country bricks of size 8 3 / 4 x 4 1 / 4 x 2 1 / 4for foundation and basement including curing, etc., complete complying with standard specifiction. 135 cement concrete 1:2:4 ( one cement, two sand and four hard broken stone jelly ) using 20 mm gauge hard broken granite stone jelly for basementincluding dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification 136 plastering with cement mortar 1:5 ( one cement and five sand ) , 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 137 providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 ( one cement, two sand and four aggregate ) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. 138 painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and approved colour over a priming coat including through scrapping, clean removal of dirt and including necessary plaster of pairs putty, wherever required etc complete complying with standard specification 139 supplying and fixing of 0.47mm thick gulvalume sheetfor roofing including all labour charges for fixing neccesary bolt, nuts, screws, j or u bolts etc, 140 supply and fixingmild steel circular, square and rectangular tube section for raft and reepers including cost and conveyance and all labour charges for cutting, welding etc., complete 141 supply and fixing of bitumen pad including cost and conveyance and all labour charges etc.complete 142 towards the cost of providing name boardincluding cost and conveyance of all materials and all labour charges etc., complete...

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

34559349 annual handling of materials at tlc / sub store / thanjavur for the year 2022 2023. loading or unloading including neatly staking of breaker ct, pt etc., panel totally by manual labour. , loading or unloading including staking at proper place of breaker ct, pt etc., panel by using department crane with manual labour. , loading or unloading including neatly staking at properplace of all materials. ( not covered in item no 1 & 2 ) . , re stacking of all materials. , weighingand neatly stacking at proper place for length measuring, marking and stacking of all materials or segregation and staking of tower parts and other materials for verification purpose. , opening, checking, verification repacking and restacking wherever necessary of all materials for verification purpose ( or ) segregating & stacking if tower parts received from other stores / suppliers. , rewinding, length measuring of conductor, earth wire, cable drum by using drum stand or drum device, tripod stand. , counting of all countable materials for verification purpose and checking. , cleaning, unwanted scrub jungles at thanjavur tlc / sub store indoor yard....

National Institute Of Technology - Tamil Nadu

34547022 providing additional electrical power lines, plug points, exhaust fans, and air conditioners to synthetic organic lab (room no 311) in chemistry dept at ojas building. providing additional electrical power lines, plug points, exhaust fans, and air conditioners to synthetic organic lab (room no311) in chemistry dept at ojas building. , wiring , wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. , group b , supplying and fixing of following sizes of medium class pvc conduitalongwithaccessoriesinsurface/recessincluding cutting the wall and making good the same in case of recessed conduit as required. , 25 mm , supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. , 5/6 a switch , 15/16 a switch , 3 pin 5/6 a socket outlet , 6 pin 15/16 a socket outlet , supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. , plastic surface box 6 module , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , 1 or 2 module , 4 module , 6 module , 8 module , supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. , dlp pastic trunking105x50mm and accessories flexible cover85mm 1no, joints for cover85mm width 1no,basejoint 25nos,clips 15nos,separation partition 1no,endcap 2no,internal angles adjustable from 80 degr 120 deg 1no, vdi accessories for internal angles 1no,vdi accessories for external angles 1no, flat angles 1no, vdi accessories for flat angles 1no, flat junctions 1no, flat junctions for specific size tap off to an 80mm wide branch 1no, vdi accessories for juctions 1no, wall crossing 1no, capacity change 1no,capacity change 1no, partition junction 1no, cable ties base 1no.(make: legrand/mk) , dlp pastic mini trunking system32x12.5mm and accessories endcap 1no,internal angles adjustable from 85 degr 95 deg 1no,flat junctions 1no.(make: legrand) , dlp wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface/ recessedas required.(make: finolex/polycab/rr) , 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire , 2 x 10.0 sq. mm + 1 x 10.0 sq. mm earth wire , 4 x 4.0 sq. mm + 2 x 4.0 sq. mm earth wire , 4 x 10.0 sq. mm + 2 x 10.0 sq. mm earth wire , misc civil items , supply and fixing readymade round cement block 1nos labour charges for exhaust fan fixing including mesh wire ,wall cutting bolt nuts fixing andfinishing. , mccb, mcb & dbs , supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (but without mcb/rccb/isolator) , 12 way , double door , supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally used where 3 phase outlets are required.) , 4 way (4 + 12), double door , supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingmcbdbcompletewith connections, testing and commissioning etc. as required. , single pole , double pole , triple pole , 2 4 pole enclosure box only , supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. , supplyingandfixingfollowingrating,doublepole, 240v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40 a , supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), havingasensitivitycurrent30maintheexistingmcbdb complete with connections, testing and commissioning etc. as required. , 40 a , supplying and fixing 20 a, 240 v, spn industrial type socket outlet,with 2poleandearth,metalenclosedplugtop alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. , supplying and fixing of following rating,double pole/single pole,240 volts,isolator/mcb in the existing mcb/db complete with connections,testing and commissioning etc.as required. , single pole 40 63a mcb , double pole 40 63a mcb , supplying and fixing of following rating,three/four pole,415 volts,isolator/mcb in the existing mcb/db complete with connections,testing and commissioning erc.as required. , triple pole 40 63a mcb , four pole 40 63a mcb , supplying and fixing of following amps, 230/415volts, spn/tpn industrial type, socket outlet, with 2/4pole and earth, metal enclosed plug top along with following amps c curve, dp/fp mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. (make: legrand tempra or equivalent) , 6 32a 3p+n+e fp industrial socket , earthing , supplying and laying 6 swg g.i.wireat 0.50 metre below ground level for conductor earth electrode, including connection/ termination with gi thimble etc. as required. , supplying and laying 25 mm x 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminatingwithnut,bolt, spring,washeretc.asrequired. (jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) , supplying and fixing cosmos earthig electrode systems. , cosmos roma 40mm dia 2 mtrs length with moisture enhancer 25 kg. , supply of electrical items , supplying of heavy duty 960 rpm exhaust fan of following sweep, suitable for operation on 230 volts, single phase, 50 hz, ac supply including suitable size louvers as required. , 300 mm (heavy duty)...

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

34545037 supply, transport and erection of gco tower , tower extensions and stringing of panther conductor and earth wire of 110 kv dc line on dc towers by making lilo of pudukottai eid parry 110kv feeder at proposed veerakudi 110 kv ss....

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

34532057 supply, transport and erection of tower and stringing of panther conductor and earth wire for the balance portion of 110 kv dc line on dc towers r by making lilo of vaitheswarankovil poraiyur thiruvenkadu feeder at achalpuram 110kv ss....

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

34407215 stringing of 3 nos. of acsr panther conductor and 1 no. earth wire in the existing 110 kv dc towers from the existing pudhupattu 110 kv ss upto tower location. no. 30 and free arm stringing of 3 nos. of acsr panther conductor from thandrampattu...

Town Panchayats - Tamil Nadu

34208995 construction of public health materials stock room at office campus area in neyyoor town panchayat 1 earth work excavation and depositing on the bank with initial lead and lift of 10 metres and initial lift of 2 metres in hard stiff stiff clay stiff block cotton hard red earth murram, gravel stoney earth and earth mixed with small size boulders and hard gravelly soils (ss 20 b) etc., complete as per standard specification 2 plain cement concrete 1:4:8 (one cement, four sand and eight aggregates) using 40mm iss hbg metal including cost and conveyance of all materials and labour charges for mixing, laying, compacting and curing etc, complete as per ss 3 random rubble masonry in c.m 1:5 (one cement five sand) using best new rough and bond stones including simultaneous pointingabove ground level with the same mortor and cost of all materials andlabour charges etc,complete as per ss..[morth specfication :clause 1000/1400 4 r.c.c.1:1 1/2:3 mix using 20mm iss hbg metal including cost and conveyance and all labour charges for mixing laying finishing and curing etc complete but excluding cost of steel & centering charges etc., complete as per ss 5 supplying and erecting steel centering including necessary supports for plane sufaces in foundation and in all floors for rcc column beams , using mild steel sheets of suitable size 90cm x 60cm and 10 gauge stiffened with including all labour charges etc., complete. 6 supply and fabricating and placing in position of steel reinforcement using mild steel of ribbed tor steel rods for all rcc works as per the design given by the department officers including cost of steel and binding wire and all labour charges for cutting bending and tying and placing in position etc., complete as per ss 7 brick work in cement mortar 1:5 mix using (one cement andfive sand)using best quality of countrybricks of size (8 3/4x41/4x 23/4 ) for foundation including curing cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification 8 plastering with cm 1:3 mix (one cement and three sand), 10mm thick cost and conveyance of all materials finishing, curing and all labour charges etc complete as per standard specification. 9 plastering in cement mortar 1:4 (one cement, four sand) using 12mm thick including cost and conveyance of all materials and labour charges etc, complete as per standard specification. tndss no: 61 v,vi (s4) 10 painting two coats with approvedemulsion paint over one coat of priming coat over cement plastered exposed surface of the reservoir including cleaning, preparing the surface and curing etc., complete and as directed by twad board officers. 11 supply and fixing of mild steel grill works for windows, ventilators, etc including redoxide priming coat and cost of materials and all labour charges etc. complete. 12 painting two coats over new iron workwith ready mixed paintof apprved quality and colour including cost of all materials and labour charges etc complete as per ss 13 floor finishing first quality design ceramic tiles of all colours of sizes 305mm x 305mm x 6mm. laid in cm 1:3 mix 10mm thick and pointing with white cement using 0.4kg/sqm including finishing the joint and pointing flush with tiles surface etc complete 14 wiring with 2x1.5sqmm (22 / 0.3 ) pvc insulated single core unsheathed copper conductor cable of 1100v grade in suitable heavy gauge ms conduit pipe on wall and ceiling with ms accessories with ms switch box and 5a f.t. switch with painting of suitable colour continuous earth wire connection of 14 swg tc wire for light point / fan point for electronic regulator (sd 24) 15 wiring with 2x1.5sqmm (22/0.3) pvc insulated sc unsheathed cu.conductor of 1100 v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories, in flush with wall, with 150mm x 100mm x 113mm tw switch box with 3 mm thick hylem sheet cover for 5 a 3 pin non inter locking cs plug with continuous earth wire connection of 14 swg tc wire and making good of the concealed portion with suitable colour for concealed pvc plug point. (sd 38) 16 supply and fixing of 1200 mm (48) sweep ac ceiling fan complete with stepped electronic 300w regulator, with 1 metre down rod with fan clamp with side plates and cross arm of size 450 mm (18) (sd 107) 17 supply and fixing of single box type 440 w flu fitting complete with copper choke and condensor with tw round blocks on wall or ceiling with flu tube with pvc unsheathed copper leads from terminals to the fitting. (sd 88) ...

Town Panchayats - Tamil Nadu

34122278 providing deep bore well at opposite side of mooventharnagar mutharamman koil and kannupothai colony in aralvoimozhy town panchayat 1 drilling of bore well of size 6 to 8 dia in hard rock formation using hard rock area including inserting of casing pipe, transportation of rig cost of fuel and all labour charges etc complet and as directed by officers concerned 2 supply and delivery of following casing pipes confirming to is specification with isi marking etc complete 180mm pvc plain casing pipe 10ksc 3 180mm pvc slotted casing pipe 10ksc 4 conducting geo physical survey charges 5 supply and delivery of following pipes and specials confirming to is specification with isi marking etc complete50mm upvc column pipe 6 50mm gm gate valve 7 50mm gm non return valve 8 50mm gi elbow 9 50mm gi pipe nipple 10 50mm gi coupling 11 90mm pvc pipe 6ksc 12 4 sq.mm submersible cable 13 supply and delivery of 7.5hp submersible pumpset with a duty condition of 150pm discharge against the head of 125m suitable for 150mm dia bore well confirming to is specification with isi marking etc complete 14 supply and delivery of wall mounting type control panel board consists of ammeter, voltmeter, single phase preventer, over load relay and all accessories suitable for 7.5hp submersible pumpset 15 supply and run of 4 of 6sq.mm pvc insulated sc unsheethed cu.conductor of 1100v in suitable pvcrigid pipe on wall and ceililing with continuous earth wire of 14 swg tc wire painting of suitable wire etc complete ( sd 52 ) 16 supply and run of 4 of 6sq.mm pvc insulated sc unsheethed cu.conductor of 1100v in suitable pvcrigid pipe on wall and ceililing with continuous earth wire of 14 swg tc wire with 32mm gi conduit pipe, painting of suitable wire etc complete ( sd 73 ) 17 earthing as per pwd standard with an earth electrode of 2metre class b gi pipe of dia not less than 32mm complete with necessary masonry work ( sd 234 ) 18 supply and fixing of tneb meter board suitable for 3phase 63a service connection made up of suitable angle iron frame work and supply and fixing of 3nos 63a fuse unit 1no nutral link copper earth flat with inter connection of eb meter to fuse units by 7 / 16 pvc insulater copper wire with earth connection complete ( sd 129 ) 19 labour charges for erection of 7.5hp submersible pumpset in the borewell including fixing and jointing of submersible cable with proper clamps up to starter to the required depth and also fixing of riser pipe to the required depth valves erection clamps pressur gauge up to the exterior wall of the pump room and erection of panel board consists of tpicn switch, ammeter voltmeter three pilot lamps capacitor single phasing preventer water level guard and laying and jointing of cable and twin earthing as per ie rules etc complete and testing the pumpset and trair run for 10 days etc complete 20 earth work excavation and depositing on bank withan initial lead and lift in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth, earth mixed with small size boulders for foundation etc complete 21 cement concrete of mix 1:4:8 ( one cement four sand eight aggregates ) using 40mm gauge hard broken including cost curing etc., complete as per standard specification. 22 brick work in cement mortar 1:5 mix using ( one cement and five sand ) using best quality of iii class country bricks of size ( 83 / 4x41 / 4x 2 3 / 4 ) for foundation including curing cost and conveyance of all materials tosite and all labour charges etc.complete as per standard specification 23 supplying and erection steel centering for sides and soffits including supports and strutting upto 3.29m height for plain surface as rcc slabs, rectangular tee ( or ) elbeams, lintel, bed block stair case waist slab, landing slab, etc., complete as per standard specification 24 reinforcement cement concrete 1:1.5:3 mix ( one cement one and half sand and three aggragate ) using 20mm hbg stone including all cost and conveyance etc complete 25 supply and delivery fabrication of ms doors and windows with outer frame and shutter frame in ms angle in ms angle of size 40 mm x 40 mm x 6 mm with ms flat 25 mm x 25 mmx 6 mm and ms sheet of 18 guage including ventilating arrangements using 20 mm square ms rods with locking arrangements including two coats of approved enamel paint over coat of redoxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete ( size 1.20mx0.90m ) 26 plastering in cement mortar 1:4 ( one cement four sand ) using 12mm thick including cost and conveyance of all materials and labour charges etc, complete as per standard specification. 27 painting the new walls two coats over one coat of priming with best emelsonpaint of approved colour and quality including preparation of surface andfinishing neatly etc., complete complyingwith standard specification and as directed by the department officers 28 painting the new iron works with two coats of ready mixed enamel paint over one coat of priming with standard specification and as directed by the department officers 29 supply, fabrication and placing in position of steel for reinforcement cement concrete including cutting bending and tying etc complete 30 labour charges for linking the pipe line with existing main in proper grade and alignment etc complete. 31 earth work excavation and depositing on bank with an initial lead and lift in hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth, earth mixed with small size boulders for laying of pipe line including refilling the trench with excavated earth etc. complete 90mm pvc pipe 6ksc 32 lowering of following pipes and specials in to trench, laying to proper grade and alignment etc complete. 90mm pvc pipe 6ksc 33 labour charges for linking the pipe line with existing main in proper grade and alignment etc complete....

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

33924811 setting, concreting, tower erection, stringing of panther conductor earth wire, dismantling of existg tower, relese of existing 6 nos. emergency breakdown work of restoration of 110 kv pykara sandynallah karamadai loc 37 and loc 38 in nilgiris...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

33905911 disposal of scrap available at central stores / tantransco / gcc / samayanallur / madurai 1 lot no.1gi earth wire scrap 20000 kgs 2 lot no.2gi earth wire scrap 20000 kgs 3 lot no3 gi earth wire scrap 20000 kgs 4 lot no4 gi earth wire scrap 20000 kgs 5 lot no5gi earth wire scrap 20000 kgs 6 lot no6gi earth wire scrap 20000 kgs 7 lot no7gi earth wire scrap 20000 kgs 8 lot no8gi earth wire scrap 20000 kgs 9 lot no9gi earth wire scrap 20000 kgs 10 lot no10 1 ) gi earth wire scrap18000kgs2 ) opgw scrap148kgs3 ) m.s miscelliance scrap 3535 kgs4 ) rsj cutbit scrap1905 kgs 11 lot no111 ) gi ms tower angle scrap 19000 kgs2 ) empty gas cylinder ( sh ) 8nos3 ) ms / gifitting scrap1095 kgs4 ) gi bolt nut scrap83 kgs5 ) teak wood scrap55 kgs6 ) waste paper scrap928 kgs7 ) cond celling fan3 nos 12 lot no12 1 ) empty steel drum below 6 dia ( sh ) 151nos2 ) cond type writter 1nos3 ) cond volt meter1nos4 ) cond mono block motor 1nos5 ) broken disc head only 450nos 13 lot no13 1 ) condermned jeep 2 nos ( i ) tempo trax jeep tn 59 j 7028 model 1997 ( ii ) tempo trax jeep tn 59 k 8358model 1998 ( all vehicle with out rc book ) 2 ) auto parts scrap 25 kgs3 ) t & p scrap 1 kgs 14 lot no14 1 ) empty barrel 40 / 45 gln cap. ( sh ) 1149 nos2 ) leaky barrel 40 / 45 gln cap. 39 nos 15 lot no151 ) 110 kv sc tower pb type1 set2 ) gcr template2 set3 ) pb+3 mtr extension complete set1 set4 ) gi spring washer 18 mm 938 kgs5 ) gi bolt nut 55 x 18 mm2490 kgs6 ) gi spring washer 12 mm115 kgs7 ) gi stud 25 x 12 mm628 kgs8 ) gi stud 25 x 10 mm401 kgs9 ) gi bolt nut 60 x 18 mm3420 kgs10 ) gi stud 25 x 16 mm 951 kgs11 ) gi bolt nut 55 x 25 mm750 kgs12 ) gi spring washer 10 mm216 kgs13 ) gi bolt nut 30 x 10 mm 500 kgs 16 lot no161 ) gi bolt nut 30 x 183000 kgs2 ) gi bolt nut 35 x 18 2995kgs3 ) ds fittings for zebra3 set4 ) ss fitting for earth wire 7 / 10279 set5 ) mscj earth wire 7 / 10108 nos6 ) repair sleeves for earth wire 80 nos7 ) hand winch2 nos 17 lot no171 ) acsrconductor scrap 9000kgs2 ) aluminium scrap721 kgs3 ) t clump for 3 bus to single kundah20 nos4 ) 14 c x 15 sq.mm single standard18 mtr armord copper cable5 ) sc cable gland size 37mm ( 1 1 / 2 ) 306 nos6 ) 11 kv las clamp 32 nos7 ) aluminium cable useful cut bit 22 kgs ( 4 x 25 sq.mm bit ) 8 ) battery ground faut track kit 1 nos...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

33905903 disposal of scrap available at sub stores / gcc / tantransco / tirunelvely lot no.11 ) acsr conductor scrap9172 kgs2 aluminium cable scrap 9 kgs 2 lot no.2gi / ms tower angle scrap 9814 kgs 3 lot no3 1 ) miscellaneous iron scrap173 kgs2 ) gi fittings scrap388 kgs3 ) gi earth wire scrap1336 kgs4 ) copper cable scrap21 kgs 5 ) gi with porcelin scrap 34 nos 6 ) condemned relay of size5 nos7 ) aluminiumscrap 2 kgs 4 lot no4 condemned jeep1 nomake: bajaj tempo tn 59 j 7027with rc book. modal:1997 5 lot no5sh empty barrel ( 40 / 45 cap ) 340 nos 6 lot no61 ) ls 19 ( g+3 extension ) 8 nos2 ) ah 126 nos3 ) ah 2 stub 26 nos4 ) ah 334 nos5 ) kcr 262 nos6 ) g.c.152 4 nos7 ) pb 01 stub3 nos8 ) hc 798 nos9 ) g.c.150 a 5 nos10 ) gc 1514 nos11 ) ah stub & cleat3 set12 ) 230 kv ah stub & cleat 6 set 7 lot no71 ) 20mm spring washer1750kgs2 ) g.i.bolt & nut 45x25mm5050kgs3 ) g.i.bolt & nut 40x18mm 13400kgs4 ) g.i.bolt & nut 25x12mm300 kgs5 ) g.i.bolt & nut 40x25mm4950kgs6 ) g.i.bolt & nut 50x25mm 1150 kgs7 ) g.i.bolt & nut 60x25mm 3850 kgs8 ) g.i.bolt & nut 300x25mm 1092 kgs9 ) g.i.spring washer 24mm214 kgs10 ) g.i.bolt & nut 30x18mm 3000 kgs11 ) g.i.bolt & nut 35x18mm 7500 kgs12 ) plaste washer 16x3mm 1 kgs13 ) g.i.bolt & nut 80x24mm 243 kgs14 ) g.i.bolt & nut 85x24mm286 kgs15 ) g.i.bolt & nut 25x10mm 300 kgs16 ) g.i.bolt & nut 80x16mm 19 kgs 17 ) g.i.bolt & nut 45x18mm 2562 kgs18 ) g.i.bolt & nut 50x18mm 17390 kgs19 ) g.i.bolt & nut 55x18mm2018 kgs20 ) g.i.bolt & nut 65x18mm98 kgs21 ) g.i.bolt & nut 40x20mm 311 kgs22 ) g.i.bolt & nut 45x20mm3247 kgs23 ) g.i.bolt & nut 45x24mm6950 kgs24 ) g.i.bolt & nut 50x24mm344 kgs25 ) g.i.bolt & nut 70x24mm 57 kgs26 ) g.i.bolt & nut 55x24mm44 kgs 27 ) gi plate washer 24mm 275kgs28 ) 12mm spring washer2174 kgs...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

33869873 sale of scrap available at central stores of gcc i / tantransco / chennaii sale of scrap available at central stores of gcc i / tantransco / ambattur / chennai , g.i / m.s tower angle scrap 40000 kgs , g.i. / m.s tower anglescrap 40000 kgs , g.i / m.s tower angle scrap 43500 kgs. , g.i / m.s tower angle scrap 39198 kgs.. g.i miscellaneous scrap 4980 kgs. , empty m.s. barrels 40 / 45 galn. capacity s.h 1726 nos. , acsr conductor cut bits scrap 49721 kgs.aluminium cable scrap 17 kgs..g.i with aluminium scrap 553 kgs.aluminium scrap 548 kgs. , g.i earth wire cut bits scrap 38315 kgs.instrumentation scrap 3 kgs m.s miscellaneous scrap 4580 kgs.. g. iwith porcelain scrap 4188 kgs.auto parts scrap 29 kgs condemned type writing machine 1 no. empty steel drum 3 to 6 dia 9 nos. , condemned 8 mva 33 / 11 kv power transformer, without oil. make.vei , sl no.8300 1 no....

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

33705574 execution of contract towards extension of supply and other works in vallioor sub division at valliyoor division/tirunelveli edc sl. no. item description 1 normal ground excavation of pole pits (1.25m * 0.5m*1.5m) for 7.32m, 7.5m, 8m, 8.23m poles 2 normal ground erection of 7.32m, 7.5m, 8m, 8.23m poles 3 rocky ground (medium) excavation of pole pits (1.25m * 0.5m*1.5m) for 7.32m, 7.5m, 8m, 8.23m poles 4 rocky ground erection of 7.32m, 7.5m, 8m, 8.23m poles 5 hard rock requiring blasting and chisseling excavation of pole pit (1.25m * 0.5m*1.5m) for 7.32m, 7.5m, 8m, 8.23m poles 6 hard rock requiring blasting and chisseling erection of 7.32m, 7.5m, 8m, 8.23m poles 7 normal ground excavation of pole pits (1.25m * 0.6m*1.83m) for 9m & 9.14m poles 8 normal ground erection of 9m & 9.14m poles 9 rocky ground excavation of pole pits (1.25m * 0.6m*1.83m) for 9m & 9.14m poles 10 rocky ground erection of 9m & 9.14m poles 11 hard rock requiring blasting and chisseling excavation of pole pit (1.25m * 0.5m*1.5m) for 9m & 9.14m poles 12 hard rock requiring blasting and chisseling erection of 9m & 9.14m poles 13 normal ground excavation of pole pits (1.25m * 0.6m*2.19m) for above 9.14m poles & 36 length rs joists 14 normal ground erection ofabove 9.14m poles & 36 length rs joists 15 rocky ground excavation of pole pits (1.25m * 0.6m*2.19m) for above 9.14m poles & 36 length rs joists 16 rocky ground erection ofabove 9.14m poles & 36 length rs joists 17 hard rock requiring blasting and chisseling excavation of pole pit (1.25m * 0.5m*1.5m) for above 9.14m poles & 36 length rs joists 18 hard rock requiring blasting and chisseling erection of above 9.14m poles & 36 length rs joists 19 normal ground excavation of pole pits (1.25m * 0.6m*2.19m) for 42 length rs joists 20 normal ground erection of42 length rs joists 21 rocky ground excavation of pole pits (1.25m * 0.6m*2.19m) for 42 length rs joists 22 rocky ground erection of 42 length rs joists 23 hard rock requiring blasting and chisseling excavation of pole pit (1.25m * 0.5m*1.5m) for 42 length rs joists 24 hard rock requiring blasting and chisseling erection of 42 length rs joists 25 transporting of poles from road side to pole pit upto 2km 7.32m, 7.5m, 8m, 8.23m rcc pole 26 transporting of poles from road side to pole pit upto 2km 9m, 9.14m rcc/psc pole 27 transporting of poles from road side to pole pit upto 2km rsj 36 pole 28 transporting of poles from road side to pole pit rsj 42 and above 29 loading and unloading of poles 7.32m, 7.5m, 8m, 8.23m rcc pole 30 loading and unloading of poles 9m, 9.14m rcc/psc pole 31 loading and unloading of poles rs joists, tubular & rail pole (above 9.14m) 32 concreting of poles as per board standards (2*2*5). the materialsuch as cement, sand, jelly, etc., have to be supplied by the contractor (cement concrete mix 1:4:8 using 40mm hard broken stone including cost of labour charges.for placing transporting of sant,jally,from box and water curing for 14 days etc,.complete) 33 coping of pole (0.6m*0.6m*0.35m) 34 concreting of stay (o.3m * 0.3m * 1.5m) including materials 35 coil earthing per pole & pole earthing 36 normal ground excavation of stay pit (1.00m * 0.5m*1.5m) with transporting of materials to site (for stay set) 37 normal ground erection of stay set 38 rocky ground (medium) excavation of stay pit (1.00m * 0.5m*1.5m) with transporting of materials to site (for stay set) 39 rocky ground erection of stay set 40 hard rock requires blasting & chisseling excavation of stay pit (1.00m * 0.5m*1.5m) with transporting of materials to site (for stay set) 41 hard rock requires blasting & chisseling erection of stay set 42 loadingand unloading charges of oil drums (with oil) 43 loadingand unloading charges of oil drums (withoutoil) 44 loadingand unloading charges of conductor drum, cable drum 45 loadingand unloading charges of line materials 46 loadingand unloading charges of metering set 47 11kv lines (pin point) fixing of v & channel cross arm 5.5 including transporting of materials from road side to site 48 11kv lines (cut point) fixing of v & channel cross arm 5.5 including transporting of materials from road side to site 49 11kv lines (pin point) fixing of v & channel cross arm 4.5 including transporting of materials from road side to site 50 11kv lines (cut point) fixing of v & channel cross arm 4.5 including transporting of materials from road side to site 51 11kv lines (pin point) fixing of v & channel cross arm 3.5 including transporting of materials from road side to site 52 11kv lines (cut point) fixing of v & channel cross arm 3.5 including transporting of materials from road side to site 53 11kv lines fixing of lt 3phase cross arm including transporting of materials from road side to site 54 11kv lines fixing of lt 1phase cross arm including transporting of materials from road side to site 55 11kv lines fixing of ht lt ti fitting including transporting of materials from road side to site 56 11kv lines erection of ht side arm with stud including transporting of materials from road side to site 57 11kv lines erection of lt side arm with stud including transporting of materials from road side to site 58 11kv lines fixing of insulator (per location) including transporting of materials from road side to site 59 11kv lines fixing of 11kv disc including transporting of materials from road side to site 60 11kv lines fixing of tapping channel cross arm including transporting of materials from road side to site 61 ht lines (33kv) stringing, sagging, binding including transporting of materials from road side to site for dog conductor (1span/wire) 62 ht lines (33kv) stringing, sagging, binding including transporting of materials from road side to site for 7/4.09 acsr conductor (1span/wire) 63 ht lines (33kv) line clear works for dog conductor (1span/wire) 64 ht lines (33kv) line clear works for 7/4.09 acsr conductor (1span/wire) 65 11kv lines stringing, sagging, binding including transporting of materials from road side to site for 7/2.59 acsr (1span/wire) 66 11kv lines stringing, sagging, binding including transporting of materials from road side to site for 7/3.35 acsr (1span/wire) 67 ht lines stringing, sagging, binding including transporting of materials from road side to site for 7/4.09 acsr (1span/wire) 68 11kv lines line clear works for for 7/2.59 acsr (1span/wire) 69 11kv lines line clear works for for 7/3.35 acsr (1span/wire) 70 11kv lines line clear works for for 7/4.09 acsr (1span/wire) 71 lt lines stringing, sagging, binding including transporting of materials from road side to site for 7/2.59 acsr, 7/2.50aaac 72 lt lines stringing, sagging, binding including transporting of materials from road side to site for 7/3.35 acsr, 7/3.15 aaac 73 for lt line clear works for for7/2.59 acsr, 7/2.50aaac (1span/wire) 74 for lt line clear works for for 7/3.35 acsr, 7/3.15 aaac (1span/wire) 75 guarding per span length spilt neutral guarding 76 guarding per span length flat guarding (2 wires) 77 guarding per span length flat guarding (4 wires) 78 guarding per span length flat guarding (6 wires) 79 guarding per span length cradle guarding (fixing of x arm lacing ) 80 guarding per span length fixing of one earthing device with stud 81 erection of transformer/dismantling upto 200kva 82 erection of transformer/dismantling upto 250kva 83 erection of transformer/dismantling upto 500kva 84 erection of centre support (including concrete) 85 erection of metering set 86 erection of feeder cable with open type fuse unit per feeder 87 erection of feeder cable with open type fuse unit for each addl feeder 88 erection of feeder cable bus bar arrangement with open type 89 loading & unloading of distribution transformer below 250kva 90 loading & unloading of distribution transformer 250kva 91 loading & unloading of distribution transformer 500kva 92 plinth work for 500kva dt with construction material 93 fabrication ,erection and excavation for centre support etc for 250 /500 dt including transporting 94 tube light erection 1*40w tube light complete set (including transport) 95 tube light erection for sv lamp and mercury lamp complete set (including transport) 96 tube light erection for cfl lamp complete set (including transport) 97 painting of sc number including painting 98 tube light 72w led erection 99 manufacturing of clamps 50*8 mm 100 manufacturing of clamps 65*10 mm 101 alteration of clamps 102 street light switching point arrangement 103 drilling / less than 23mm holes per hole /slotted holes 104 cutting of channel 105 cutting of flat 106 cutting of angle 107 rsj pole cutting 108 tubular pole cutting 109 rail pole cutting 110 fabrication of lightning arrestor frame 111 lt changing of pin point to cut point 112 ht changing of pin point to cut point 113 erection of service connection materials 1ph service 114 erection of service connection materials 3ph service 115 dismantling of deteriorated poles with concrete in damaged condition including grill separation etc., 116 dismantling of poles without concrete in damaged condition including grill separation etc., 117 providing jumpering at cut point 118 complete replacement of worn out earth wire per structure 119 labour for manufacturing of open type fuse unit (materials supplied by board) 120 manufacturing of hg fuse stool incl. materials 121 tree clearence in ht or lt location for ordy. tree clearence and throng bushes & trees 122 tree clearence in ht or lt location for coconut trees 123 tree clearence in ht or lt location for palmrah trees 124 painting double pole transformer structure materials (double coat) (including cost of paint) 125 painting pole (colour washing with distember) 2 nos (including cost of paint) 126 painting for transformer only (double coat with paint) 127 numbering of poles with backround colour paint 128 numbering of distribution transformer (painting and writing of name board size 1 1/4*1 incl cost of paint & board and ms sheet 129 writing in seating channel (paint to be supplied by contractor) 130 painting of rcc strcucture poles all metal parts, snowcem & aluminium paint to be supplied by contractor 131 painting of rsj structure poles & metal parts aluminium paint to be supplied by contrcator 132 set right of leaning ht pole/lt pole including x arms, ti fittings 133 transformer structure erection excavation of structure pole pits ( 2nos) 134 transformer structure erection erection of structure poles ( 2nos) 135 transformer structure erection excavation of stay pits(4nos) 136 transformer structure erection erection of stay set (4nos) 137 transformer structure erection concreting of structure poles incl.materials mass concrete with coping (2 poles) 138 transformer structure erection concreting of stays (4nos) incl.materials 139 erection of structure materials top channel 140 erection of structure materials transformer seating channel and belting angle 141 erection of structure materials ab switch (complete) 142 erection of structure materials hg fuse (complete) 143 erection of structure materials jumpering 144 erection of structure materials ht las 145 erection of structure materials lt las 146 erection of structure materials transformer lt cable wiring / lt bus bar 147 erection of structure material erection of lt open type fuse unit including cablejumbering up to the line including cutting welding bending ,fabrication etc 148 earthing system excavation of 4 nos. earth pits 149 earthing system excavation of earth wire trenches and paving of earth wire, erection of 4 nos. earth pipe and giving earth connection, earthing of all metal parts, las etc., including central connection 150 earthing system mason works with bricksforearth pits4 nos (cementsupplied by contractor) 151 earthing system painting of transformer structure 2 coats incl.paint 152 earthing system painting with distember paint on poles with paint cost 153 earthing system spreading yard jelly and cut stone and bricks including material 154 earthing system writing of name board and target board 155 earthing system transporting of structure materials abs,hg fuse,cable etc except pole 156 earthing system fixing of danger board ( labour only) 157 erection of tapping structure excavation of structure pole pit. (2nos) 158 erection of tapping structure erection of structure pole. (2nos) 159 erection of tapping structure excavation of stay pit (2nos) 160 erection of tapping structure erection of stay set (2nos) 161 erection of tapping structure concreting of structure poles including materials mass concrete with copping (2nos) 162 erection of tapping structure concreting of stay (2nos) 163 erection of structure materials top channel 164 erection of structure materials ab switch (complete) 165 erection of structure materials assemble, operating pipe fixing etc., fixing of cross bracing 166 earthing system excavation of 1 no. earth pits excavation of earth wire trench and paving of earth wire, erection of 1 no. earth pipe and giving earth connection, earthing of all metal parts, for tapping structure. 167 earthing system mason works with bricks for earth pit (including material) 168 colour coating on poles with iron materials including paint and distember 169 transporting of 42 twin rsj pole from roadside pole pit 170 fabrication of 42 twin rsj pole, materials supplied by board. 171 excavation & erection of twin 422 fabricated rsj pole 172 concreting of 42 twin rsj pole 173 concreting of 42 twin rsj pole 174 resagging of various conductor (please mention in percentage of respectie conductor) 175 dismantling of 7.5m /8m pole with out damage 176 dismantling of 9.14m pole/ rsj with out damage 177 dismantling of stay set complete 178 replacement of detoriated stay rod 179 replacement of rsj/tubular poles below 30 feet 180 replacement of rsj/tubular poles aove 30 feet 181 dismantling of detoriated cables of various size(95,120,185 sq.mm) from dt,lt bushing to lt open type clamp anderection of suitable lug at both ends 182 replacement of new 10 earthpipe replacing the corroded earth pipe and renewal of earthing including burying , looping and binding 183 mass concrete for poles on the line ( all materials including cementratio 1:2:4) ( 1 loc ( 0.72 m3) (0.65*0.65*1.65 m,0.6*0.6*0.35 cum) 184 sleeveconcrete for poles on the line ( all materials including cementratio 1:2:4) ( 1 loc ( 0.202 ) (0.5*0.45*0.9m) 185 providing of spacers in lt lines 186 hiring of jcb 187 hiring of crane 188 exceeding 1 hour for every hour 189 transporting of charges of dt / line materials using private vehicle upto 20 km( up and down) 190 beyond 20 km for every km 191 single pole structure erection excavation of structure pole pit 3’ x 6’ by using jcb or manual 192 single pole structure erection transportation of pole from road side to pole pit by using jcb or manual 193 single pole structure erection erection of poles by using jcb or manual 194 single pole structure erection excavation of stay pit by jcb or manual (2nos) 195 single pole structure erection erection of stay set complete (2nos) 196 single pole structure erection mass concreting for structure 197 singple pole structure erection stay concrete (2nos) 198 single pole structure erection erection of structure materials tapping channel 199 single pole structure erection erection of structure materials transformer bed stucture 200 single pole structure erection erection of ab switch 201 single pole structure erection erection of h.g. fuse (3nos) 202 structure earthing complete with 3 pits and earth loops 203 singple pole structure erection fixing of mcd box 204 singple pole structure erection ht las fixing (3nos) 205 singple pole structure erection lt las fixing (3nos) 206 singple pole structure erection ht jumpering complete 207 singple pole structure erection painting of all clamps and other iron materials and painting of structure pole 208 singple pole structure erection ltcable arrangement 209 singple pole structure erection fixing of danger board 210 dismantling of other line materials (please mention in percentage for respective line material errection works) ...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

33656684 works contract for execution of agri works in krkn section in alangulam sub division of rajapalayam division works contract for execution of agri works in krkn section in alangulam sub division of rajapalayam division sl. no. item description 1 works contract for execution of agri works in krkn section in alangulam sub division of rajapalayam division 2 loading & unloading of9 mtr psc poles 3 transporting of9mtr psc poles 4 excavation of9.0 mpsc poles pit in normalground 5 erectionof9mtr psc poles 6 loading & unloading of8.0 m psc poles 7 transporting of8.0 m psc poles 8 excavation of8.0 m psc poles 9 erectionof8.0 m psc poles 10 erection of 3 1/2 v x arm 11 erection of tapping channel x arm 12 erection lt 3 phase x arm 13 lt single phasex arm 14 erection of ht ti fitting 15 exavation of stay bit rockey ground 16 erection ofstay set complete 17 erection of guarding arrangement 18 paving & stringing of 7/2.50 mm aaac conductor 19 earthing of pole 20 concreting of poles (material supplied by contractor) 21 dismantling of 8.0 m psc pole 22 dismantling of stay set scrap 23 dismantling of lt sq/3q xarm 24 dismantling of7/2.59 ,7/2.50 mm conductor 25 resagging of lt line for all size 26 split neutral guarding 27 transporting of line material from store to site 28 loading and unloading of 9.0 m pscsquare pole 29 transport of 9.0 mtr psc square polefrom stores to site 30 excavation of pole pit (9.0mtr) square pole 31 erection of poles (9.0 mtr) square pole 32 concreting of structure pole 33 coping of pole 34 erection of single pole tc set suitable for16 kva dt 35 erection of lt protection kit 36 erection of hg fuse, 11 kv solid core type 37 erection of 11 kv, 200 amps, single break gos 38 jumpering 39 vertically mounted 11 kv hg fuse unit with insulator 40 erection of lt las 41 erection of feeder cable with open type fuse unit per feeder 42 fixing of tapping channel x arm 43 fixing of ht it fitting 44 masanory work for each earth pit for 2 nos earth trough and concrete. 45 excavation of 2 nos earth pits for structure 46 excavation of earth wire trenches, paving of earth wire, erection of earthing pipe, giving connect 47 assemble, operating pipe fixing etc., fixing of cross bracing 48 painting pole (colour washing with emulsion on labour only) (double coat) 49 painting of transformer structure (double coat) 50 loading and unloading of dt 16 kva 51 erection of transformer 16kva 52 excavation and erection of stayset completed 53 transporting of dt structure materials / single pole tc set/ hg fuse except pole 54 transporting of distribution transformer 16kva 55 alteration of clamp 56 drilling of holes ...

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

33614841 earth work excavation, stub setting, concreting and earthing of towers, supplying of stub & cleat and +3 extension, erection of towers, hoisting of insulators, lowering and restringing of panther conductor and earth wire and supply of necessary hardware materials for periyar kayathar suriliyar 110 kv dc line in 2 nos gcr+3 tower at loc:147a and loc.148a for the vertical clearance of rajapalayam to therkuvenganallur road => limited...

Rural Development And Panchayats Department - Tamil Nadu

33592923 agamt ii 2021 22 infra public utilities works at singampunari block in sivagangai district package no. 123 1 construction of anganwadi building pu middle school at s.mampattivillagein s.mampatti panchayat 2 earth work excavation for foundation in all soils such as red earth ,hard stiff clay soil, stiff black cotton soil, hard redearth,shales, murrams, gravel,hard rock not requiring blasting ete complete., 3 sandfilling in to the basement including cost and conveyanceto the site and all labour charges for filling as per standard speecifications 4 cement concrete 1:4:8 mix usin 40 mm hbg metal inculding cost and coveyance of all materials to site including labour for mixing laying,curing etc complete. 5 brickwork in cement mortar 1 : 5 mix using new ii class bricks including cost and conveyance of all materials to site and labour charges etc complete. 6 rcc 1:1.5:3 mix using20mm hbg metal including all labor charges etc complete 7 supplying&fabrication of steel including all labor charges etc complete 8 supplying and erection centering for sides and soffits inculding necessary supports and structing for plain surfaces such as rcc slab,lintel,beam coloum,sunshade etc complete., 9 plastering with cement morter 1:5 mix 12 mm thick inculding cost and conveyanceof all materials to site and labour charges for curing etc 10 plastering with cement morter 1:3 mix 10 mm thick inculding cost and conveyanceof all materials to site and labour charges for curing etc 11 provision for cupboard cuddapah slab50 mm tkinclding supply and fixing etc 12 finishing the top of roof with one course of pressed tiles of size 23 cm x 23 cm x 2 cm laid in cement mortar 1:3 (one cement and three sand) 12mm thick mixed with water proofing compound conforming to i.s. at 2% by we 13 ceramic tiles flooring laying with new ceramic tiles of size 300x300x6 mm laid in c m 1:3 inculding cost of white cement and labour charges etc 14 dadooing of walls with glazed tiles of size 15 cm x15cmx6mm laid in cm 1:2, 10mm thick & pointing with white cement using 0.4kg/cm2 15 fabrication and supply of mild steel door including all labour charges etc complete. 16 door 0.90 x 2.10 m 17 door 0.75 x 1.20 m 18 fabrication and supply of mild steel window including all labour charges etc complete. 19 window1.20 x 1.30 m 20 ventilator0.90 x 0.45 m 21 distembering two coats with best approved distemberincluding cost and conveyance of all materials to site and all labour charges etc complete 22 cement painting two coats with best approved quality and colourpaint over one coat of base coat including cost and convyance of all materials to work site and labour charges etc., complete. 23 painting with enamel paint two coat of new iron works such as steel doors ,windows ,ventilators, etc., with best approved first quality of synthetic enamel paint of approved colour over the existing priming coats,ete. 24 wiring with 2 x 1.5 sq.mm (22 / 0.3) pvc insulated sc unsheathed copper conducutor cable of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories inflush with wallwith3 mm thick hylum sheet cover withtw boxand 5 a ft switch with continuous earth connection of 14 swg tc wire for making good ofthe concealed portion with suitable colour for pvc concealed light point / fan point (for electronic regulator) sd 22 25 wiring with 2 x 1.5 sq.mm (22 / 0.3) pvc insulated sc unsheathed copper conducutorof 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories inflush with wallwith150 mm x 100 mm x 113 mm tw switch boxwith3 mm thick hylum sheet cover for 5 a 3 pin non interlocking cs plugwith continuous earth wire connection of 14 swg tc wire for making good ofthe concealed portion with suitable colour forconcealed pvcplugpointsd 36 26 supply and run of 2 of 1.50 sq.mm (22/0.30) pvc insulated sc unsheathed copper conductor of1100 v grade on 7/20gi bearer wire for service connection mains sd 62 27 supply and run of 2 x 1.5 sq.mm(22 / 0.30) pvc insulated sc unsheathed copper conductor of1100 v grade in 25 mm dia gi pipe( class b ) suitably bent at both ends with necessary angle iron upright and end supports for mains. sd 67 28 supply and fixing of wt bulk head fitting with guard ( philips / bajaj / crompton / k lite ) suitable for incandescent lamp with 60 w bulb.sd 80 29 supply and fixing of cfl bulb fancy class 11w sd 80 30 supply and fixing of 16 amps dpic switch of 500 v with fuse and neutral (side handle) on suitable tw box pwd earthingsd 135 31 supply and fixing of tneb meter board suitable for 32a single phase service connection with 32a fuse unit(500v) 32 a neutral link and earth link on tw plank of size 375mmx300x13mm with supporting tw reepers of 1 thick an either side with painting with suitable bolt and nuts for fixing the tw plank on wall earth connection and inter connection with 7/20 pvc insulated copper wire from eb meter to fuse unit (sd125) 32 supply and fixing of 1200mm (48) ac ceiling fan complete with stepped electronic 300 w regulator with 300mm down rod on the existing clamp. (sd no. 110) ( isistd company) 33 provision for water supply arrangements sub estimate 34 supply ,delivery of hdpe tank of 1000ltrcapacity with isi mark 35 construction of cycle stand hr.sec.school at aniyampatti villagein vagutheluvanpatti panchayat 36 earth work excavation in all classes of soils such as hard stiff clay.stiff block hard red earth, shales, murram, gravel, stoney earth expect hard rock requiring blassing and depositing on bank with all leads and lifts and all incidental charges such as storing shuddering and balling out water in necessary etc., completed for foundation as ss 20b. 37 filling with clear river sand in foundation including cost & conveyance to site and labour charges for watering raming and all other incidental charges etc., complete. 38 cement concrete 1:4:8 mix using 40mm iss hbg metal including cost & conveyance of all materials to site including labour for mixing laying compacting curing concrete and all other incidental charges etc., complete 39 brick work in cm 1:5mix using country bricks ground moulded of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. 40 cement concrete 1:1:5:3 (one cement two sand and four jelly) using 20mm h..g. jelly for all r.c.c. items of works excluding cost of reinforcement and fabricating charges, centering and shuttering but including curing but providing fixtures like fanclamps in the r.c.c. floro or roof slabs wherever necessary and bearing surfaces of walls, sides and bottom of the slabs, beams etc., complete 41 centering and shuttering for r.c.c works including cost and conveyence of all charges etc. complete. 42 supplying and fabricating, placing in position m.s. or r.t.s for all reinforced cement concrete works as per the design given including the cost of steel and binding wire in all floors etc., complete complying with standard specification. 43 plastering with cement mortar 1:5 12mm thick including cost & conveyance of all materials to work site i all other charges etc., completed. 44 cement concrete 1:2:4 mix using 20mm iss hbg metal including cost & conveyance of all materials to site including labour for mixing laying compacting curing concrete and all other incidental charges etc., complete 45 supplying& fixing of gi pipe 65mm dia pipe for purlings in grt gi sheet roofing including all labour charges etc complete 46 supplying &fixing of hollow pipe truss of size 0.60x0.40x4mm for gi sheet roofing including all labour charges etc complete 47 supplying &fixing of hollow pipe of size 0.50x0.25x3mm for gi sheet roofing including all labour charges etc complete 48 supplying and fixing of grtsheet 1.6mm thick roofing sheet including all labour charges etc complete 49 painting with plastic emulsion painttwo coats withincluding cost of all materials and labour charges etc., complete as per standard secification. 50 construction of girls toilet building govt hr sec school @ aniyampatti village in vagutheluvanpatti panchayat 51 earthwork excavation for foundation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick, well rammed and consolidated and depositing the surplus earth within the compound in places shown by the departmental officers with initial lead and lift etc.,including levelling the sites complete complying with standard specifications and as directed. 52 cement concrete 1:4:8 mix using 40mm gauge hand broken hard granite stone jelly for foundation including dewatering if found necessary and laid in layers of not more than 15cm thick, well rammed etc., complete complying with standard specification. 53 fillling in basement with excavated earth in layers of not more than 15cm thick,well rammed, watered and compacted, complying with standard specification etc., complete. 54 supplying and erecting centering for sides and soffits including supports and strutting upto 3.29 m high for plane surfaces such as rcc slabs, rectangular beams, tee or ell beams, lintels, bed blosks. staircase waist and landing slabs, landing beams, canopy etc., in all floors with all cross bracings using mild steel sheets of size 90cm * 60cm and bg 10 stiffened with welded mild steel angles of size 25mm * 25mm * 3mm for boarding laid over countrywood joists of size 10cm * 6.50cm spaced at about 90cm centre to centre and supported by casuarian props of 10cm to 13cm dia spaced at 75cm centre to centre etc., complete and as directed. 55 supplying, fabricating and placing in position mild steel/ribbed tor steel rods for all rcc works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 56 reinforced cement concrete 1:1.5:3 mixusing 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering, shuttering and cost of reinforcement grills placed in position, but including laying, vibrating, curing and finishing, fixing fan clamps in the rcc floor and roof slab works wherever necessary and bearing surfaces of the wall at the sides and bottom of the slab, beams shall be finished smooth with cement mortar 1:3 (one cement and three sand ) and kraft paper laid without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers. 57 special ceiling plastering and finishing all the rcc exposed surfaces such as rcc slabs, sunshades, canopies, staircase steps, landing slabs, etc. with cement mortar 1:3 (one cement and three sand) 10mm thick and including hacking the surfaces and providing necessary cem,ent mortar nosing beading as per size, specification wherever necessary using the same mix as directed by the departmental officers etc.,complete complying with standard specification. 58 brick work in cement mortar 1:5 (one cement and five sand) using second class country bricks of size 23cm x 11cm x 7cm for the following including curing etc., complete complying with standard specifications.(masonry projections wherever necessary for obtaining required elevation shall be done without extra cost). 59 plastering with cement mortar 1:5 (one cement and five sand)12mm thick in all floors complying with standard specifications. 60 paving the floor with scratch proof ceromic tiles of size 305x305x6mm including cost and conveyance of all materials to site and all labour charges etc complete 61 providing granolithic floor finish with cc 1:2:4 using 10 12mm hbg jelly including cost and conveyance and all labour charges etc. 62 painting two coats using ist quality readymix enamel paint of approved colour over new iron work including cost and conveyance and all labour charges etc. 63 distembering two coats with best approved distemberincluding cost and conveyance of all materials to site and all labour charges etc complete 64 exterior emulsion painting two coats with best approved quality and colourpaint over one coat of base coat including cost and convyance of all materials to work site and labour charges etc., complete. 65 supplying and fixing in position best indian make white glazed earthen ware oriya type indian water closet including cost and conveyance and all labour charges etc. 66 supplying and fixing in position best quality make white glazed wash basin including cost and conveyance and all labour charges etc. 67 supplying and fixing in position best indian make european water closet including cost and conveyance and all labour charges etc. 68 towards the cost of steel door of size 1mx1.80 m including all charges etc. 69 door 1.10x 1.80m 70 door 0.75x 1.80m 71 gst amount for providing service to government contract works for the above construction works. { gst amount is the total gst amount for total overall quoted amount above this row in column bb for all works in this package} ...

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

33583574 earthwork excavation, providing foundation, supply and erection of 110 kv dc tower, stringing of 3 nos. of acsr panther conductor and one number of gi earth wire for replacement of deteriorated tower at location no.52/56 in 110 kv kadapperi – korattur i & ii dc feeder near malayambakkam in chennai south operation circle ...

Rural Development And Panchayats Department - Tamil Nadu

33532855 civil works 3 nosin merkanamblock sl. no. item description 1 construction ofteachers toilet@ pues, brammadesam panchayat 2 earth work excavation for foundation in all classes of soils and sub soil to full depthexcept in hard rock requiring blasting but inclusive of shoring struttingif required forthe sides of foundation. 3 supplying and filling in foundation and basement with good sand in layers not more 15 cm thick including ramming, watering and compacting etc.complete complying to standard specification 4 cement concrete 1:4:8 mix using 40 mm hbg metal for foundaion including watering wherever necessary and laid in layers of not more than 15cm thick. compacting etc., complete complying with standard specifications and as directed by the departmental officers etc, complete. 5 brick work in cm 1:5 mix using country bricks ground moulded of size 23 x 11 x 7 cm for the following including curing etc., complete complying with standard specifications. 6 supplying and fabricating and placing in position ms steel or ribbed for steel for all reinforced cement concrete works as per the design given including cost of steel and blinding wire all floors etc., complete complying with standard specification. 7 supplying and erection centering for sides and soffiots including necessaary supports and strutting as directed by the departmental officers lintels, staircase waist slabs, landing slabs, landing beam, portico beam etc.) 8 rainforcement cement concrete 1:1.5:3 using 20 mm iss hbg metal for all rcc item of works excluding cost of reinforcement and fabricating charges, centering and shuttering but icluding curing and providing fixtures like fan clamps in the rcc floor or roof slabs wherever necessary and bearing surfaces of walls, sides and bottom of the slabs, beams, etc., shall be finished smooth with cement mortar 1:3, 12mm thick and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications. 9 floor finishing with anti skid tiles of size 300 x300 x 6 mminckluding cost and conveyance of all materials and labour charges , etc, complete. 10 dadooing walls with colour designed ceramic glazed tiles of size300 mm x 200 m x 6 mmof any shape and quality laidcement mortor 1 : 2over 10 mm base layer in all floors and the top pointed with the white cement 0.40 kg mixed with the same colouring pigments etc complete 11 ceiling plastering with cement mortar 1:3 mixto 10 mm thick for r.c.c. items including cost and conveyance of all materials to site and all labour charges etc complete 12 plastering with cm 1:5, 12mm thick over the cement concrete for floor finish including curing etc., complete complying with standard specifications and as directed by the departmental officers. 13 distempering two coat with priming coat and two coat with oil bound distemper over cement plastered surface, ceiling and other new surface including cleaning preparing the surface etc, complete. 14 painting two coat approved exterior emulsion over the plastered surface including cost and all other charges etc., 15 painting two coats of new iron works such as steel doors, windows,ventilators, window bars, balustrades etc., with best approved first quality of synthetic enamel paint of approved colour over the existing priming coats, etc., complete complying with standard specifications and as directed by the departmental officers. 16 cost and supply of steel doors and windows of specified gauge and thicness as directed by the departmental offcers, including all labour charges and fabrication charges etc, complete. 17 cost and supply of steel doors and windows of specified gauge and thicness as directed by the departmental offcers, including all labour charges and fabrication charges etc, complete. 18 water supply arrangements 19 provision forname board and photographic charges 20 construction of anganwadi building @ brammadesam panchayat 21 earthwork excavation in all classes of soils except hard rock rerqurining blasting and depositing on bank with all leads and lifts as per ss20a including cost of all labour materials, tools, equipments and all incidentail charges and sheeting, shoring.km0/0 0/900 22 cement concrete 1:4:8 mix using 40 mm hbg metal for foundaion including watering wherever necessary and laid in layers of not more than 15cm thick. compacting etc., complete complying with standard specifications and as directed by the departmental officers etc, complete. 23 refilling in basement with excavated earth in layers of not more than 15 cm thick , well watered,rammed and consolidated complying with standard specification etc complete . 24 supplying and m sand filling inbasement withconveyed gravel in layers not more than 15 cm thick , well ramed and consolidated complying with standard specification 25 supplying and filling inbasement with filling sand in layers not more than 15 cm thick , well ramed and consolidated complying with standard specification 26 supplying and erection centering for sides and soffiots including necessaary supports and strutting as directed by the departmental officers lintels, staircase waist slabs, landing slabs, landing beam, portico beam etc.) 27 superstructure 28 forsunshade & platform 29 for lintel, beam and slab, roof level beam 30 supplying, fabricatung and placin g in position of rts or ms rod for all reinforced cement concrete works as per design given including cost of steel and binding wire in all floors etc,complete complying with standard specification 31 rainforcement cement concrete 1:1.5:3 using 20 mm iss hbg metal for all rcc item of works excluding cost of reinforcement and fabricating charges, centering and shuttering but icluding curing and providing fixtures like fan clamps in the rcc floor or roof slabs wherever necessary and bearing surfaces of walls, sides and bottom of the slabs, beams, etc., shall be finished smooth with cement mortar 1:3, 12mm thick and with kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications. 32 brick work in cement mortor 1 : 5 mix using country bricks of size 22 x 11 x 7 cm including cost and conveyance of all materials and labour charges etc complete . 33 plastering with cement mortor 1:5,12mm thick including cost and conveyance of all materials and labour charges including curing etc., complete complying with standard specificationas directed by the departmental officers 34 plastering with cement mortor 1:3 ,20mm thick including cost and conveyance of all materials and labour charges including curing etc., complete complying with standard specificationas directed by the departmental officers 35 special ceiling plastering and finishing all rcc exposed surfaces such as rcc slabs, canopies, sunshades, landing slab beams ,etc with cementmortor 1:3, 10mm thick (one cement and three sand)including cost and conveyance of all materials and labour charges etc complete as directed by the departmental officers etc complete complying with standard specification. 36 paving the wall andfloor with best quality stain free nano polishvetrifiedtiles of size 60 cm x 60 cm x 8 mm any approved colour and sizeshape and quality laid in cement mortor 1 : 3 to 20 mm thick in all floors and the top pointed with the white cement 0.40 kg mixed with the same colouring pigments etc complete 37 paving the wall and floorwith anti skid tiles of any colour and any size laid incm 1 :2 , 20 mm thick andpointing with white cement 0.40 kgper sqm mixed with colouring pigment to match the colour of the tiles including finishing the joints neatly complying with the standard specification and as directed by the departmental officers . 38 dadooing walls with colour designed glazed tiles of sizes 300 mm x 200 mm x 6 mm size of approved make and quality and colour set in cement mortor 1 : 2 ( one cement and two sand ) over 10 mm base layer plastering and pointing with white cement neatly as directed . 39 fabrication and supply and delivery of mild steel doors of the following sizes with single leaf outer frame made of 35x35x5 mm equal m.s l angle and shutter frame made of 25x25x5mm equal m.s.l angle for horizontal and vertical members and the shutter frame strengthenened by stiffeners of 2 nos horizontal and 3 nos diagonal using ms flat of size 20x5 mmfully covered with 18 guage plain m.s full sheet welded with shutter frame neatly and also fixing by welding 6 nos of holdfasts made of 35x35x5mm equal m.s.l angle,1 no of wind appliance,2 nos of tower bolts,1 no of aldrop,2 nos of handles,fixing the shutter with 6 nos of 6 inch hinges with outer frame of the door inculding painting the whole unit with one coat of best quality of red oxide primerof size 1.10 x 2.10 m 40 fabrication and supply and delivery of mild steel doors of the following sizes with single leaf outer frame made of 35x35x5 mm equal m.s l angle and shutter frame made of 25x25x5mm equal m.s.l angle for horizontal and vertical members and the shutter frame strengthenened by stiffeners of 2 nos horizontal and 3 nos diagonal using ms flat of size 20x5 mmfully covered with 18 guage plain m.s full sheet welded with shutter frame neatly and also fixing by welding 6 nos of holdfasts made of 35x35x5mm equal m.s.l angle,1 no of wind appliance,2 nos of tower bolts,1 no of aldrop,2 nos of handles,fixing the shutter with 6 nos of 6 inch hinges with outer frame of the door inculding painting the whole unit with one coat of best quality of red oxide primer ofs size 1.00 m x 2.10 m 41 fabrication and supply and delivery of mild steel doors of the following sizes with single leaf outer frame made of 35x35x5 mm equal m.s l angle and shutter frame made of 25x25x5mm equal m.s.l angle for horizontal and vertical members and the shutter frame strengthenened by stiffeners of 2 nos horizontal and 3 nos diagonal using ms flat of size 20x5 mmfully covered with 18 guage plain m.s full sheet welded with shutter frame neatly and also fixing by welding 6 nos of holdfasts made of 35x35x5mm equal m.s.l angle,1 no of wind appliance,2 nos of tower bolts,1 no of aldrop,2 nos of handles,fixing the shutter with 6 nos of 6 inch hinges with outer frame of the door inculding painting the whole unit with one coat of best quality of red oxide primer ofs size 0.75 m x 2.10 m 42 fabrication and supply and delivery of mild steel window of the following sizes with double leaf outer frame made of 35x35x5 mm equal m.s l angle mullion section made of 25x25x5mm equal t section ,shutter frame made of 25x25x5mm equal m.s.l angle for horizontal and vertical members and the shutter frame strengthenened by stiffeners of 2 nos horizontalfor each each shutter using 25x25x5mm equal m.s t section fully covered with 18 gauge plain m.s full sheet welded with shutter frame neatly andalso fixing by welding protective grill with 12mm square m.s rods at an interval of not greater of not greater than 10cm centre to centre to the outer frame , 6nos of hold fasts made of35x35x5 mm equal m.s.l angle,3nos of peg stays with holes for keeping the window open in different positions , 3nos of locking handles ,fixing the shutter with 6 nos of 4inch hinges with outer frame of the windowinculding painting the whole unit with one coat of best quality of red oxide primer of size 1.20 x 1.30 m 43 fabrication and supplyof ntype mild steel glazed ventilators (in two parts) of the following size with outer frame made of 25x25x5 mm equal m.s.l angle with intermediate rails using25x25x5 mm m.s t section for panels with 3mm thick pin headed glass with teak wood beading and glass putty and also fixing by weldingprotective grill with 12mm square m.s rods at an interval of not greater than 10cm centre to centre to the outer frame ,4 nos of hold fasts connecting the 2 parts at 75 mm clear and with 45 degree inclination with25x25x5mm 10g weld mesh and wire mesh including painting the whole unit with one coat of best quality of redoxide primer of .size 0.90x 0.45 m 44 supply of rcc jolly of size 0.90 m x 0.45 m etc complete 45 supply and fixing of rcc jolly of size 0.60 m x 1.30 m including cost and labour charges etc complete 46 fixing charges for steel door in position etc complete 47 fixing charges for steel window in position etc complete 48 fixing charges for jolly in position etc complete 49 providing gronolothickfloor finishin plain cement concrete 1 : 2 : 4 (one cement, two sand and four aggregate ) using 10 to 12 mm gauge hard broken stone jelly including laying , finishing and the top rubbed smooth with trawel thread lining ,curing etc , complete complying with standard specification and as directed by the deparmental officers . 50 distempering two coat with priming coat and two coat with oil bound distemper over cement plastered surface, ceiling and other new surface including cleaning preparing the surface etc, complete. 51 painting two coat approved exterior emulsion over the plastered surface including cost and all other charges etc., 52 painting two coats of new iron works such as steel doors, windows,ventilators, window bars, balustrades etc., with best approved first quality of synthetic enamel paint of approved colour over the existing priming coats, etc., complete complying with standard specifications and as directed by the departmental officers. 53 providing and fixing pvc. rainwater downfall pipes of size 110 mm diametre with necessary shoes,bends and other specials, clamps,screws,nailsteakwood plugs etc complete including cost of all materials. the rate include cost of removable cast iron gratings of appropriate size.the size of teak wood plugs to be used is 150 mm x 25 mm in front and 200 mm x 75 mm in rear and all other sides with a depth of 100 mm . the pipe is to be fixed by means of u clamps at the centre of the pipe to be fixed in addition to these for more than three metres pipie length , complete complying with standard specification 54 suppling and fixing in position of baby freindlyindian water closet , white glazed earthen ware of approved quality with p trap or s trap confirming to is:2556 part xii with sand cushion and forming the closet using 40mm broken jelly lime concreteetc complete 55 supplying and fixing in position of coloured glazed europeyenwater closet of best quality and approved make with 100 mm p or s trap connecting with ci 100 mm dia / pvc pipe of 110 mm dia , double flapped rigid pvc back seat and seat cover with cp brass hinges including cost of white cement , cement for packing , spun yarn , teak wood plugs, brass screws ,etc ,including supplying and fixing 10 litres capacity pvc / 12.5 litres capacity porcelin low level flushing tank with a pair of ci brackets , etc., complete with all fittings such as 15 mm brass ball valve with polythene . 56 manufacturing, supplying and fixing of stainless steel hand rails for staircase steel hand rail for steps ,ramp using 50 mm dia 304 l grade stainless steel pipe of 1.60 mm thick will be provided with tubular supports made of 304 l grade stainless pipe of 25 mm dia of 1.60 mm thick welded to the railing . the supports will be grouted into the wall and provided with 93.00 mm thick stainless steel circular base plate of 304 l grade .the rate shall included for groutting into concrete with necessasry supporting arrangements the hand rail in floor polishing buffing , bonding ,cutting , grinding, conveyance, welding charges, electrical charges etc , complete 57 provision of pvc tank 500 litres 58 wiring with 2 x 1.50 sqm ( 22/0.3) pvc insulated sc unsheathedcu conductor of 1100 v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accesseries,in flush with wall , with tw box 150 mm x 100 mm x 113 mm tw switch box with 3 mm thick hylem sheet coverfor 5a3 pin non inter locking cs plug with painting of suitable colour with contionues earth wire connection of 14 swg tc wire and making good of the concealed portion with suitable colour for concealed plug point sd no 38 for pvc plug point 59 supply and fixing of fancy glass shade and11 wled in the existing light point (sd no 80) 60 supply and fixing of 32 a dpic switch of 500 v with f & n ( side handle ) on suitable t w box with pwd earthing ( s d n o 143 ) 61 supply and run of 2 of 6 sqmm ( 84 / 0.3 ) pvc insulated single core unsheathed copper conductor of 1100 v grade on 7 / 20 g i bearer wire for service connection mains ( s dno 66 ) 62 supply and fuixing of water tight bulk head fitting with guard suitable for 11 w cfl lamp with cfl sd no 83 63 supply and fixing of 1200 mm ( 48 ) a c ceiling fan complete with stepped eloctronic 300 w regulator with 1.00 meter down rod on the existing clamp s d n o 106 64 supplying and fixing of meter board for fixing 32a single phase sc (sd no 125) 65 provision for light 66 fixingofname board includingcost, painting, lettering, installation etc. 67 painting cartoons in hall and toilet and outer ,lettering,drawing pictures 68 construction of drainage @salai colony in brammadesam 69 earth work excavation in hard stiff gravely soilfor narrow foundationwith initial lead and liftas per ss 20 b,etc complete 70 p.c.c.1:4:8 mix using 40mm i.s.s. size hbg metal from approved quarry to work site including cost and conveyance of all materials and labour charges etc. 71 supplying and erecting centering shuttering including necessary supports for plane surface etc,. complete 72 p.c.c.1:2:4 mix using 20mm i.s.s. size hbg metal from approved quarry to work site including cost and conveyance of all materials and labour charges etc. 73 plastering with cement mortar 1:5 mixto 20 mm thick including cost and conveyance of all materials to site and all labour charges etc completefor10 sqm 74 provision for vertical filter (sub estimate) 75 fixingofname board includingcost, painting, lettering, installation etc. 76 gst amount for providing service to government contract works for the above construction works. { gst amount is the total gst amount for total overall quoted amount above this row in column bb for all works in this package} ...

municipality - Tamil Nadu

33223641 additional facility to vadasery christopher busstand sl. no. item description 1 additional facility to vadasery christopher busstand 2 dismantling the plain cement concretecleaning away and carefully stocking materials usefull for reuse 3 dismantling the rein forced cement concrete cleaning away and carefully stocking materials usefull for reuse 4 dismantling the brick masonryincementmortorcleaning away at carefully stocking materials usefull for reuse for any thickness at well 5 removing exisiting door and windows including reused and frame, hinges etc 6 removing the damaged asbestos cement sheet without roof timbers 7 refilling the basement with excavated earth in layers of not more than 15 cm thick well rammed watered and consolidated etc. complete with standard specification. 8 earth work excavation for foundation in all types of soils and sub soils to full depth (such as soils in rock / silt / light black cotton soil / ordinary soil ) except in rock requiring blasting but inclusive of shoring, shuttering and bailing out water wherever necessary and refilling the sides of foundation with excavated earth other than sand in layers of 150 mm thick well rammed and consolidated, depositing the surplus earth in places shown by the departmental officers with initial lead of 10 m and initial lift of 2 m. complete as per tnss23 & 24, v, vi (s2), vii, 9,10a )coloumn depth of 3m 5m 9 boring, providing and installing bored castin situ reinforcement cement concrete pile of specified diameter and length below the pile cap in cement concrete 1:1.5:3 (1 cement, 1.5 coarse sand, & 3 graded stone aggregate of 20 nominal size) to carry a safe working load not less than specified excluding the cost of steel reinforcement but including bentonite solution mechinery & labour charges etc, all complete. (length of pile for payment shall be measured from bottom of pile to the bottom of pile cap). length of payment shall be measured from bottom pile to the bottom of pile cap 10 supply delivery and filling of river sand in layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per standard specification tnss no. 24 & 25. 11 cement concrete of mix 1 : 4 : 8 (one cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. 12 supplying anderrectingsteel centering including necessary supportsfor plain surfaces for reinforced cement concrete works such as coloumn footing,coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floorscomplying with standard specification( tnss no or nbc no 30(s) 86 86 a v, vi(s3)vii .a)column mat, grade beam & drainage 13 supplying anderrectingsteel centering including necessary supportsfor plain surfaces for reinforced cement concrete works such as coloumn footing,coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floorscomplying with standard specification( tnss no or nbc no 30(s) 86 86 a v, vi(s3)vii. b)coloumn 14 supplying anderrectingsteel centering including necessary supportsfor plain surfaces for reinforced cement concrete works such as coloumn footing,coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floorscomplying with standard specification( tnss no or nbc no 30(s) 86 86 a v, vi(s3)vii. c) circular coloumn 15 supplying anderrectingsteel centering including necessary supportsfor plain surfaces for reinforced cement concrete works such as coloumn footing,coloumn pedestals,plith beams, grade beams,staircase steps,etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floorscomplying with standard specification( tnss no or nbc no 30(s) 86 86 a v, vi(s3)vii. d) slab & beam 16 providing and laying in position standardised concrete mix m 20 grade in accordance with is 456 2000 using 20mm and down graded hard broken granite stone jelly for all rcc items of works with minimum cement contenet of 325kg/ cum and maximum water cement ratio of 0.55 including admixture (plasticiser / super plasticiser) in recommended proportions as per is 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the rcc floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requiremnents of is staandards. (no separate payment will be made by the department for the excess usage of materials) a) upto basement 17 providing and laying in position standardised concrete mix m 20 grade in accordance with is 456 2000 using 20mm and down graded hard broken granite stone jelly for all rcc items of works with minimum cement contenet of 325kg/ cum and maximum water cement ratio of 0.55 including admixture (plasticiser / super plasticiser) in recommended proportions as per is 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the rcc floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requiremnents of is staandards. (no separate payment will be made by the department for the excess usage of materials) b) ground floor 18 providing and laying in position standardised concrete mix m 20 grade in accordance with is 456 2000 using 20mm and down graded hard broken granite stone jelly for all rcc items of works with minimum cement contenet of 325kg/ cum and maximum water cement ratio of 0.55 including admixture (plasticiser / super plasticiser) in recommended proportions as per is 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the rcc floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requiremnents of is staandards. (no separate payment will be made by the department for the excess usage of materials) c) first floor 19 supplying and fabrication of steel and placing in position ms / ribbed tor steel grills for rcc works as per design given including cost of steel and gi binding wire in floors etc., complete complying with standard specification in force per kilogram. 20 brick work in cm 1:5 (one cement & five sand) using iii class ground moulded bricks of size 8 3/4x4 1/4 x 2 3/4 including finishing, curing, etc., complete complying with standard specification 100cft upto basement 21 brick work in cm 1:5 (one cement & five sand) using iii class ground moulded bricks of size 8 3/4x4 1/4 x 2 3/4 including finishing, curing, etc., complete complying with standard specification 100cft upto ground floor 22 brick work in cm 1:5 (one cement & five sand) using iii class ground moulded bricks of size 8 3/4x4 1/4 x 2 3/4 including finishing, curing, etc., complete complying with standard specification 100cft upto first floor 23 brick partition walls using iii class ground moulded chamber bricks of size8 3/4x4 1/4 x 2 3/4 in c.m 1:3using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification 10 sqm 24 specialplasteringinc.m. 1 : 3 ( one cement, three sand) to10 mmthickincludingallcostandconveyance ofallmaterialstositeincludingcostofcementwhichwillbepurcharedlocallybythe contractor andconveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. 25 plasteringinc.m. 1 : 4 (1cement 4sand)to12 mmthickincludingallcostandconveyanceofallmaterials tositeincludingcostofcementwhichwillbepurcharedlocallybythecontractor and conveyanceofthesametotheactualworksiteandcostformworkincludingwatering curingandallleadsofgoodpotablewaterandallother. 26 cement concrete of mix 1 : 2 : 4 (one cement two sand four aggregates) using 20mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. 27 weatheringcoarsewith concrete broken brick jelly concrete on 20mm. gauge in pure slaked shell lime (no sand to be used) over roof slab be proportion of brick jelly to being 32cft 12.5 cft. well beaten with wooden beaters giving the required shape and thickness as directed by the departmental officers. 28 finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in cement mortar 1:3 (one cement add three sand) 12 mm thick mixed with water proofing compound conforming to iss at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 29 supply and fixing of m.s grills for windows,with one coat of red oxideprimer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. including phosphating as per isi with rust preventive primer & ready to assemble condition for easy installation at site including dismantlingmaking necessary with power drill to the accessories such as supplying and fixing holdfasts, plastic bush inserts receiver runner bottom shock absorbers etc. and steel doorcomplete as directed by the departmental officer. 30 supplying and erecting pull and push type rolling shutter with i.s.i. make of approved size and section using 18 gauge g.i.sheet with manually operated type. the shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc, complete as per standard specification. 31 supplying and laying of stainlesssteel hand rails fabricated with 50mm dia 40mm dia and 20mm dia stailess steel pipe used in ramp sideof hand rails and four of stainless steel pipe are welded harijontally at the middile of the hand rails made 18mm s.s. pipe & elegant stainless steel balls are provided in required places of hand rail as directed by the departmental officers. the size including cost of material welding with stainless steel grinding and good polishingand fixed in the hand rails with good position as directed by the departmental officers 32 plain cement concrete 1:8:16 (one cement eight fine aggregates and sixteen coarse aggregates) using 20mm size iss hbg metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 33 dadooing sides of walls with glazed design tiles of size 305 x 200 x 6mm set in cement mortar 1:3 ( one cement, three sand) 20mm thick and pointed with the same colour cement including cost and conveyance of all materials, labour charges complete as per standard specification. 34 floor finishing first quality design ceramic tiles of all colours of sizes 305mm x 305mm x 6mm. laid in cm 1:3 mix 10mm thick and pointing with white cement using 0.4kg/sqm including finishing the joint and pointing flush with tiles surface etc complete 35 supply and fixing of granite slabs (super fine polished with machine cut edges) of sizes4x2 and above 18mm to 20mm thick. laid over a base layer of cement mortar 1:3mix 20mm thick and pointed with white cement and pigment of suit the colour of stones and polished neatly as directed by departmental officers. 36 plain cement concrete of mix 1 : 3 : 6(one part of cement threepart of sand six part of aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. tndss no: 28 v, vi (s2) v,vi (s5a) vii 37 supplying and laying in flooringwith fully polished sinthetic grey colour granite stone of 20mm thick (average) of 4 x 2 in size laid over base layer of cementmortar 1:3 (one cement and three sand) 20 mm thick and applying cement slurry &pointed with white cement and colour pigments to the colour of stones and polished neatly as directed by the deparmental officers 38 supplying and painting thewalls with twocoatsweather sealedexterior emulsion paint as instructed by the departmrntal officers includingpreparation of surface curing, etc complete in all floorscomplying with standard specification. ( the colour and shade of the paint shall be got approved by the departmental officers.) 39 painting the new iron works such as steel doors, windows,ventilators windows bars,balustrades etc,in all floor withtwo coats of best approved first quality and colour of synthetic enamel paint of approved quality, colour and brand (to be approved by executive engineer before use on works ) over one the existing red oxide priming coat in all floors excluding cost of priming coat etc,complete complying with standard specification. ( the make, quality and colour of paint should be got approved bythe engineer in charge before use on works )( tnss no or nbc no 61 v vi (54) 3) 40 supply and fixing of pvc soliddoors with necessay accessories and locking arrangements including cost and conveyance of all materials and labour charges etc., complete as per standard specification 41 supplyingand fixing of rcc precast slab withcementconcrete 1:2 : 4mix using 20 mm metal for 200mm thick includingall costandconveyance of all materials and all labour and materials chargesetc complete as per standard specification 42 supplying and fixing in position best quality and approved make indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass cp pillar tap, 32mm dia b class gi waste pipe with rubber plug and chain, 15mm dia gm wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia cp brass waste coupling including fixing of wash basin using ci brackets on to the wall in position with tw plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (the wash hand basin and specials should be got approved by the executive engineer before use on works). 43 supplying and fixing in position white glazed indian water closet of size 580 x 440mm of orissa type of approved quality with p or s trap with sand cushion and forming flooring alround the closet using 40mm broken brick jellylime concrete 1:2:5 ; 100mm thick and finishing the top torequired slope and including giving necessary connection to cast iron soil pipes by dismandling masonry / rcc works and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmentalofficers. (the water closet should be got approved by the executive engineer before use on works.) 44 supplying and fixing in position urinal of approved quality andmake with p os s trap with double flapped rigid p.v.c. seat cover with c.p. brass hinges,12.5 litres pvclow level flushing tank with all internal fittings etc., complete complying with standard spoecifications 45 supplying and fixing in position white glazed european water closet of approved quality andmake with p os s trap with double flapped rigid p.v.c. seat cover with c.p. brass hinges,12.5 litres pvclow level flushing tank with all internal fittings etc., complete complying with standard spoecifications 46 supply and laying of 2 x 10 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. 47 supply and laying of 4 x 16 sq.mm pvc armoured ltug cable in a trench to the excavated at a depth of 0.75 metre putting 0.15 mt. layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. 48 supply and fixing of brass cable gland for 4 x 16 sq.mm pvc armoured ltug cable, with earth connection. 49 supply and laying of 31/2 x 25 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 metre putting 0.15mt. layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. 50 supply and fixing of brass cable gland for 31/2 x 25 sq.mm ltug armored cable with earth connection. 51 supply and run of 25mm x 3mm tinned copper flat necessary clamps / supports on wall / floor / ground floor earth connection. 52 earthing as per the isi specification with an earth electrode of 2.1mt class b gi pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm rcc cover slab for the brick masonry. 53 wiring with 2 x 1.5 sqmm (22 /0.3 ) pvc insulated single core unsheathed copper conductor cable of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories inflush with wall with 3mm thick hylum sheet cover with tw switch box and 5a f.t. switch with continuous earth wire connection of 14 swg tc wire for making good of the concealed portion with suitable colour for pvc concealed light point / fan point (for electronic regulator). etc, complete as per standard specifications. 54 wiring with 2 x 1.5 sqmm (22 /0.3 ) pvc insulated single core unsheathed copper conductor cable of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories inflush with wall with 150 x 100 x 113 mm tw switch box with 3mm hylum sheet cover for5a 3 pin non inter locking cs plug with continuous earth wire connection of 14 swg tc wire and making good of the concealed portion with suitable colour for concealed pvc plug point.etc, complete as per standard specifications 55 wiring with 2 x 4 sqmm (56 / 0.3mm ) pvc insulated single core unsheathed copper conductor cable of 1100v grade in suitable heavy gauge pvc pipe on wall and ceiling with pvc accessories inflush with wall with 150mm x100mm x75mm ms switch box concealed type with 3mm thick hylum sheet cover for 15a 3pin flush type non inter locking cs plug with continuous earthwire connection of 14 swg tc wire and making good of the concealed portion with suitable colour for concealed power plug point.etc, complete as per standard specifications. 56 supply andfixing of 16 amps dp switch with metal glad of 500v with fuse and nuetral ( side handle) on suitable tw box pwd earthing 57 supply andfixing of 16 ampsfuse unit and neutral ( side handle) on suitable tw box pwd earthing 58 supply and fixing of tneb meter board suitable for 32a single phase service connection with 32a fuse unit (500v) 32a neutral link and earth link (1 x 1/8 copper flat) on tw plank of size 375mm x 300mm x 19mm with supporting tw reepers of 1 thick an either side with painting with suitable bolt and nuts for fixing the tw plank on wall with earth connection and inter connection with 7/20 pvc insulated copper wire from eb meter to fuse unit 59 supplying laying and jointing pvc pipes of approved quality and best varity of b class pipe of the following sizes including fixing g.i specials but excludingcost of such specials cutting threading of pipes andfixing to wall with necessary teak wood plugs, clamps and screws masking holes on the wall or drilling holesin roof and making good the dismandled portions to original conditions with necessary brick work and concrete and plastering where ever necessary with necessary scafolding charges. the pipes are to be painted with two coats of good variety and best approved quality of synthetic enamel paint over a priming coat of red oxide primer etc., complete.a)110mm dia pvc pipe 4 kg/cm2 60 supplying laying and jointing pvc pipes of approved quality and best varity of b class pipe of the following sizes including fixing g.i specials but excludingcost of such specials cutting threading of pipes andfixing to wall with necessary teak wood plugs, clamps and screws masking holes on the wall or drilling holesin roof and making good the dismandled portions to original conditions with necessary brick work and concrete and plastering where ever necessary with necessary scafolding charges. the pipes are to be painted with two coats of good variety and best approved quality of synthetic enamel paint over a priming coat of red oxide primer etc., complete.b)75mm dia pvc pipe 4 kg/cm2 61 supplying laying and jointing pvc pipes of approved quality and best varity of b class pipe of the following sizes including fixing g.i specials but excludingcost of such specials cutting threading of pipes andfixing to wall with necessary teak wood plugs, clamps and screws masking holes on the wall or drilling holesin roof and making good the dismandled portions to original conditions with necessary brick work and concrete and plastering where ever necessary with necessary scafolding charges. the pipes are to be painted with two coats of good variety and best approved quality of synthetic enamel paint over a priming coat of red oxide primer etc., complete.c)32mm dia pvc pipe 10 kg/cm2 62 supplying laying and jointing pvc pipes of approved quality and best varity of b class pipe of the following sizes including fixing g.i specials but excludingcost of such specials cutting threading of pipes andfixing to wall with necessary teak wood plugs, clamps and screws masking holes on the wall or drilling holesin roof and making good the dismandled portions to original conditions with necessary brick work and concrete and plastering where ever necessary with necessary scafolding charges. the pipes are to be painted with two coats of good variety and best approved quality of synthetic enamel paint over a priming coat of red oxide primer etc., complete.c)25mm dia pvc pipe 10 kg/cm2 63 supplyingandfixingin position best approvedof bis quality 110mm p.v.c rainwaterdownfallpipe having a pressure of 4kg / sq.cm including cost of necessary pvc shoe,pvc bend, cast iron gratings of required diameter and special clamps, brass screws, nails etc, and fixing of cast iron gratings at junction of parapet and the rcc roof slab including finishing neatly etc, complete. the rate shall be inclusive of cast of removable cast iron grating. the pvc pipe shall be fixed in wall with special type of uclamp at the centre of the pipe line in addition to those for more than 3.00mt pipe length etc,completecomplyingwithstandardspecifications. 64 supplying and fixing in position first quality and approved variety of 32mm gun metal gate valve (heavy type) with i.s.i.mark of the following sizes including cost of shellac , thread etc,.including labour for cutting and threading of g.i.pipes etc.,complete complying with standard specifications for both internal and external water supply arrangements. 65 supplying and fixing in position p.v.c. specials such as plain bend, door bend, plain tee, door tee, offsets,y junction, plain or with door of various sizes best quality confirming to i.s.s and providing leakproof joints including fixing to wall and giving connection to the p.v.c, soil stacks, dismadling the brick masonry or r.c.c.floor or roof slab and redoing the dismandled portion to original condition etc., complete complying with standard specifications.a)110mm dai pvc elbow(mould) 66 supplying and delivery of following pvc pipe and specials with isi mark including cost and convience of materials etc completed.. a)75mm dia pvc elbow 4kg 67 75mm dia door elbow 68 75mm dia 45 pvc elbow 69 110mm dia pvc door elbow 70 110mm dia pvc 45 elbow 71 32mm dia pvc elbow 72 25mm dia pvc elbow 73 32mm dia pvc tee 74 25mm dia pvc tee 75 32mmx25mm dia pvc tee 76 25mmx20mm dia pvc tee 77 32 x 25mm pvc reducer 78 supplying and fixing of 2000 liters capacity hdpe tank with is specification is 10701/96 the tank is meant for outdoor (or)indoor use complete with removable hinged top locking arrangement and to make provision to fix water supply pipe lines, necessary man hole with cover and including all pvc specials pugs, screws nails to fix the tank etc., complete and the tank should fixedfirming as directed by the departmental officers.the rate shall be inclusive of all materials, labour conveyance hoisting and fixing charges etc. (the water tank should be got approved by the eebefore use on work. 79 supply and fixing of ci nahini / floor trap with stainless steel gratings 100 mm x 75 mm including all charges etc, complete as per standard specification. ...

Chennai Petroleum Corporation Limited - Tamil Nadu

33207938 zonal contract 2022 23 for projects related electrical works in manali refinery of cpcl zonal contract 2022 23 for projects related electrical works in manali refinery of cpcl , ht cable laying in trenches: the scope of work includeslaying of armoured / unarmoured pilca / pvc insulated and pvc sheathed / xlpe ht power cables of voltage grade exceeding 1.1 kv but not exceeding 11 kv ( e ) of following sizes in pre excavated cable trench or existing trench / rcc or hume or stoneware or metal pipe / masonry duct, fixing of cable number tag at specified interval and both ends, testing plus transportation from stores to site , unpacking, straightening, dressing of cable, required clamping, cable route markering at a frequent interval and returning the empty drum / cable drum with unused cable, if any, to stores / scrap yard or any other place within cpcl , all complete with labour as per the drawings, specifications of the tender and directions of the engineer in charge. note: necessary crane or forklift, tractor and trailershall be arranged by the contractor. the scope also includes area cleaning and vegetation removal as a enabling activity for cable laying. the scope excludes supply of cables. , single core, upto 630 sq.mm , from 3c x 120 sq.mm to 3c x 185 sq.mm , from 3c x 185 sq.mm to 3c x 300 sq.mm , ht cable laying on trays / structures: the scope of work includes horizontal and vertical laying of armoured / unarmoured pilca / pvc insulated and pvc sheathed / xlpe ht power cables of voltage grade exceeding 1.1 kv but not exceeding 11 kv ( e ) of following sizes on cable racks / wall and steel structures upto any height, fixing of saddles, aluminium strip, number tags ( if required ) , testing plus transportation from stores to site, unpacking, straightening, dressing of cable, fixing with clams / cleats as required and returning the empty drum / cable drum with unused cable, if any, to stores / scrap yard or any other place within cpcl , all complete with labour as per the drawings, specifications of the tender and directions of the engineer in charge. note: necessary crane or forklift, tractor and trailershall be arranged by the contractor.the scope also includes area cleaning and vegetation removal as a enabling activity for cable laying. the scope excludes supply of cables. , single core, upto 630 sq.mm , from 3c x 120 sq.mm to 3c x 185 sq.mm , from 3c x 185 sq.mm to 3c x 300 sq.mm , laying of lt power / control / telephone / plant communication and other cables in trenches: the scope of work includes horizontal and vertical laying of one or more armoured / unarmoured pijf / pvc insulated and pvc sheathed / xlpe lt power ( voltage grade upto1.1 kv ) / multi pair or multicore control cables / telephone and other cables of following sizes in pre excavated cable trench or existing trench / rcc or hume or stoneware or metal pipe / masonry duct, fixing of cable number tag at specified interval and both ends, testing plus transportation from stores to site, unpacking, straightening, dressing of cable, required clamping, and returning the empty drum / cable drum with unused cable, if any, to stores / scrap yard or any other place within cpcl , all complete with labour as per the drawings, specifications of this tender and directions of the engineer in charge. for 2c, 3c, 4c cables below rates of 3.5c cables will be applicable. note: necessary crane or forklift, tractor and trailershall be arranged by the contractor. the scope also includes area cleaning and vegetation removal as a enabling activity for cable laying. the scope excludes supply of cables. , all controlcables and power cables upto 3.5 c x 25 sq.mm , power cables above 3.5c x 25 sq.mm upto 3.5c x 95 sq.mm , power cables above 3.5c x 95 sq.mm upto 3.5c x 185 sq.mm , power cables above 3.5c x 185 sq.mm upto 3.5c x 300 sq.mm , single core cable above 500 sq.mm upto 1000 sq.mm , laying of lt power / control / telephone / plant communication and other cables on cable trays / structures: the scope of work includes horizontal and vertical laying of one or more armoured / unarmoured pijf / pvc insulated and pvc sheathed / xlpe lt power ( voltage grade upto1.1 kv ) / control / telephone and other cables of following sizeson cable racks / wall and steel structures upto any height, fixing of saddles, aluminium strip, fixing of cable number tag at specified interval and both ends, testing plus transportation from stores to site, unpacking, straightening, dressing of cable, fixing with clams / cleats as required and returning the empty drum / cable drumwith unused cable, if any, to stores / scrap yard or any other place within cpcl etc. all complete with labour as per the drawings, specifications of this tender and directions of the engineer in charge. for 2c, 3c, 4c cables below rates of 3.5c cables will be applicable. note: necessary crane or forklift, tractor and trailershall be arranged by the contractor. the scope also includes area cleaning and vegetation removal as a enabling activity for cable laying. the scope excludes supply of cables. , all controlcables and power cables upto 3.5 c x 25 sq.mm , power cables above 3.5c x 25 sq.mm upto 3.5c x 95 sq.mm , power cables above 3.5c x 95 sq.mm upto 3.5c x 185 sq.mm , power cables above 3.5c x 185 sq.mm upto 3.5c x 300 sq.mm , single core cable upto 1000 sq.mm , temporary cable laying : the scope of work includes temporary layingof ht / lt power / control / telephone cables on any surface as required including shifting, handling, testing, cutting, sealing, etc., transporation of cable from stores to site and returning the empty drum / cable drum with unused cable, if any, to stores / scrap yard or any other place within cpcl , all complete with labour and materials as per the drawing, specification of this tender and direction of the engineer in charge.for 2c, 3c, 4c cables below rates of 3.5c cables will be applicable. note: necessary crane or forklift, tractor and trailershall be arranged by the contractor. the scope also includes area cleaning and vegetation removal as a enabling activity for cable laying. the scope excludes supply of cables. , all lv control cables and lv power cables upto 3.5c x25 sq.mm , lv power cables above 3.5c x 25 sq.mm upto 3.5c x 95 sq.mm , lv power cables above 3.5c x 95 sq.mm upto 3.5c x 185 sq.mm , lv power cables above 3.5c x 185 sq.mm upto 3.5c x 300 sq.mm , single core lv power cable upto 1000 sq.mm , single core ht cable upto 630 sq.mm , ht cables from 3c x 120 sq.mm upto 3c x 185 sq.mm , ht cables from 3c x 240 sq.mm upto 3c x 300 sq.mm , cat 6 cabling: the scope of work includes supply and laying of cat 6 type in already available pvc pipe / casing caping with all necessary accessories for computer networking. only isi marked wires of make finolex / polycab / havells / kei / rpg / v guard shall be used. , straight through jointing kit , ht cable jointing kits: the scope of work includes supply of heat shrinkable straight through jointing kitsand making straight through joints for xlpe insulated ht power cables 6.6kv / 11kv ( ue ) grade of following sizeswith copper / aluminium ferrules including all labour, tools and materials, as per the direction of engineer in charge. , 1c upto 630 sqmm , 3c upto 300 sqmm , lt cable jointing kits: the scope of work includes supply ofstraight through jointing kitsand making straight through joints for pvc insulated ltpower cables, control cables of 1100v grade of following sizeswith copper / aluminium ferrules including all labour, tools and materials, as per the direction of engineer in charge. for 2c, 3c, 4c cables below rates of 3.5c cables will be applicable. , all control cables / lv power cables upto 3.5c x 25 sq.mm , lv power cables above 3.5c x 25 sq.mm upto 3.5c x 95 sq.mm , lv power cables above 3.5c x 95 sq.mm upto 3.5c x 185 sq.mm , lv power cables above 3.5c x 185 sq.mm upto 3.5c x 300 sq.mm , single core lv power cable upto 1000 sq.mm , glanding & end termination , ht end termination kits: the scope of work includes supply of heat shrinkable end termination kits and making end terminations for xlpe / pvc insulated ht power cables of 6.6kv / 11kv ( ue ) grade of following sizes including supply of copper / aluminium lugs, crimping / soldering as necessary, earthing of armour, connecting to equipment terminal, including cutting, stripping and glandingwith all labour, tools and materials and as per the direction of engineer in charge. note: the scope excludes supply of glands. , 1c upto 630 sq.mm , 3c upto 300 sqmm , lt cable end termination: the scope of work includes glanding and making end terminations for xlpe / pvc insulated lt power cables of 1100 v grade of following sizes including supply of copper / aluminium lugs, bimetallic strip, crimping paste, crimping / soldering as necessary, earthing of armour, connecting to equipment terminal, including cutting stripping and glandingwith all labour, tools and materials and as per the direction of engineer in charge. for 2c, 3c, 4c cables below rates will be applicable. note: the scope excludes supply of glands. , all lv control cables and lv power cables upto 3.5c x 25 sq.mm , lv power cables above 3.5c x 25 sq.mm upto 3.5c x 95 sq.mm , lv power cables above 3.5c x 95 sq.mm upto 3.5c x 185 sq.mm , lv power cables above 3.5c x 185 sq.mm upto 3.5c x 300 sq.mm , single core lv power cable upto 1000 sq.mm , communication cable end termination: the scope of work includes end terminations oftelephone / plant communicationcables of 1100 v gradeof following sizes including supply oflugs, crimping / soldering as necessary, connections in crone terminal / any terminals, including cutting , stripping and glanding, all complete with labour, tools and material, as per specifications of this tender and directions of engineer in charge. the scope excludes the supply of cable glands. , 100 paircommunication cable , 20 pair to 50 pair communication cable , upto 10 pair communication cable , gi pipes: the scope of work includes supply and laying of gi pipes of following sizes of class ‘b’ type, fixed on steel, duct bank, concrete, wall crossing, wing trenches or similar structures, including shifting of pipes to site using contractors vehicle, cutting, bending, threading, supply & installation of supports, clamps, small iron structures, spacer, seats, plugs, bush and fittings / fixtures like bends, tees, nipples, reducers etc., all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. the scope of work also includes sealing of pipe ends and joints with bushes and bitumen based fillings and other miscellaneous works to make the piping water tight. , 150 mm od gi pipe , 100 mm od gi pipe , 50 mm od gi pipe , miscellaneous electrical works , supply of extension board: the scope of work includes supply of 4 way extension board ofhavells ahlklup104 maglev or equivalent model, as per the specifications of this tender and directions of engineer in charge. , decorative luminaire: the scope of work includes supply and fixing of ( 2’ x 2’ ) decorative led luminaire of philips make rc380b g3, minimum 34w, 6500k fiting or equivalent in philips / cg / ge / havells, including consumables required for suspension / clamp arrangement, civil work ( if any ) required for installation, all complete with labour , tools and materials, as per the specifications of this tender and directions of engineer in charge. , led downlights: the scope of work includes supply & fixing of recess mounted, compact vertical, round shapedupto 10w led 6000k downlighter with removable driver of havells make or equivalentsuitable for low ceiling heights, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. , tube light fitting: the scope of work includes supply and fixing of led decorative slim linear 4 ft batten fittings with bulb min.18 w 6500 k1, cool daylight ( cdl ) , of havells catalogue or equivalent , including civil work ( if any ) required for installation, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. , twin led tube light fitting: the scope of work includes supply and fixing ofmin. 2 x 18 watts 4 ft industrial tube light fittings with bulb of havells catalogue titania sleek t8 led tubelight or equivalent, including civil work ( if any ) required for installation, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. , socket outlet: the scope of work includes supply and fixing of 20 amps, 240 volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps, g series, single pole mcb in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, including connections, testing and commissioning etc. as required, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. note:isi marked sockets of approved make shall be used. , 3 phase 6 way distribution board: the scope of work includes supply, erection, connecting, testing and commissioning of 3 phase 6 way distribution board concealed in wall / partition. the board shall be powder coated with below mentioned provisions and necessary accessories for db, all complete with labour , tools and materials, as per the specifications of this tender and directions of engineer in charge. note:isi marked components of approved make shall be used. , with incoming 63a four pole mcb, 63a 30ma elcb and out going 18 nos. of 6 / 10 amps mcbs , 4 way flp / wp junction box: the scope of work includes supply of 4 way junction box of below mentioned type, as per the specifications of this tender and directions of engineer in charge. note:isi marked components of approved make shall be used. , flameproof jb , weather proof jb , supply of mcb: the scope of work includes supply of following rating, 240 / 415 volts, 50hz, 10kaminiature circuit breaker ( suitable for motor, lighting and other inductive loads and conforming to is 8828: 1996, iec 60898: 2002 ) of following poles in the existing mcb db with required rails / fastenersfor fixing as per the specifications of this tender and directions of engineer in charge. note: isi marked mcbs as per approved vendor list attached with the tender shall be used. , upto 32a, single pole , upto 32a, double pole , upto 63a, 4p / tpn , installation of mcb:the scope of work includes fixing of mcbupto 63 a, 4p with required rails / fastenersincluding connections, testing and commissioning etc, all complete with labour and tools, as per the specification of this tender and directions of engineer in charge , supply of rccb: the scope of work includes supply offollowing rating 240 / 415 volts, residual current circuit breaker ( rccb ) , isi marked, having a sensitivity current indicated miliamperes in the existing mcb db with required rails / fastenersfor fixing, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. note: isi marked rccb shall be used. , upto 32 a, 30 ma, 2p , 63 amps., 30 ma, 4p , installation of rccb:the scope of work includes fixing of rccb of rating upto 63 a, 4p with required rails / fastenersincluding connections, testing and commissioning etc, all complete with labour and tools, as per the specification of this tender and directions of engineer in charge , supply of mpcb: the scope of work includes supply offollowing rating ofmotor protection circuit breaker ( mpcb ) , isi marked with required rails / fastenersfor fixing, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. , upto 6.3 a , above 6.3 a upto 13 a , above 13 a upto 25 a , above 25 a upto 32 a , installation of mpcb:the scope of work includes fixing of mpcb of following rating with required rails / fastenersincluding connections, testing and commissioning etc, all complete with labour and tools, as per the specification of this tender and directions of engineer in charge. , supply of pvc wires: the scope of work includes supply of following size of pvc insulated, copper conductor for laying in the existing surface / recessed, pvc / steel conduit / pvc casing and capping as required, as per the specifications of this tender and directions of engineer in charge. note: only isi marked cables shall be used. , 1.5 sq.mm , 2.5 sq.mm , 4 sq.mm , 6 sq.mm , supply of pvc conduits: the scope of work includes supply of following size of pvc conduit along with the accessories to be used for installation in surface / concealed as required, as per the specifications of this tender and directions of engineer in charge. note: only isi marked conduits shall be used. , upto 25 mm , above 25 mm upto 40 mm , above 40 mm , laying of pvc conduit: the scope of work includes fixing of following size of pvc conduit along with the accessories to be used for installation in surface / concealed as required, including cutting the wall and making good the same in case of recessed, as per the specifications of this tender and directions of engineer in charge. , upto 40 mm , more than 40 mm , supply of pvc casing / caping: the scope of work includes supply of following size of pvc casing and capingon surface as required, as per the specifications of this tender and directionsof engineer in charge. , 20 mm x 10 mm , 25 mm x 10 mm , 40 mm x 20 mm , laying of pvc casing / caping: the scope of work includes fixing of following size of pvc casing and capingon surface as required, as per the specifications of this tender and directions of engineer in charge. , upto 40 mm x 20 mm , laying of pvc wires: the scope of work includes drawing / laying of following size of pvc insulated, copper conductor for laying in the existing surface / recessed, pvc / steel conduit / pvc casing and capping as required, as per the specifications of this tender and directions of engineer in charge. , 1 x 1.5 sq.mm , 2 x 1.5 sq.mm , 3 x 1.5 sq.mm , 1 x 2.5 sq.mm , 2 x 2.5 sq.mm , 3 x 2.5 sq.mm , 2 x 4 sq.mmto 2 x 6 sq.mm , switch socket / outlet: the scope of work includes supply, fixing and connection of 250 vflush type anchor make or approved equivalent switch, socket bell push etc. on perpex sheet on ms box including supply and fixing of nuts, bolts, cutting etc. but excluding the perpex sheet, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. , 1 way 5 / 6 amps. penta flush type switch with isi mark , 1 way 15 / 20 amps penta flush type switch with isi mark , 5 pins 5 / 6 amps. penta flush type socketwith isi mark , 6 pins 10 / 20 amps.socket outlet with isi mark , 3 pins 5 / 6 amps. isi marked polycarbonate unbreakable plug top , 3 pins 15 / 16 amps. isi marked polycarbonate unbreakable plug top , telephone jack , 10 / 20 amps 5 pins switch socket combinedisi marked , supply and fixing of module box:supply and fixing of plastic / metal boxes of following sizes with all accessories including necesssary base frame plates / mounting plates, etc., suitable for fixing decorative switches of type roma or equivalent make in havells / siemens / anchor / l&t , 1 or 2 module box , 3 module box , 4 module box , 6 module box , 8 module box , 12 module box , supply, fixing and connection of modular type of anchor make ( roma ) or approved equivalent switch, socket bell push etc in havells / siemens / anchor / l&t / equivalent, complete with labour, tools andmaterials as per direction of the engineer in charge. , 10 a, 1way switch , 20a, 1 way switch , 3 pins 5 / 6 amps socket with isi mark , 3 pins 10 / 20a, heavy duty uni socket outlet with isi mark , 3 pins 5 / 6 amps. isi marked polycarbonate unbreakable plug top , 3 pins 15 / 16 amps. isi marked polycarbonate unbreakable plug top , rj11 telephone jack single with shutter along with base module box , single module dimmer / fan regulator 450w , rj 45 computer socket cat 6 with shutter & box , elmex terminals: the scope of work includes supply & installation of elmex type terminals, wherever required. the scope of work also includes drilling holes, providing and fixing clamps / din rail, nuts and bolts etc. suitable for terminating copper conductor of below mentioned size as per drawings and specifications of this tender and directions of engineer in charge. ( per terminal ) . , elmex connectors of 2.5 / 4 sq.mm , elmex connectors of 6 / 10 sq.mm , elmex cbt 110 connectors from 16 sq.mm upto 50 sqmm ( with bars ) , din rail channels: the scope of work includes supply and fixing of din rail channels for installation of elmextype terminals wherever required. the scope of work also includes drilling holes, providing and fixing clamps, nuts and bolts etc., as per the drawings and specifications of this tender and directions of engineer in charge. , telephone system , 2 pair telephone cable: the scope of work includes supply and laying of 2 pair telephone cablefrom the epabx system / telephone jb to officer’s table, all complete with labour, tools and materials, as per the specifications of this tender and directions of engineer in charge. , 100p telephone junction box: the scope of work includes supply and installation of 100 pair telephone junction box with crone connector with cable entry provision for1 number of 100 pair cable for incomingand 1 number of 50 pair cable, 2 numbers of 20 pair cable , 1 number of10 pair cable for out going, all complete with labour, tools and materials, as per the specifications of this tender and directions of engineer in charge. , 50p telephone junction box: the scope of work includes supply and installation of 50 pair telephone junction boxwith crone connector with cable entry provision for 1 number of50 pair cable for incomingand 2 numbers of20 pair cableand 1 number of 10 pair cablefor out going, all complete with labour, tools and materials, as per the specifications of this tender and directions of engineer in charge. , 20p telephone junction box: the scope of work includes supply and installation of 20 pair telephone junction boxwith crone connector with cable entry provision for 1 number of 20 pair cablefor incomingand 2 numbers of 10 pair cablefor out going, all complete with labour, tools and materials, as per the specifications of this tender and directions of engineer in charge. , supply of corded telephone: the scope of work includes supply of telephone instruments of model m71corded landline phone of beetel make or equivalent as per the direction of engineer in charge. , supply of cordless telephone: the scope of work includes supply of telephone instruments of model x69n cordless landline phone of beetel make or equivalent as per the direction of engineer in charge. , supply of flameproof telephone:the scope of work includes supply of flameproof telephone instrument as per the specification of this tender and directions of engineer in charge. , fans , ceiling fan: the scope of work includes supply, installation, testing and commissioning of 1200mm sweep bldc ceiling fan ofbajaj / crompton greaves / khaitan / usha / havells / atomberg / equivalent make of following sweep withceiling fan, including wiring the down rod of standard length ( upto 30 cm ) with 1.5 sqmm, pvc insulated, copper conductor, single core cable etc., as required, , as per the specifications of this tender and directions of engineer in charge. , exhaust fan: the scope of work includes supply offresh air fan / exhaust fan of almonard / bajaj / crompton greaves / khaitan / usha / havells / equivalent make of below mentioned sweep andinstallation in existing frames, testing and commissioning offresh air fan / exhaust fan, including lead in wires and accessories as required, all complete with labour and material, with necessary fixing accessories, louvers wherever required, as per the specifications of this tender and directions of engineer in charge. , 300 mm sweep , 450 mm sweep, heavy duty industrial type , upto 450 mm sweep, flp , wall mounted fan: the scope of work includes supply of bldc wall mounted fans of bajaj / crompton greaves / khaitan / usha / havells / atomberg / equivalent make of 400mm sweep and installation, testing and commissioning of wall mounted fan, including wires and accessories as required, all complete with labour and material, necessary fixing accessories, as per the specifications of this tender and directions of engineer in charge. , pedestal fan: the scope of work includes supply ofbldc pedestal fans of bajaj / crompton greaves / khaitan / usha / havells / equivalent make of 400mm sweep and installation, testing and commissioning of the same, including wires and accessories as required, all complete with labour and material, as per the specifications of this tender and directions of engineer in charge. , installation & commissioning of flp / wp fittings: the scope of work includes installation, connection, testing and commissioning of flp / wp type fittings such as junction boxes, welding sockets, lighting panels, convenience outlets / convenience outlets with built in transformer etc, in surface / channel / wall / steel structuresall complete, with labour and tools as per drawings & specifications of this tender and directions of engineer in charge. , weight of the unit upto 2 kg , weight of the unit above 2 kg but upto 5 kg , weight of the unit above 5 kg but upto 10 kg , weight of the unit above 10 kg but upto 20 kg , weight of the unit above 20 kg but upto 50 kg , cable tray , supply of cable trays: the scope of work includes supply of the following sizes of gi cable trays of ladder type / perforated type made out of hot rolled sheet steel of 2mm thick including straight length elbows, tees, crosses, couplers plates etc., as per the specification of this tender and directions of engineer in charge. , upto 50 mm , above 50 mm but upto 100 mm , above 100mm but upto 150 mm , above 150 mmbut upto 300 mm , above 300 mmbut upto 450 mm , installation of cable trays: the scope of work includes installation of the following sizes of gi cable trays of ladder type made out of hot rolled sheet steel of 2mm thick including straight length elbows, tees, crosses, couplers plates, cable tray supports etc., including welding and bolting of cable trays in existing / new supports, all complete with labour and tools, as per the specification of this tender and direction of engineer in charge. , upto 150 mm , above 150 mmbut upto 300 mm , above 300 mmbut upto 450 mm , push button stations , supply : the scope of work includes supply of industrial weather prooftype push button stations with canopy, with start & stop push buttons and ammeter of scale suitable for motor , as per the specifications of this tender and directions of engineer in charge. , supply: the scope of work includes supply of industrial flp type push button stationswith canopy, with start & stop push buttons and ammeter of scale suitable for motor, as per the specifications of this tender and directions of engineer in charge. , supply: the scope of work includes supply of industrial frp type push button stations with canopy, with start & stop push buttons and ammeter of scale suitable for motor, as per the specifications of this tender and directions of engineer in charge. , supply : the scope of work includes supply of industrial weather prooftype push button stations with canopy, with start & stop push buttons, auto / manual switch and ammeter of scale suitable for motor, , as per the specifications of this tender and directions of engineer in charge. , supply: the scope of work includes supply of industrial flp type push button stationswith canopy, with start & stop push buttons, auto / manual switch and ammeter of scale suitable for motor, as per the specifications of this tender and directions of engineer in charge. , supply: the scope of work includes supply of industrial frp type push button stations with canopy, with start & stop push buttons, auto / manual switch and ammeter of scale suitable for motor, as per the specifications of this tender and directions of engineer in charge. , commissioning: the scope of work includes installation, testing & commissioning of wp / frp / flp push button stations, with ms channels grouted with pcc including excavation, alignment, erection and connection of push button, connection of control cable, earthing including supply and fixing of saddles, nuts, bolts etc., painting with two coats of bituminous aluminium paint / synthetic enamel paint over a coat of red oxide primer, including supply of necessary hardware, touch up painting, including supply of paint, including transportation to site at the place of installation, unpacking, using contractors own testing equipments, tools & tackles, all complete with labour , tools and materials, as per the specifications of this tender and directions of engineer in charge. , earthing system , earth pit: the scope of work includes supply , installation , testing and commissioning ofearth pitwith 65 mm dia 3000 mm longearth electrodes , complete with all necessarymaterialsincludingexcavation of earth pit, all civil works, chamber constructions , fillingwith charcoaland salt, back filling , providing cement ( concrete ) slab for earth pits, paintingand markingof earth pit nosand connectionsincluding all labour, tools and materials as per the specifications of this tender and directions of engineer in charge. , earth flat / wire: the scope of work includes supply, installation and connection of following gi earthing strips along the cable trenches or cable trays or fixing to walls or structures and for connecting equipments to the plant grid including welding at joints, providing anti corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connection etc., including all labour and materials, as per approved drawings, specification of this tender and direction of engineer in charge. , supply of earth flats , 75 x 10 gi earth flat , 25 x 3 gi earth flat , 50 x 10 gi earth flat , 40 x 6 gi earth flat , 25 x 6 gi earth flat , 8 swg wire for earthing , installation of earth flats / gi wire / pvc insulated cable cores the scope of work includes installation ofearth flats / gi wire / pvc insulated single core cablefor earthing with all labour and material including nuts, bolts, washers, aluminium lugs etc , as per the specifications of this tender and directions of engineer in charge. , 75 x 10 gi earth flat , 50 x 10 gi earth flat , 40 x 6 gi earth flat , 25 x 3 gi earth flat , 25 x 6 gi earth flat , 8 swgwire , upto 25 sq.mm cable , above 25 sq.mm upto 70 sq.mm cable , above 70 sq.mm upto 185 sq.mm cable , lighting system , supply of street light poles: the scope of work includes supply of7 m ( above ground ) octagonal gi street light poles of make bajaj / philips / cg / ge / havells / equivalent make with marshalling box to accommodate insulated armoured cablewith terminals, with supply of all necessary accessoriesandmaterial , as per the drawings attached with the tender and direction of engineer in charge. the scope of work also includes supply of suitable cable from fixture to marshalling box but excluding street light fixtures. , installation / commissioning of street light poles: the scope of work includes installation of7 metres street light poles with marshalling box to accommodate 2 nosof4 x 10 sq.mm pvc insulated armoured cablewith elmex connectors, earthing of pole / marshalling box & connecting it to the existing earth grid, but excluding lighting fixtures , including excavation, suitable foundation / mounting arrangement with all labour and tools , as per specifications and drawings attached with the tender and direction engineer in charge. if the street lighting pole is issued as a free issue item to contractor by cpcl, then the contractor is required to shift the lighting pole within the cpcl premesis to the site as per the direction of engineer in charge. the scope of work also includes laying of suitable cable from fixture to marshalling box. , supply of platform light poles: the scope of work includes supply of3 metres gi platform light poleswith supply of all necessary accessories and material, as per the drawings attached with the tender and direction of engineer in charge. the scope of work also includes supply of suitable cable from fixture to marshalling box but excluding light fixtures. , installationof platform light poles: the scope of work includes installation ofplatform light poles with 4 way flp / wp jb including all sundry material as required, painting, welding and all structural works, with all labour and tools , as per the approved drawings, specifications of this tender and directions of engineer in charge. the scope of work also includes installation of cable from fixture to junction box. the scope of work also includes shifting of lighting pole within the cpcl premises to the site as per the direction of engineer in charge. , street light fixtures: the scope of work includes supply of led street light fitting, min. 70w equivalent to crompton model lstp 72 cdl in the existing street light pole. ip66, lumen >100 lm / w, as per the approved makes listed in the tender and necessary mounting accessories, suitablecable glands and support structures, as per the specifications of this tender and directions of engineer in charge. , flp well glass light fixtures: the scope of work includes supply of min. 40w flp well glass led lights of baliga / flexpro / fcg or any other approved makesuitable for mounting with platform poles including supply of suitable flp double compression cable glands, as per drawings and specifications attached with the tender and directions of engineer in charge. , wp well glass light fixtures: the scope of work includes supply of min. 40w wp well glass led lights ofapproved makesuitable for mounting with platform poles including supply of suitable cable glands, as per drawings and specifications attached with the tender and directions of engineer in charge. , flood light fixtures: the scope of work includes supply of min. 100w led flood light equivalent to crompton greaves model, lfln 100 cdl / 60, ip66of approved make, as per the directions of engineer in charge. , flood light fixtures: the scope of work includes supply of 150w led flood light equivalent to crompton greaves model, lfln 150 cdl / 60, ip66of approved make, as per the directions of engineer in charge. , flameproof flood light fixtures:the scope of work includes supply ofmin. 150w led flameproof flood light of baliga / flexpro / fcg or any other approved make including supply of suitable flp double compression cable glands, as per the directions of engineer in charge. , installation oflight fittings: the scope of work includes installation, testing and commissioning of led or conventional bulkhead / well glass fitting / street light fittings / flood light fittings etc, including fixing of control gear, cable glanding, termination and connections in fixtures as per the directions of engineer in charge. , installation upto 6 meters , installation at a height more than 6 meters , removal & relocation of high mast: the scope of work includes the following: a ) dismantling of electrical fittings & cables from high mast and dismantling of high mast from the existing foundation and location b ) construction of foundation for high mast in the new location with suitable foundation bolt according to the existing mast. necessary calculations and drawings for foundation shall be done by the contractor c ) shifting and installation of light fixtures, fixture arangement, mast parts and all other relevant accessories from old location to new location within cpcl premises with all labour and material , as per the approved drawings, specifications of this tender and directions of engineer in charge. , for the above mentioned removal scope , for the above mentioned relocation & installation scope , supply of wp junction box: supply / fabrication of following type dust , vermin proof and weather proof junction / adaptor boxes complete with all fixing hardwares like supports, nuts & bolts, etc including painting.the scope includes all material required to complete the job, as per drawings & specifications of this tender and directions of engineer in charge. , weight of the unit upto 2 kg. , weight of the unit above 2 kg but upto 5 kg. , weight of the unit above 5 kg but upto 10 kg. , supply of flp junction box: supply of following type dust , vermin proof, weather proof and flame proof junction / adaptor boxes complete with all fixing hardwares like supports, nuts & bolts, etc including painting. the number of cable glands holes and cable terminals shall be as per the directions of eic. the scope includes all material required to complete the job, as per drawings & specifications of this tender and directions of engineer in charge. , supply of flp junction box with dimensionupto 420 mm x 420 mm equivalent to type db 31340a in fcg catalogue , supply of flp junction box with dimension above 420 mm x 420 mmto420 mm x 550 mm equivalent to type db 31340ab in fcg catalogue , supply of flp junction box with dimensionupto550 mm x 550 mm ( which are not included in s.no. 2260 and 2270 ) equivalent type to db 31340abs2 in fcg catalogue , civil & structural works , excavation: the scope of work includes excavation of earth for cable laying / laying of gi pipes / earth strip etc., in all types of soil including saturated soil, for a maximum depth of 1.5 m and width approximately 0.5 m, including shoring, shuttering and dewatering ( if necessary it shall be paid separately as per sor ) , backfilling and compacting in layers not exceeding 20 cm thick to the finished ground level, including consolidation and disposal of surplus earth , all complete with labour and tools, as per approved drawings, specifications of this tender and directions of engineer in charge. ( excavated trench dimensions shall be measured ) . , removal of sand from cable trench: the scope of work includes removal of sand from the cable trenchwithout any damage to the cableand disposing it, all complete with labour and tools, as per the specifications of this tender and directions of engineer in charge. , back filling of sand from cable trench: the scope of work includes filling of sand back to trench, all complete with all labour with required tools, as per the specifications of this tender and directions of engineer in charge. , slab removal & relaying: the scope of work includes removal of rcc slabplaced above the cable trench, handlingcarefully without any damage of the slab and cable beneath it and keeping it back in position after laying / removing the cable and sealing the same between rcc covers with cement & sand, including hydra crane ( if required ) , job complete in all respect with labours and tools, as per the specifications of this tender and directions of engineer in charge. , pcc floor cutting: the scope of work includes pcc floor cutting for providing gi conduit laying, earth flat laying, cable laying etc., all complete with labour and tools and the contractor shall carry out the necessary housekeeping in the area as per the specifications of this tender and directions of engineer in charge. , rcc demolishing: the scope of work includes demolishing r.c.c. work for gi pipe laying including stacking of steel bars and disposal of unserviceable material, all complete with labour and tools, as per approved drawings & specifications of this tender and directions of engineer in charge. , dewatering electrical pump: the scope of work includes pumping out of water, including dewatering water mixed with oil / sludge, etc. from cable trenches, depressions etc. by contractors own electrical pump, with cable, labour, hoses, consumables, etc., complete as per the specifications of this tender and directions of engineer in charge. , supply of gi sheet: the scope of work includes supply of gi sheet of 2 mm thick for push button station, field call station, welding receptacle, plant ldb etc as per the the directions of engineer in charge , fabrication & fixing of rainhood for motors: the scope of work includes fabrication and fixing of rainhoods using gi sheet including painting for following rating motors as per the directions of the engineer in charge. , upto 3.7 kw motor , above 5 kw to 18.5 kw , above 18.5 kw to 37 kw , above 37 kw to 55 kw , above 55 kw to 90 kw , above 90 kw to 200 kw , fabrication & fixing of rainhood for miscellenous items: the scope of work includes fabrication and fixing of rainhoods using gi sheet including painting for following miscellaneous items as per the directions of the engineer in charge. , push button stations , welding receptacle , plant ldb , street light jb , telephone / plant communication jb , sfu , structural steel: the scope of work includes supply, fabrication & erection of ms base frames, supports for switchgear, control panels and brackets for miscellaneous electrical equipments, cable tray and cable tray supports out of rolled ms sections, pipe, vertical raceways, plate etc., including welding, bolting, riveting, supply of necessary anchor bolts and grouting, etc., supply & drilling in rcc and fixing of metallic anchor fasteners for supporting cable trays and other miscellaneous switchgear, all complete with labour and materials, as per the specifications of this tender and directions of engineer in charge. , supply , fabrication & erection / installation , supply of paint and applying one coat of anti rust primer and two finished coats of approved synthetic enamel paint for structural steel, all complete with labour, tools and materials, as per the specifications of this tender and directions of engineer in charge. , brick work: the scope of work includes supply and laying of approved 2nd class bricks of thickness 75 mm in cable trench for cable protection as per approved drawings & specifications of this tender and directions of engineer in charge. , chequered plate: the scope of work includes supply, fabrication and installation of 6 mm thick ms chequered plate for covering floor cut outs / cable trenches, etc., including all labour and materials as per approved drawings & specifications of this tender and directions of engineer in charge. , cable markers: the scope of work includes supply and installation of cable markers for under ground cables with 14 swg enamelled steel plate with white letteringon jade green background inclusive of providing and fixingsupports and including all labour and material, as per the specifications of this tender and directions of engineer in charge. , providing and laying plain cement concrete ( pcc ) 1:4:8 by volume ( 1cement : 4 m sand:8 coarse aggregate ) with opc 53 grade and 40mm & down size graded crushed stone aggregates for all depths wherever required like in foundations, fillings , floors, pavements & ramps or any other works etc., including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete including cement cost etc, all complete as directed by engineer in charge. , providing and laying of reinforced cement concrete ( rcc ) 1:1.5:3 by volume ( 1cement: 1.5 m sand:3 aggregate ) with opc 53 grade and 20mm and down size graded crushed stone aggregate materials for sub structure upto plinth beam levelfor all depths including pavement, machine mixing, curing, consolidating with vibrator, cement cost etcall complete as per instructions of engineer in charge excluding cost of shuttering and reinforcement. , dismantling: , dismantling of switch & sockets: the scope of work includes disconnection and dismantling of all types of switches, sockets and plug points without damage and returning them to our stores or any other place or site within the premises as decided by the engineer in charge, all complete with labour and tools , as per the specifications of this tender and directions of the engineer in charge. , dismantling of trays: the scope of work includes dismantling of following sizes of slotted / ladder type gi cable trays along with straight length elbows, tees, crosses, couplers plates etc., including, cutting, grinding and any other jobs required to dismantle, without any damage and returning it to stores or any other place or site within premises, all complete with labour and tools, as per the specifications of this tender and directions of the engineer in charge. , width upto 300 mm , width above 300 mmbut upto 600 mm , width above 600 mmbut upto 800 mm , dismantling of electrical wiring: the scope of work includes dismantling of electrical wiring ( comprising of single or twin core pvc wires upto 6 sq.mmand single earth wire upto swg ) along with its connected accessories including conduits , casings etc, as per the specifications of this tender and directions of engineer in charge. , dismantling of electrical flp / wp fittings: the scope of work includes disconnection and dismantling of surface / channel / wall / steel structures mounted wp / flp type fittings such as lighting fixtures, push button stations / motor control stations, junction boxes, welding sockets, lighting panels convenience outlets / convenience outlets with built in transformer etc. all complete without damage and returning them to cpcl stores or any other place or site within the premises, including dismantling of any supports, poles, frames or any other structures related to the fittings, as per the specifications of this tender and directions of engineer in charge. , weight of the unit upto 2 kg. , weight of the unit above 2 kg but upto 5 kg , weight of the unit above 5 kg but upto 10 kg , weight of the unit above 10 kg but upto 20 kg , dismantling of platform lighting poles: the scope of work includes disconnection and dismantling of platform light poles ( upto 3 metres height ) along with fittings and shifting it to the stores or to a new location including disconnection of power cable, removal of lighting fixtures and jbs without damage with all labour and tools and as per the specifications of this tender and directions of engineer in charge. , dismantling of street lighting poles: the scope of work includes disconnection and dismantling of street light poles along with fittings and shifting it to the stores or to a new location including disconnection of power cable , dismantling of foundation, excavation, removal of lighting fixtures and jbs without damage with all labour and material and as per the specifications of this tender and directions of engineer in charge. the scope of work includes arranging of necessary heavy duty vehicles like crane, tractor and trailer etc. as required. , dismantling of ht / lt switchgear ( 6.6 kv / 415 v ) : the scope of work includes dismantling of ht panels, lt panels, ups or any other panels as given below, ( i ) including electrical isolation ( i.e. ) disconnection of ht / lt / control cables and deglandingby competent personnel from connected lines ( under the supervision of valid licensed person ) , ( ii ) removal of copper / aluminium bus bars ( both horizontal and vertical ) in the ht / lt panel, ( iii ) removal of all switchgear components like cts, pts, fuses, mcbs, switches, bus bar supports ( insulators ) , relays, terminal boxes, selector switches, transducers, meters, indication lamps, interconnecting wires, nuts, bolts etc. from the dismantled panels. ( iv ) the scope includes dismantling job pretaining to 6.6kv / 415 breakers and shifting to any location within cpcl premises using contractor’s own equipments, tools, tackles, consumables and laboursas per the specification of this tender and directions of engineer in charge. tractor with trailor and hydra charges shall be paid as per the sor based on usage. note: each indicates one feeder and its cable chamber , weight upto 100 kg , above 100 kg upto 500 kg , above 500 kg upto 1000 kg , above 1000 kg upto 1500 kg , dismantling of ht softstarter ( 6.6 kv ) : the scope of work includes dismantling of ht softstarter of weight upto 3500 kg as given below, ( i ) including electrical isolation ( i.e. ) disconnection of ht / lt / control cables and deglandingby competent personnel from connected lines ( under the supervision of valid licensed person ) , ( ii ) removal of copper / aluminium bus bars in thepanel, ( iii ) removal of all switchgear components like cts, pts, fuses, mcbs, switches, bus bar supports ( insulators ) , relays, terminal boxes, selector switches, transducers, meters, indication lamps, interconnecting wires, nuts, bolts etc. from the dismantled panels. ( iv ) the scope includes dismastling job pretaining to 6.6kv breakers. within cpcl premises using contractor’s own equipments, tools, tackles, consumables and laboursas per the specification of this tender and directions of engineer in charge. the scope shall also include shifting of panel from substation to any other place inside the cpcl premises with all neccessary vehicles like tractor trailor, hydra, crane etc and manpower as per the requirements. , dismantling of structures: the scope of work includes dismantling of any support structures at ground level. the scope of work includes removal of structures from the ground support by welding / cutting, all complete with labour and tools, as per the specifications of this tender and directions of engineer in charge. , stencilling:the scope of work includes stencilling of letters / numbers on panels, cable drums etc., as per the directions of engineer in charge including all labour and materials. , letter / number of size up to 2 , letter / number of size above 2 to 4 , letter / number of size above 4 to 6 , dismantling of cables: the scope of work includes dismantling / pulling out the lt / ht, pvc / xlpe, power / control / telephone / computer, armoured / unarmoured cables of various voltage grades / types / sizes / makes from the trench ( upto 1.5 metres deep ) / pipes / structures / racks or trays, all complete with labour and tools. the scope also includes disconnection, deglanding, declamping of cables ( if required ) as per the directions of engineer in charge. , overall diameter upto 35 mm , overall diameter above 35 mm but upto 55 mm , overall diameter above 55 mm but upto 75 mm , overall diameter above 75 mm , cable dismantling and relaying:cable dismantling / pulling out of lt / ht, pvc / xlpe power / control / telephone / computer , armoured / unarmoured cables of various volatge grades / sizes from trench / pipes / structures / racks or trays and declamping, rerouting and relaying of cable for reglanding etc. as per the directions of engineer in charge. for 2c, 3c, 4c cables below rates of 3.5c cables will be applicable , all lv control cables and lv power cables upto 3.5c x25 sq.mm , lv power cables above 3.5c x 25 sq.mm upto 3.5c x 95 sq.mm , lv power cables above 3.5c x 95 sq.mm upto 3.5c x 185 sq.mm , lv power cables above 3.5c x 185 sq.mm upto 3.5c x 300 sq.mm , single core lv power cable upto 1000 sq.mm , single core ht cable upto 1000 sq.mm , ht cables from 3c x 120 sq.mm upto 3c x 185 sq.mm , ht cables from 3c x 240 sq.mm upto 3c x 300 sq.mm , retrieving of cables: the scope of work includes uncoiling of cables from damaged cable drums / retreiving of cables from broken drums / scrap, without causing any damage to the cables, all complete with labour and accessories required for the job, as per the specifications of this tender and directions of engineer in charge. job also includes disposal of the broken drums. necessary crane, tractor with trailer shall be arranged by the contractor. , overall diameter upto 25 mm , overall diameter above 25 mm but upto 35 mm , overall diameter above 35 mm but upto 45 mm , overall diameter above 45 mm but upto 55 mm , overall diameter above 55 mm but upto 75 mm , re rolling of healthy cables: the scope of work includes re rolling of healthy loose cables onto cable drums / empty drums, measuring and marking the length, providing end caps etc. without causing any damage to the cables and drums, all complete with labour and accessories required for the job, as per the specifications of this tender and directions of engineer in charge. ( cable drums will be provided by cpcl ) , overall diameter upto 25 mm , overall diameter above 25 mm but upto 35 mm , overall diameter above 35 mm but upto 45 mm , overall diameter above 45 mm but upto 55 mm , overall diameter above 55 mm but upto 75 mm , cable dressing:the scope of work includes cable dressing in trays, structures / channels / walls etc. dressing of cables shall be done with suitable clamps, fasteners of gi or aluminium at an uniform interval of 1 metre with all labour and materials, as per the instructions of eic , cable trays upto 150 mm wide , cable trays 300 mm to 450 mm wide , cable trays above 450 mm to 600 mm wide , cable trays above 600 mm to 750 mm , hiring of heavy duty vehicles , the scope of work includes hiring of 20 feet trailer with tractor ( on daily basis ) on workingdays on 8hrs shift, inclusive of driver, one assistant, consumables like diesel etc., with all safety instruments as per the specifications of this tender and directions of engineer in charge. all required tools, tackles, wire ropes, pulley blocks, belts, chains etc., for lifting, aligning, tying, stacking shall be arranged by contractor. 1vehicle day = 1 vehicle x 1 day ( 8hrs ) . , the scope of work includes hiring of 12t hydra ( escorts make f 17 model or equivalent ) on daily basis on working days on 8hrs shiift, inclusive of driver, one assistant, consumables like diesel etc., with all safety instrumentsas per the specifications of this tender and directions of engineer in charge. all required tools, tackles, wire ropes, pulley blocks, belts, chains etc., for lifting, aligning, tying, stacking shall be arranged by contractor. 1vehicle day = 1 vehicle x 1 day ( 8hrs ) . , manpower assistance: the scope of work includes supply of labour classified under the following categories as and when required, as per the specifications of this tender and directions of engineer in charge. , full day work , highly skilled , skilled , semi skilled , unskilled , over time work , highly skilled , skilled , semi skilled , unskilled , supply of inverter air conditioning unit: the scope of work includes supply of minimum 3 star inverter split air conditioning units of following tonnage of any approved make including any other hardwares and consumables required forcomplete installation as per specifications of this tender and directions of engineer in charge. , 1.5 tonnes , 2 tonnes , installation of air conditioning unit: the scope of work includes installation ofinverter or split air conditioning units with all related accessories as per specifications of this tender and directions of engineer in charge. , 1.5 tonnes , 2 tonnes , supply & installation of stabilizers: the scope of work includes supply , installation and commissioning of voltage stabilizers of below mentioned ratings of v guard or equivalent approved make, for ac unitsas per specifications of this tender and directions of engineer in charge. , 4 kva for 1.5 ton inverter ac , 5 kva for 2 ton inverter ac , ac repair & miscellaneous works: . , supply and fixing of stand for outdoor units of 1 / 1.5 / 2 ton split ac , supply and fixing of copper tube size 3 / 4 and 3 / 8 ( soft pipe ) for ac unit , the scope of work includes removal of window / split ac units as perscope of work and as per direction of engineer in charge , cost towards healthiness checking of ac unit ( window / split ac ) , gas charging of 1 / 1.5 / 2 ton split ac including all materials, labour and tools as per the directions of engineer in charge , supply, installation / commissioning of cassette unit: the scope of work includes supply, installation of indoor, factory assembled, cassette type air conditioning unit, rotary / scroll compressors, evaporator, remote air cooled condenser coil ( outdoor unit ) , refrigeration components, thermostats, controls, diagnostics, safety devices, accessories and suitable for operation in high ambient temperatures ( upto 115 deg f ) and coastal environments; indoor and outdoor units shall be factory pressure tested, run tested and supplied inclusive of full operating charge of gas.the capacity as follows. supply and installation shall be as per the specifications of this tender and directions of engineer in charge. , supply of 1.5 tr cassette type air conditioner , supply of 2.0 tr cassette type air conditioner , installation / commissioning of 1.5 tr cassette type air conditioner , installation / commissioning of 2.0 tr cassette type air conditioner , fire proof coating of cables , supply of hilti or equivalent make indoor application fire proof paint for 40 minutes fire retardant capacity for all cables cp678 ( weight of 20 kgs each box ) , supply of hilti or equivalentmake outdoor application fire proof paint for 40 minutes fire retardant capacity for all cables cp679a ( weight of 20 kgs each box ) , applying of fire proof paint over cables as per the directions of engineer in charge inclusive of all consumables & labour required , supply of meters / transformer : the scope of work includes supply of following type of meters / transformers as per approved vendor list, specifications of this tender and directions of engineer in charge: , three phase multifunction meter, ac 110v, 230v, 440 v ( make: rishab / schneider / conzerv / equivalent ) , programmable multifunction transducer ( rishabh m40 or equivalent ) , aux. supply: 85 230v ac / dc , analogue ammeter ( ae / rishab / schneider / meco / equivalent ) , analogue voltmeter ( ae / rishab / schneider / meco / equivalent ) , ht panel testing and commissioning: the scope of work shall include arrangement of manpower along with all tools, consumables & testing equipments to site for ( a ) carrying out secondary injection testing of protection relays ( b ) injection testing of 6.6kv current transformers ( c ) ht breaker servicing & testing including buffer replacement, measuring of crm, closing / tripping time etc ( d ) panel wiring checks including retermination, dressing as required the scope of work also includes submission of test reports and as built drawings as per the specification of tender and engineer in charge , differential stability test: the scope of work includes carrying out differential stability test for transformers, cables, ht busincluding supply of manpower along with all tools & testing equipments, as per the directions of engineer in charge . the scope of work also includes submission of test reports and as built drawings , lt panel testing and commissioning ( breaker feeder ) : the scope of work shall include arrangement of manpower along with all tools, consumables & testing equipments to site for ( a ) carrying out secondary injection testing of protection relays ( b ) injection testing of 415 v current transformers ( c ) measurement of ir values ( d ) lt breaker servicing & testing including buffer replacement, measuring of crm, closing / tripping time etc ( e ) panel wiring checks including retermination, dressing as required the scope of work also includes submission of test report and as built drawings as per the specification of tender and engineer in charge , lt panel testing and commissioning ( contactor feeder ) : the scope of work shall include arrangement of manpower along with all tools, consumables & testing equipments for ( a ) carrying out secondary injection testing of protection relays ( b ) injection testing of 415 v current transformers ( c ) measurement of ir values ( d ) panel wiring checks including retermination, dressing as required the scope of work also includes submission of test report and as built drawings as per the specification of tender and engineer in charge , transformer testing: the scope of work includes testing of transformers including all labour and materials, as per the specifications of this tender and directions of engineer in charge and shall submit the test reports. testing of transformer shall include the following test as a minimum requirement: *transformer winding resistance measurement *transformer ratio test *checking various alarms and trips *testing of the bucholz relay *oil breakdown voltage testing *measurement of insulation resistance *dielectric tests of transformer *tests on on load / off load tap changer *oil pressure test on transformer to check against leakages past joints and gaskets , cable hipot testing: the scope of work shall include arrangement of manpower along with all tools, consumables & testing equipments for cable hipot testing of 6.6 kv cables and submission of test reports as per the direction of engineer in charge. each shall indicate each cable. , numerical relay testing: the scope of work shall include arrangement of manpower along with all tools, consumables & testing equipments for numerical relay testing . the scope also includes submission of test reports as per the directions of engineer in charge.the scope of work shall include arrangement of manpower along with all tools, consumables & testing equipments , ht breaker testing :the scope of work includes ht breaker testing includingmeasuring of crm, closing / tripping time etc all complete with labour and materials as per the directions of engineer in charge. the scope of work shall include arrangement of manpower along with all tools & testing equipments. , lt breaker testing :the scope of work includes lt breaker testing includingmeasuring of crm, closing / tripping time etc all complete with labour and materials as per the directions of engineer in charge. the scope of work shall include arrangement of manpower along with all tools & testing equipments. , ht breaker servicing :the scope of work includes ht breaker servicing includingbuffer replacement all complete with labour and materials as per the directions of engineer in charge. the scope of work shall include arrangement of manpower along with all tools. , lt breaker servicing :the scope of work includes lt breaker servicing includingbuffer replacement all complete with labour and materials as per the directions of engineer in charge. the scope of work shall include arrangement of manpower along with all tools. , the scope of work includes supply and installation of zip type heat shrinkable outer sleeves for 6.6 kv / 11kv cables as per the details below, specifications of this tender and directions of engineer in charge: , overall diameter above 40mm upto 110mm, standard length 965mm , overall diameter above 57mm upto 145mm, standard length 1100mm , the scope of work includes supply of self amalgamating ht tapes of scapa or equivalent make, as per the directions of engineer in charge , rubber mat: the scope of work includes supply and laying of 900 mm wide safety insulation mats complying to is 15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable indian or international standards and cea guidelines and as per directions of engineer in charge. , 3.3 kv grade. , 11 kv grade. , the scope of work includes supply of following eqiupments as per approved vendor list, specifications of this tender and directions of engineer in charge: , led indication lamps, wide band ( 24 240v ac / dc ) , siemens / l&t / teknic / equivalent make , local / remote selector switch of salzer / kaycee / equivalent make , the scope of work includes supply of fm1 / quartz time switch 240v ac base / din mounting as per the specification of this tender and engineer in charge , the scope of work includes supply of digital time switch 240v ac base / din mounting as per the specification of this tender and engineer in charge , erection and dismantling of steel scaffolding:erection and dismantling of steel scaffolding at the required locations as directed by engineer in charge ( e.i.c ) using supply of 1.5 dia steel tubular pipes with suitable clamping arrangement, providing steel gratings at the required locations firmly tied on to the scaffolding pipes and to the satisfaction of e.i.c and removal / dismantling of the steel scaffolding materials on completion of the job. the job also includes supply of scaffolding materials, all types of tools andtackles, lifting arrangements like chain pulley blocks, all consumables and required labour to complete the job in all respects, including transportation of materials and steel gratings up to the work site. , erection and dismantling upto 5 meters height of scaffolding , erection and dismantling above 5 meters upto 10 meters height of scaffolding , erection and dismantling above 10 meters upto 20 meters height of scaffolding , shifting of package substation: the scope of work includes dismantling, shifting and re installation of existing package substationincluding all labour and tools, as per the specifications of this tender and directions of engineer in charge. the scope includes arranging of necessary crane, tractor, trailor, slings etc.by the contractor but excludes civil jobs for re installation. , supply of transformer oil : the scope of work includes the supply of transformer oil as per is 335 standard. routine and type test certificate shall be submitted along with supply of transformer oil , transformer oil filtration: the scope of work includes charges for transformer oil filtration per litre per circulation as per the tender document. the scope also includes testing of initial and final ( after filtration ) breakdown values bdv of transformer oil, transportation charges for filter machine etc. ( cost shall be inclusive of vehicle transportation charges, retention charges ( if any ) ) , supply of wp cable gland: the scope of work includes supply of weather proof cable glands as per the specifications of this tender and directions of engineer in charge. , overall diameter upto 19 mm ( 0.75 inch ) , overall diameter above 19 mm but upto 25 mm ( 1.0 inch ) , overall diameter above 25 mm but upto 32 mm ( 1.25 inch ) , overall diameter above 32 mm but upto 38 mm ( 1.5 inch ) , overall diameter above 38 mm but upto 51 mm ( 2.0 inch ) , overall diameter above 51 mm but upto 64 mm ( 2.5 inch ) , overall diameter above 64 mm but upto 76 mm ( 3.0 inch ) , supply of flp cable gland: the scope of work includes supply of double compression flameproof cable glands as per the specifications of this tender and directions of engineer in charge. , overall diameter upto 19 mm ( 0.75 inch ) , overall diameter above 19 mm but upto 25 mm ( 1.0 inch ) , overall diameter above 25 mm but upto 32 mm ( 1.25 inch ) , overall diameter above 32 mm but upto 38 mm ( 1.5 inch ) , overall diameter above 38 mm but upto 51 mm ( 2.0 inch ) , overall diameter above 51 mm but upto 64 mm ( 2.5 inch ) , overall diameter above 64 mm but upto 76 mm ( 3.0 inch ) , supply of monobloc pumps: the scope of work includes the supply of monobloc pumps of 1 hp along with required accessories as per the specification of this tender and directions of engineer in charge , supply of trefoil clamp: the scope of work includes the supply of trefoil clamp along with required accessories as per the specification of this tender and directions of engineer in charge , supply of flexible cables: the scope of work includes supply of unarmoured flexible copper cable, pvc insulated as per the specifications of this tender and directions of engineer in charge. , 3c x 1.5 sq.mm , 3c x 2.5 sq.mm , 4c x 2.5 sq.mm , 4c x 4 sq.mm , 4c x 6 sq.mm , supply of ladder: the scope of work includes supply of min. 8 feet frp ladder as per the specification of this tender and directions of engineer in charge , supply of distillation water unit: the scope of work includes supply of distilled water still with three heaters, heater details: 6 kw, 230 v, capacity : 8 litres / hr , servicing of ht megger: the scope of work includes servicing of ht megger with necessary parts and battery replacement as per the specification of this tender and directions of engineer in charge , shifting of scrap / miscellaneous items: the scope of work includes shifting of scrap / miscellaneous items anywhere within cpcl premises, all complete with labour and tools, as per the specifications of this tender and directions of engineer in charge. => limited...

Council Of Scientific And Industrial Research - Tamil Nadu

33147952 power supply augmentation to the proposed equipments in btf ( building ) at csir cecri, karaikudi ( phase i ) wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 2 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 3 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 4 supplying and laying 25 mm x 5 mm g.i strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm ) 5 providing and laying earth connection fromearth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 6 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 7 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 8 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. 9 above 35 sq. mm and upto 95 sq. mm 10 above 95 sq. mm and upto 185 sq. mm 11 layingandfixingofonenumberpvcinsulatedandpvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 12 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) 13 above95sq.mmandupto185sq.mm ( clampedwith 25 / 40x3mm ms flat clamp ) 14 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 15 3y x 35 sq. mm ( 32mm ) 16 3y x 50 sq. mm ( 35mm ) 17 3y x 150 sq. mm ( 50mm ) 18 3y x 400 sq. mm ( 82mm ) 19 excavationforcabletrenchesinsoftsoil, depthupto1.2m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable / pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. 20 providingandlayinginpositioncementconcrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) in foundation of pump, dg set etc including form work etc as required. 21 cast iron body earthing :providing cast iron pipe earth pit with 2000mm long 100mm dia 7mm thick cast iron pipe including excavation, refilling with salt, charcoal, natural soil and providing masonry cover etc., complete in all aspects as required. 22 mv panel battery testing facility : supply, erection testing and commisioning of floor mounting cubicle type mv panel fabricated out of 14 swg crca sheet steel, complete with required ms frame of adequate strength, painintg etc., conforming to the enclosed specifications and comprising the following main bus bar of 400 a, tpn, electrolytic copper bus, 3 phase of 50 x 6 mm per phase, 50x3 mm copper bus bar for neutral and 2 runs of 20x3mm copper bus allaround the panel for earth, [ please refer enclosed provisional drawing and the panel shall be conforming to ie rules, is:8623 / 93, cea & cpwd guideance ] etc., as required. incommer: 1 no 400a, tp&n, 415v, 50hz, 36 / 50ka, tmpu mccb with adjustable thermal, fixed magnetic releses along with suitable front operted handle, spreader links and phase barriesrs simialr to dpx3 630 series of legrand make or equivalent in schneider / siemens / mg / abb. 1 no. of multifunction energy meter to be mounted in the panel for measuring the electrical parameters ( vifpe ) as required.make l&t, ae, hpl socomec, krykard or equivalent as approved by the department. 1set of square flush type instrument meters confirming to is:1248 for accuracy and shall be suitably protected with mcb / fuses as per standards. misc voltmeter scaled ( 0 600v ) and ammeter of 600a range.make : ae / imp / mecco 1 set of voltmeter and ammeter selector switch 3 nos of indication lamps of led type with toggle switch. 3 nos of potential fuses and cts as required. 1 set of blank gland plate outgoing: 3 nos 200a, tp&n, 415v, 50hz, 25ka, tmpu mccb with adjustable thermal, fixed magnetic releses along with suitable front operted handle, spreader links and phase barriesrs simialr to dpx3 250 series of legrand make or equivalent in schneider / siemens / mg / abb. 5 nos 100a, tp&n, 415v, 50hz, 16 / 18ka, tmpu mccb with adjustable thermal, fixed magnetic releses along with suitable front operted handle, spreader links and phase barriesrs simialr to dpx3 160 series of legrand make or equivalent in schneider / siemens / mg / abb. note: all the incoming units are to be provided with door interiors, phase barriers and protection guards ( on the incoming side ) the non conducing metallic parts of the switch gear shall be double earthed. all interior tappings & connctions shall also be electrolytic copper.incomer terminations shall be suitable for receivig underground cables. cable terminations shall invariably be through terminal blocks ( polymide of superior ) or brought out solid terminals. ( a ) supply 23 ( b ) erection, testing and commissioning of the above panel including removing the existing change over switch unit, existing cables, along with making provision for the cable trenches, cable looses, excavation, other allied civil works etc and angle iron channels of required size& qunatity for housing the panel as per standards, complete in all aspects as required as per site condition. 24 8 way mccb vtpn db:supplying and fixing 12 way surface / recess mccb mounting, 415 volts, vertical type tpn mcb distribution board ( with wire way / cable end box ) of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copperbusbar, commonneutrallink, earthbar, dinbarfor mounting mcbs, along with 100 a, 16 / 18 ka tpn mccb, phase barrier and spreaders for incomer, interconnection between db incomer and the bus bars / existing mains shall be made with copper cables of appropriate rating as required. the vtpn db shall be mounted on a adequate size angle / flat and grouted / fixed ( drilling, cutting welding painting etc ) firmly in the existing wall / existing base channel as required as per site condition complete in all aspects. the above db shall include the following c series, 10 ka mcbs in the out going circuits tp mcb 63a 2 nos tp mcb 32a 3 nos sp mcb 6 32a 6 nos . sp mcb 40 63a 3 nos. blanking plates as required. make : abb / legrand / schneider / siemens / hager or equivalentsubject to the approval of the department. 25 12 way mccb vtpn db:supplying and fixing 12 way surface / recess mccb mounting, 415 volts, vertical type tpn mcb distribution board ( with wire way / cable end box ) of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copperbusbar, commonneutrallink, earthbar, dinbarfor mounting mcbs, along with 160 a, 16 / 18 ka tpn mccb, phase barrier and spreaders for incomer, interconnection between db incomer and the bus bars / existing mains shall be made with copper cables of appropriate rating as required. the vtpn db shall be mounted on a adequate size angle / flat and grouted / fixed ( drilling, cutting welding painting etc ) firmly in the existing wall / existing base channel as required as per site condition complete in all aspects. the above db shall include the following c series, 10 ka mcbs in the out going circuits tp mcb 63a 4 nos tp mcb 32a 4 nos sp mcb 6 32a 12 nos blanking plates as required. make : abb / legrand / schneider / siemens / hager or equivalentsubject to the approval of the department. 26 removing & shifting the existing 160 kva generator: reomving and shifting the existing 160 kva generator along with the frame and the cahnge over panel by engaging all means and materials as required as per site condition including crane charges if any from the btf to the stroes section or any other areawithin the institute premises as directed by the engineer in charge....

Tamil Nadu Tea Plantation Corporation Limited - Tamil Nadu

33147072 supply of electricals 1 250 kva kirloskar cummins genset b check kit 2 250 kva kirloskar cummins genset governer cable 3 320 kva greaves genset b check kit 4 f 6 381.03.000 expansion bellow 5 f 6 618.01.000 expansion bellow 4 6 f 6 381.04.000 joint between bellow and gas out 7 f 6 026.03.000 joint of exhaust manifold 8 50.080.10.000 s.steel out m 10 a isi 30 9 50.006.08.000 nut m 8x1.25 gr 8.8 10 06.436.01.000 spin on filter for lub oil 11 48.117.04.000 fuel filter element pre 12 48.117.05.0.00 fuel filter micro 13 lub oil filter ( for 250 kva genset kirlosker make ) with rubber washer 14 diesel filter ( for 250 kva genset kirlosker make ) with rubber washer 15 diesel pre filter ( for 250 kva genset kirlosker make ) with rubber washer 16 lub oil filter ( for 320 kva genset kirlosker make ) with rubber washer 17 diesel filter ( for 320 kva genset kirlosker make ) with rubber washer 18 diesel pre filter ( for 320 kva genset kirlosker make ) with rubber washer 19 lub oil filter ( for 250 kva genset greeves make ) with rubber washer 20 diesel filter ( for 250 kva genset greeves make ) with rubber washer 21 diesel pre filter ( for 250 kva genset greeves make ) with rubber washer 22 lub oil filter ( for 320 kva genset greeves make ) with rubber washer 23 diesel filter ( for 320 kva genset greeves make ) with rubber washer 24 diesel pre filter ( for 320 kva genset greeves make ) with rubber washer 25 lub oil filter ( for 320 kva genset powerica make ) with rubber washer 26 diesel filter ( for 320 kva genset powerica make ) with rubber washer 27 diesel pre filter ( for 320 kva genset powerica make ) with rubber washer 28 air filter ( 250 kva genset kirlosker make ) 29 air filter ( 320 kva genset kirlosker make ) 30 air filter ( 250 kva genset greeves make ) 31 air filter ( 320 kva genset greeves make ) 32 f6 729.07.0.00 main element for 250 kva aircleaner 33 f 6 729.08.0.00 adwrt wkwnwbr die 150 kva aircleaner 34 50. 508.05.0.00 copper washer 8x12 35 50. 508.11.0.00 copper washer 14x18 36 50. 006.10.000 nut m 10 x 1.5 gr 8.8 37 50. 508.10.0.00 copper washer 12x18 38 50. 505.08.0.00 spring washer m8 39 f 6 537.02.0.00 starer ring t / c no. 68 f 636 2360 40 250 kva avr alternator stampford 41 320 kva avr kirloskar alternator 42 320 kva water cooling pipe connecting 43 rubber hoses complete set 11 kv ht transformer structure spares 44 11 kv ab switch droped out fuse moving and stable contact with hylam bar set 45 copper riben 1 / 4 x 1 x 1 mtr 46 lightning arrester 11 kv 47 lightning arrester 22 kv 48 lightning arrester 30 kv 49 silica gel 50 transformer oil 51 11 kv hand gloves 52 transformer breather 53 11 kv pin type insulator 54 11 kv ab switch siemens make 55 11 kv ab switch spares male & female contact, lever etc., siemens make 56 800 amps acb l&t make u / v coil 230 v 57 800 amps acb l&t make shunt coil 230 v circuit breaks 58 mccb l & t make 630 a ( dth 630 ) 59 mcb 1 p 6 a 60 mcb 1 p 10 a 61 mcb 2 p 16 a 62 mcb 2 p 32 a 63 mcb 3 p 16 a 64 mcb 3 p 25 a 65 mcb 3 p 32 a 66 mcb 3 p 40 a 67 mcb 3 p 50 a 68 mcb 1 p 20 a 69 mcb 4 p 63 a 70 mcb 2 pole 16 amps 71 mcb single pole 6 amps 72 mcb single pole 15 amps 73 mcb single way metal box ( adapter ) 74 mcb 2 way metal box ( adapter ) 75 mcb 2 way metal box ( without adapter ) 76 mcb 4 way metal box ( without adapter ) 77 mcb distribution boards 12 way hawks / l & t 78 mcb distribution boards 8 way l & t 79 mcb distribution boards 6 way 80 m 16 acb, top fixed contactor ( g.e power control make ) m pact 610 l & t 81 m 16 acb, bottom fixed contactor ( g.e power control make ) m pact 610 82 m 16 cluster contactor 83 spare kit fo r 600 a o.c.b easun fb 3 84 apfc for 50 kvar 85 25 kvar power capacitor siemens 86 15 kvar power capacitor siemens 87 10 kvar power capacitor siemens 88 male and female contactor for 800a acb mpcb 89 mpcb control and switch gear contactors make tcms 63 90 mpcb control and switch gear contactors make tcms 32 91 mpcb for 2 hp 92 mpcb for 5 hp 93 mpcb for 25 hp 94 mpcb for 40 hp main switches 95 400 a fb type moving contact 96 400 a fb type switch mechanisam 97 630 a fb type moving contact 98 630 a fb type moving bank 99 g. e 400 a mainswitch moving contact set ( type cmm ) 100 g. e 400 a mainswitch fixed contact set ( type cmm ) 101 g. e 250 a mainswitch moving contact set ( type cmm ) 102 g. e 250 a mainswitch fixed contact set ( type cmm ) 103 dowel pin ( for g.e switch on / off lever ) 104 125 a main switch l & t fb type 105 250 a main switch l & t fb type 106 vsb type hrc fuse 400 a hn size ii l & t 107 hrc fuse link 200 a ( tsd ) l & t 108 hrc fuse link 250 a l & t 109 hrc fuse link 300 a l& t 110 hrc fuse link 400 a l& t 111 hrc fuse link 630 a l& t 112 hrc fuse link 315 a l& t 113 hrc fuse link 100 a l& t 114 hrc fuse link 63 a l& t 115 hrc fuse link 80 a l& t 116 hrc fuse link 10 a type ns1a make ee 117 hrc fuse link 14 x 51 l & t 10 a 118 hrc fuse link 16 a 119 hrc fuse link 32 a 120 c & s mccb 125 a cs c4 n3 121 back lite fuse unit 20 a 122 back lite fuse unit 10 a 123 sm 125 ee make fuse unit hrc type 124 63 a back light fuse unit 125 back lite fuse carrier unit 125 a ( type sm 125 h ) 126 on push button ( bch ) 127 off push button ( bch ) 128 on push button ( with indicator ) 129 off push button ( with indicator ) 130 on push button ( teknic make ) 131 off push button ( teknic make ) 132 element on 133 element off 134 led indicator 230 v ( red, blue, yellow and green ) 135 bch limit switch 136 100 a isolator 137 63 a isolator 138 32 a isolator 139 32 a isolator mcb type 3pole standard make 140 63 a isolator mcb type 4 pole 141 100 a tp main switch ( rewireable ) 142 din rail set 143 15 a d.b fuse unit ( as per sample ) 144 16 a d.b fuse unit ( as per sample ) 145 63 a d.b fuse unit ( as per sample ) 146 32 a d.b fuse unit ( as per sample ) 147 100 a d.b fuse unit ( as per sample ) 148 100 a fuse unit ( as per sample ) 149 15 a top pin / 15 amps power plug 150 100 a stable contactor ( porclain ) 151 16 a fuse carrier ( porclain ) 152 volt meter selector switch 153 rotory switch 154 bed switch 155 15 amps toggle switch 156 16 a f / r switch gear handle & bracket 157 32 a moald fuse sitting unit 158 100 a u clamp with hylembar 159 32 a isolator base 160 25 a f / r switch 161 hrc fuse l & t 125 a type tsd 162 hrc fuse l & t 100 a type tsd 163 hrc fuse l & t 125 a size od 164 hrc fuse l & t 250 a type tsd 165 hrc fuse l & t 400 a 166 fbc switch l & t 3 pole 400 a 167 fbc switch l & t 3 pole 250 a 168 fbc switch l & t 3 pole 125 a 169 ml 3 fully automatic star / delta starter 170 mnx 45 fully automatic star / delta starter 171 mk 1 dol starter l & t 3 hp 440 v 172 sensor control timer 173 photo sensor 174 pull guard switch 175 32 a interior type siemens isolator 176 32 a mainswitch type sp 1.5 with hrc fuse ge 177 100 a stable & moving contact 440 v 3 phase 178 100 a stable & moving contact 179 63 a stable & moving contact 180 100 a 440 v fuse switch hrc with reutrel link ( encloser type ) 181 16 a ( 3 tn ) standard kupp 9 ka mcb 182 63 a tp hrc type stable and moving contact ee 183 200a tp hrc type stable and moving contact ee 184 300a tp hrc type stable and moving contact ee 185 400a tp hrc type stable and moving contact ee 186 32 a stable moving contact u clamp 187 fuse switches 32 a 440 v ( side handle ) 188 fuse switches 63 a 440 v ( side handle ) 189 630 a l & t stable and moving contact set 190 l & t fn 400 interiar type switch 191 l & t fn 100 interiar type switch 192 l & t fn 125 interiar type switch 193 l & t fn 63 interiar type switch 194 300 a 600v fuse switch combination make ee, type tf4pole stable and moving contact 195 200 a 600v fuse switch combination make ee, type tf4pole stable and moving contact 196 100 a 600v fuse switch combination make ee, type tf4pole stable and moving contact 197 63 a 600v fuse switch combination make standard, type tshf63 n intirior only contactors 198 siemens 3 tf 20 ( c.v 230 ) 199 siemens 3 tf 10 ( c.v 230 ) 200 siemens 3 tf 44 ( c.v 230 ) 201 siemens 3 tf 31 ( c.v 230 ) 202 siemens 3 tf 31 ( add on block nc / no ) 203 siemens 3 tf 35 ( add on block nc / no ) 204 siemens 3 tf 4422 oa 415 v 205 siemens 22 e 3 tb 41 170 a.o contactor block 206 siemens 3 ta 10 contactor 207 siemens 3 ta 10 olr 208 siemens 3 ua 19 11 a olr 209 siemens auxilary contact 3 tx 4001 2 a 210 siemens auxilary contact 3 tx 4010 2 a 211 siemens 3 ua 55 00 2r olr 32 40 a 212 siemens no volt coil 24 v 213 l & t ( add on block nc / no ) 214 l & t contactor mnx 9 ( c.v 230 v / c.v 440 ) 215 l & t contactor mnx 18 ( c.v 230 v / c.v 440 ) 216 l & t contactor mnx 32 ( c.v 230 v / c.v 440 ) 217 l & t contactor mnx 40 a 218 l & t contactor mnx 32 a 219 l & t contactor mnx 25 a 220 l & t contactor mn 12 ( c.v 230 v / c.v 440 ) 221 l & t contactor mn 32 ( c.v 230 v / c.v 440 ) 222 l & t contactor mn 16 ( c.v 230 v / c.v 440 ) 223 l & t contactor mn 45 ( c.v 230 v / c.v 440 ) 224 l & t auxilary contactor mnx az 225 l & t auxilary contactor mnx a 226 l & t auxilary contactor for mk 1 227 l & t stable and moving contact for mk 1 228 l&t controller sdz5 model star delta timer 229 pla ( 2c / o pmc 240 a 5 230 single phasing preventor sm301 231 vlt micro drive unit ( danfield make ) with hand on, off reset, auto on 232 pmd 01 phase monitoring device eapl make 233 digital preventor single phasing preventor ( with phase sequents & under voltage protection. 234 jainson limit switxh 10a 500 vac 1 no+1nc ( type jlsr ) 235 g.e make 150 a contactor ( c.k. 75 c ) 236 g.e make 150 a contactor ( c.k. 75 c ) ( add on block nc / no ) 237 bch 110 a contactor mce 15 mn3 238 bch 16 a contactor 239 bch 25 a contactor 240 bch 40 a contactor nhd 241 bch 40 a contactor mc 10 d 1, a3 series 242 bch 40 a contactor mc 10 d 1, a3 series ( add on block nc / no ) 243 control and switch gear contactors make 244 control and switch gear contactors make tc 1d 50 / 11 245 control and switch gear contactors make tc 1d 09 / 10 246 control and switch gear contactors make tc 1d 32 / 01 247 control and switch gear contactors make ta 1m add on block nc / no ) 248 control and switch gear contactors make ta 1d n 11 ( add on block nc / no ) 249 control and switch gear contactors make lai d 11 ( add on block nc / no ) 250 l & t make single phase preventor sm 301 251 bch freedom series 32 a ce 15 dn 4 230 / 415 252 bch freedom series 40 a ce 15 dn 4 230 / 415 253 bch freedom series 60 a ce 15 dn 4 230 / 415 254 bch freedom series ( add on block nc / no ) 255 bch 140 amps ( series a1 ) contactor coil voltage 230 volt / ac 256 bch 140 amps ( series a1 ) contactor no volt coil 257 olr 3 ua 19 1.5 to 2.5 a 258 olr 3 tf model 1 hp 259 olr 3 tf model 3 hp 260 olr 3 tf model 5 hp 261 olr 3 tf model 7.5 hp 262 olr 3 tf model 10 hp 263 olr 3 tf model 40 hp 264 olr 1.1 2.0 265 o.l.r 22 30 a 266 o.l.r 28 40 a 267 o.l.r r4 30 50 a 268 o.l.r r4 15 25 a 269 o.l.r 13.2 20 a 270 o.l.r mn2 2.5 4 a 271 o.l.r mn2 1.5 3 a 272 o.l.r mnx 32 16 22 a 273 o.l.r ml3 20 32 a 274 o.l.r ml3 13 21 a 275 o.l.r mk1 2.5 4 a 276 o.l.r mk1 6 9 a 277 bch olr 0.72 to 1.14 278 bch olr 0.42 to 0.72 279 bch olr 1.58 to 2.5 280 bch olr 8.9 to 13 281 bch olr 13.0 to 21 282 bch olr 20.0 to 32 283 bch olr 2.40 a 3.80 ( citation m type ) 284 bch olr 3.80 a 6.00 ( citation m type ) 285 bch olr 17.4 a 24.0 ( citation m type ) 286 bch olr 22 a 30.0 ( citation m type ) 287 bch olr 6 a 9.3 ( citation m type ) 288 ct type 24 a to 39 a 289 bch 230 v, 140 a spole m series contactor 290 bch olr 1.7 a 2.4 a ( freedom series d15 cr 22 ) 291 bch olr 3.5 a 5.0 a ( freedom series d15 cr 22 ) 292 bch olr 10 a 14.0 a ( freedom series d15 cr 22 ) 293 bch olr 24 a 32.0 a ( freedom series d15 cr 22 ) 294 bch olr 36 a 52.0 a ( freedom series d15 cr 22 ) 295 bch auxilary contact 296 auxilary contact blue slider 297 auxilary contact green slider 298 back light fuse unit 299 bch pneumatic timer ( 440 cv & 240 cv ) 300 electronic timer ( selec ) 800 psr model 415 volts 301 electronic timer series micon 22 s star delta 302 electronic timer on off timer ( 0 to 3 hours ) 303 timer 7 pu 60 20 304 et 100 timer 305 star delta timer 220 / 440 v 306 m.k. 1 contactor l & t make 307 bch no volt coil 308 mk l & t olr 4 to 6.5 a 309 ml 1 relay 2.5 to 4 a 310 l & t olr 0.5 1.5 311 l & t olr 1.5 2.5 312 l & t olr 9 13 313 ml 1 .5 spare kit 314 mk 1 no volt coil 440 volts 315 timer for ml 1.5 starter 316 ml 1.5 contactor 317 mk 1 spare kit 318 ml 2 relay 13 to 21 a 319 mk 1 relay 6 to 10 a 320 3 hp bch dol starter 321 siemens 25a contactor 322 abb contactor 10a, cv 230v 323 abb contactor 16a, cv 230v 324 abb contactor 32a, cv 230v 325 spare kit for ml 2 contactor 326 spare kit for ml 3 contactor 327 spare kit for ml 4 contactor 328 l & t ml 4 contractor 329 ml2 timer without coil 440 v 330 ml2 contactor 440 v ( l &t ) 331 ml3 contactor 440 v ( l &t ) 332 ml4 contactor 440 v ( l &t ) 333 ml3 combination coil 440 v ( l &t ) 334 ml 2 no volt coil 440 v ( l &t ) 335 3 a3 16 230 v contact block 336 remote control with key operation 337 t 25 du 1 amps olr 1.7 2.5 a 338 bch contactor spare kit 25 a 339 bch contactor spare kit 40 a 340 bch extention contact olr extention 341 bch extention contact contact extention 342 bch timer for star delta starter 440 v 343 l & t star delta starter encloser for mk 1 type 344 auxilary contact siemens ( 3tx4010 2a ) no / nc 345 tc tr 2d 65 olr 48 a to 65 a 346 tc tr 2d 09 olr 7a to 10 a 347 tc tr d 65 contactor no volt coil 348 tc tr 2d 09 olr 1a to 1.6 a 349 tc make mpcb ( tcms 32s ) 350 slm viberating fork level limit switch make sapcon 351 no volt coil 440 v for bch contactor 352 contactor 50 us 440 v ( yule make ) 353 spare kit 50 us ( yule make ) 354 no volt coil for 50 us yule contactor / 440 v 355 olr 20 32 a 356 olr 17 23 a 357 abb olr relay 1.7 2.4 a 358 abb olr relay 3.2 6 a 359 abb contactor with coil b 9, 30 10 360 no volt coil 440 v ml4 361 proximity sensor unit 12v ( with relay set ) 362 proximity sensor 12v 30mm dia 363 metal clad plug 230 v x 16 a 364 metal clad socket 230 v x 16 a lighting assessories 365 40 w tube light 366 tube light chock 367 80 w led street light fitting ( lamp ) 368 80 w bay light ( led ) 369 30 w jet lamp ( led ) 370 22 w bay light ( led ) 371 36 w bay light ( led ) 372 45 w street light with lightning protector ( led ) 373 12 w inverter lamp ( led ) 374 22 w batten light ( led ) 375 36 w batten light ( led ) 376 20 w flood light ( led ) 377 30 w flood light ( led ) 378 20 w bulb ( led ) 379 200 w bay light ( led ) 380 40 w led street light fitting ( lamp ) 381 2 x 36 w cfl street light fitting chock type 382 cfl bulb 32 w 383 cfl bulb 35 w cg spiral 384 cfl bulb 36 w 385 cfl bulb 65 w 386 s.v lamp 250 w fitting 387 s.v lamp 250 w chock 388 s.v lamp 150 w chock 389 s.v lamp 250 w ignitor 390 s.v lamp 250 w bulb 391 2.5 mfd capacitor 440 v 392 5.0 mfd capacitor 440 v 393 32 mfd capacitor 440 v ( for 250 w sv lamp ) 394 5 a x 2 core flexible copper wire 395 15 a x 4 core flexible copper wire 396 15 a x3 core flexible copper wire 397 7 / 16 pvc copper wire 398 7 / 20 pvc copper wire 399 1 / 18 pvc copper wire 400 3 / 20 pvc copper wire 401 1.5 pvc copper wire 402 2.5 pvc copper wire 403 4.0 pvc copper wire 404 tubelight pickup wire 405 tube light holder 406 insulation tape 1 / 2 407 3 / 4 steel grip make 408 empire tape 3 / 4 409 cotton tape 3 / 4 410 ht tape 3 / 4 411 brass holder 412 75 w spot light 413 geaser coil 414 1000 watts kettle elements 415 neptune make kwh meter voltage coil 416 5 a anchor make switch f / t type 417 15 a anchor make switch f / t type 418 16 a metal glade socket with plug 419 18 x 12 sintex make box 420 110 v pin head bulb 421 teknic make 2 lh br 200 panel indicator bulb set red yellow blue 422 slazer make ammeter select switch 423 electronic chock heavy duty 424 4 x 4 ms box 425 6 x 4 ms box 426 lighting db for 3 phase 440 v 32 a mcb with 4 outlet / phase 427 230 v 15 a power plug 428 5 a 5 pin socket 429 3 core x 0.5 sqmm flexible sensor cable 430 4 core x 2.5 sqmm flexible sensor cable 431 6 core x 0.5 sqmm flexible sensor cable 432 10 sqmm single stand copper wire 433 8 sqmm single stand copper wire 434 1 / 18 wire multi 435 pendant holder 436 3 / 4 contact pipe 437 metalic flexible hose 3 / 4 438 hylam sheet 3 mm thickness 439 hylam sheet 12 mm thickness 440 16 a kettle connector 441 bus bar supporter 442 flexible hose 1 443 metalic flexible hose 1 1 / 2 444 metalic flexible hose 2 445 metalic flexible hose gland 3 / 4 446 metalic flexible hose gland 1 447 metalic flexible hose gland 1 1 / 2 448 metalic flexible hose gland 2 449 ms box 4x4x4 450 ms box 6x4x4 451 ms box 10x8x4 452 ms box 12x10x4 453 led tube light ( suitable for 40w tube light fitting ) 454 led lamp street light ( fitting equalent for sv lamp 250 w ) 455 rubber hand gloves 22 kv 456 led tube bulb 2 12 watts ( industrial use ) 457 led tube bulb 4 18 watts ( industrial use ) 458 led tube bulb 4 20 watts ( industrial use ) 459 led bulb 15 watts 460 led emergnecy bulbs 9 watts 461 led high bay hbl series 60 watts ( pole mounting ) 462 led on / off push button with elementschneider make 463 keltron capacitor 20 / 40 mfd cables 464 3 x 50 sqmm aluminum armoured ug cable 465 3 1 / 2 x 50 sqmm aluminum armoured ug cable 466 3 1 / 2 x 85 sqmm aluminum armoured ug cable 467 3 1 / 2 x 120 sqmm aluminum armoured ug cable 468 3 1 / 2 x 185 sqmm aluminum armoured ug cable 469 3 1 / 2 x 240 sqmm aluminum armoured ug cable 470 3 x 35 sqmm aluminum armoured ug cable 471 3 1 / 2 x 35 sqmm aluminum armoured ug cable 472 3 x 25 sqmm aluminum armoured ug cable 473 3 1 / 2 x 25 sqmm aluminum armoured ug cable 474 3 x 16 sqmm aluminum armoured ug cable 475 4 x 16 sqmm aluminum armoured ug cable 476 3 x 4 sqmm aluminum armoured ug cable 477 2 x 4 sqmm aluminum armoured ug cable 478 4 x 4 sqmm aluminum armoured ug cable 479 3 x 6 sqmm aluminum armoured ug cable 480 3 x 10 sqmm aluminum armoured ug cable 481 4 x 6 sqmm aluminum armoured ug cable 482 240 sqmm cable socket ( copper ) flat 483 50 sqmm cable socket ( copper ) flat 484 10 sqmm cable socket ( copper ) flat 485 4 sqmm cable socket ( copper ) flat 486 16 sqmm cable socket pin / flat aluminum 487 25 sqmm cable socket pin / flat aluminum 488 35 sqmm cable socket pin / flat aluminum 489 50 sqmm cable socket pin / flat aluminum 490 70 sqmm cable socket pin / flat aluminum 491 95 sqmm cable socket pin / flat aluminum 492 120 sqmm cable socket pin / flat aluminum 493 185 sqmm cable socket pin / flat aluminum 494 240 sqmm cable socket pin / flat aluminum 495 300 sqmm cable socket flat aluminum 496 400 sqmm cable socket flat aluminum 497 3 x 4 sqmm copper ug cable 498 3 x 6 sqmm copper ug cable 499 3 x 10 sqmm copper ug cable 500 19 mm cable gland 501 25 mm cable gland 502 35 mm cable gland 503 22 mm cable gland 504 28 mm cable gland 505 38 mm cable gland 506 building copper lightening arrester spike, hevy duty 507 bare copper earth wire 14 swg 508 bare copper earth wire 10 swg 509 bare copper earth wire 8 swg 510 1 / 8 x 1 earth flat 511 1 / 4 x 1 earth flat 512 2 copper earth clip 513 crimping paste 100 gm winding materials 514 supper enameled winding copper wire 18 swg 515 supper enameled winding copper wire 18.5 swg 516 supper enameled winding copper wire 19 swg 517 supper enameled winding copper wire 19.5 swg 518 supper enameled winding copper wire 20 swg 519 supper enameled winding copper wire 20.5 swg 520 supper enameled winding copper wire 21 swg 521 supper enameled winding copper wire 21.5 swg 522 supper enameled winding copper wire 22 swg 523 supper enameled winding copper wire 22.5 swg 524 supper enameled winding copper wire 23 swg 525 supper enameled winding copper wire 24 swg 526 supper enameled winding copper wire 26 swg 527 supper enameled winding copper wire 27 swg 528 supper enameled winding copper wire 28 swg 529 supper enameled winding copper wire 29 swg 530 supper enameled winding copper wire 30 swg 531 supper enameled winding copper wire 33 swg 532 insulating varnish ( dr. beck ) 533 10 a tinned copper fuse wire 534 30 a tinned copper fuse wire 535 40 a tinned copper fuse wire 536 60 a tinned copper fuse wire 537 100 a fuse wire ( tinned copper ) 538 30 a fuse wire ( tinned copper ) 539 copper cable lug sd 6 ( flat / pin ) 540 copper cable lug sd 16 ( flat / pin ) 541 copper cable lug sd 25 ( flat / pin ) 542 millimx paper 10 mills 543 millimx paper 8 mills 544 leatheriod paper 8 mills 545 f class leatheriod paper 546 test lamp doom 547 fibre glass sleeve 1 sqmm 548 fibre glass sleeve 2 sqmm 549 fibre glass sleeve 3 sqmm 550 fibre glass sleeve 4 sqmm 551 fibre glass sleeve 5 sqmm 552 fibre glass sleeve 6 sqmm 553 fibre glass sleeve 7 sqmm 554 fibre glass sleeve 8 sqmm 555 fibre glass sleeve 10 sqmm 556 fibre glass wire 1.5 sqmm 557 fibre glass wire 2 sqmm 558 fibre glass wire 2.5 sqmm 559 fibre glass wire 4 sqmm 560 fibre glass wire 5 sqmm 561 fibre glass wire 6 sqmm 562 fibre glass wire 8 sqmm 563 fibre glass wire 10 sqmm 564 soldering paste flux 565 soldering lead ( rate per kg ) 566 wooden wedges motor spares 567 motor cooling fan pvc 1 hp 568 motor cooling fan pvc 2 hp 569 motor cooling fan pvc 3 hp 570 motor cooling fan pvc 5 hp 571 motor cooling fan pvc 7.5 hp 572 motor cooling fan pvc 10 hp 573 motor cooling fan pvc 20 hp 574 motor cooling fan pvc 25 hp 575 motor cooling fan aluminum 25 hp 576 motor cooling fan aluminum 30 hp 577 motor cooling fan pvc 40 hp 578 motor cooling fan aluminum 40 hp 579 motor terminal block 40 hp 580 motor terminal block 20 hp 581 motor terminal block 25 hp 582 motor terminal block 30 hp 583 motor terminal block 7.5 hp 584 motor terminal block 5 hp 585 motor terminal block 3 hp 586 motor terminal block 2 hp 587 motor terminal block 1 hp 588 25 hp motor end cover 589 5 1 / 2 x od x 2 a pulley 590 2 1 / 2 x od x 2 a pulley 591 5 x od x 2 b pulley 592 4 1 / 2 x od x 2 b pulley 593 3 1 / 2 x od x 2 b pulley bolt nut 594 3 / 16 x1 gi bolt nut tvs 595 6 mm x 75 mm gi bolt nut tvs 596 10 mm x 50 mm gi bolt nut tvs 597 1 / 4 x 1 gi bolt nut tvs 598 4 mm x 30 mm gi bolt tvs 599 6 mm x 50 mm gi bolt tvs 600 8 mm x 75 mm gi bolt tvs 601 1 / 2 x4 gi bolt nut tvs 602 concrete nail 1 603 concrete nail 2 meters 604 0 80 a 5 x5 meter 605 energy meter ( bhel ) spt 4w type pm 34 md 300 rev / kwh 606 digital temperature scanner model ts605 607 sensor for digital temperature scanner model ts 605, ( fe k prop ) for kilburn drier ) 608 digital ammeter 4 x4 ( 0 to 600 a ) emron make 609 volt meter ( 0 500 a ) ( electronic ) 4x4 610 power factor meter ( electronic ) 4x4 611 clamp meter, make crompton greeves 612 ct 50 / 5 613 ct 100 / 5 614 ct 200 / 5 615 ct 300 / 5 616 ct 400 / 5 617 ct 600 / 5 618 ct 800 / 5 619 digital type power factor meter ( energon make ) 620 0 500 kva md controlor ( energon make ) 621 pt 100 thermo couple sensor ( 1 feet ) 2 wire 622 pt 100 thermo couple sensor ( 1 feet ) 3 wire 623 250 w infrared bulb 624 250 w infrared bulb holder 625 digital clamp on meter meco 626 digital multi meter meco 627 0 500 v meter 6 x 6 meco tools 628 box spanner set size 6 mm to 24 mm 629 cable socket crimping plier upto 400 sqmm 630 cable socket crimping plier upto 50 sqmm 631 earth testing clip 632 micro meter 0 to 25 mm 633 wire gage others 634 corbon brush hand blower / bag closing machine 635 ctc contact cleaner ( 250 ml ) 636 2 lit capacity kettle 1500 w ( bajaj ) 637 bearing retainer ( anabond ) 100 ml. 638 ucb tripring coil 110v 639 led lamp crompton / philips ( street light ) 640 12 volt 7.5 ah ups battery 641 tube light starter 642 switch & socket with box ( 5 a x 230 v ) 643 gem make 63 amps isolator 644 sm 125 ee make fuse unit hrc type 645 spacer make 3 a3 16 230 v contact block 646 neptune make kwh meter voltage coil 647 crompton make vcb tripping coil 110 v 648 18 taparia make screw driver 649 110 v pin head bulb 650 8 swg copper bare contactor 651 battery acid 652 distilled water 653 32 amps interior type simens isolator 654 led fitter emergency lamp 655 320 kva greaves make genset b check kit with lube oil 656 slazer make ammeter select switch 657 siemens make remote control with key operation 658 12 volt 24 plate 1800 mhd heavy duty genset battery exide 659 siemens timer 7 pu 60 20 660 3 / 20 copper pvc insulated cable 661 170 xl flat belt for bag closing machine 662 proximiti sensor 12 v 1 feet / 2feet length 663 kettle element 1500 watts 664 kettle connector 1500 watts 665 metal clad plug ( 230 v x 16 a ) 666 metal clad socket ( 230 v x 16 a ) 667 metal enclosure 8 x 6 668 metal enclosure 10 x 8 669 metal enclosure 6 x 6 670 metal enclosure 4 x 4 671 3 / 4 pvc hose 672 3 / 4 pvc pipe 673 3 / 4 l bend 674 3 / 4 tee 675 3 / 4 2 way junction box 676 3 / 4 3 way junction box 677 3 / 4 pvc gland set 678 tapper holder ( 2 pin ) 679 3 / 4 shaddle 680 rawal plug wood 681 3 / 4 wood screw 682 6 / 8 wood screw 683 8 / 6 wood screw 684 1 wood screw 685 1 1 / 2 wood screw 686 12mm rawal jumper 687 1 1 / 2 rawal plug pvc 688 pvc round block 689 ceiling rose 690 3 / 20 pvc coil 691 6a single pole mcb 692 3 / 16 concrete drill 693 5 amps ft switch anchor make 694 15 amps ft switch anchor make 695 3 / 4 clamp 696 flexible cable 4 sq.mm x 3 core 697 bch timer ( 440 v ) 698 bch no contactor coil ( 440 v ) 699 selectron timer ( star / delta 220 v ) 700 siemens timer 220 v ( star & delta ) 701 l & t contactor mnx 45 230 volt 702 isolator with fuse unit 63 a 703 indication lamp 230 v 704 hrc fuse 16 a ( ns ) 705 hrc fuse 10 a ( ns ) 706 hrc fuse 6 a ( ns ) 707 hrc fuse 2 a ( ns ) 708 l & t fuse 100 a x hn ( size 00 ) 709 l & t fuse 6 a x hf ( size 14 x 51 ) 710 l & t fuse 10 a x hf ( size 14 x 51 ) 711 l & t fuse 16 a x hf ( size 14 x 51 ) 712 l & t fuse 25 a x hf ( size 14 x 51 ) 713 l & t fuse 32 a x hf ( size 14 x 51 ) 714 mcb single pole 6 a 715 mcb double pole 32 a 716 flexible cable 3 core x 1 sq.mm 717 flexible hose 1 718 proximiti sensor 12 v ( 30mm dia ) 719 proximiti sensor unit 12 v 720 hrc fuse base & top 125 a 721 copper wire ( 7 / 20 ) 722 testor ( 500 v 1 / 2 length ) 723 screw driver 12 size 724 screw driver 8 size 725 cutting plier 8 size 726 carbon brush for hand grinding machine 727 carbon brush for hand drilling machine 728 bulb 12 v ( for lamp ) 729 contact cleaner ( crc ) 730 cooling fan 5 hp 731 l & t ml 1.5 contactor no volt coil 440 volts 732 hrc fuse link 32 amps & 63 ampstype tsd 733 16 amps 230 volt anchor make power plug unit 734 l&t interior switch 125 a fn 735 l&t interior switch 400 a fn 736 g.e interior switch 32 a 737 isolator 100 a 738 isolator 32 a 739 isolator 16 a 740 yule contactor ( 50 a 440 v ) 741 l&t contactor ml 2 440 v 742 l&t contactor ml 3 440 v 743 l&t contactor ml 4 440 v 744 bch pneumatic timer ( 440 v ) 745 bch d.o.l starter ( 5 hp ) 746 tc make contactor 32 a 747 tc make contactor 50 a 748 tc make mpcb 0.4 3.2 a 749 siemens olr 3tf ( 1.6 2.5 a 1hp ) 750 siemens olr 3tf ( 5 8 a ( 5hp ) 751 siemens olr 3tf ( 6.3 10a ( 7.5hp ) 752 siemens olr 3tf ( 25 36 a ( 28.40 ) 753 siemens green slider ( nc ) addoon 754 siemens blue slider ( no ) addoon 755 push button with element on ( technik ) 756 push button with element off ( technik ) 757 red indicator ( led ) 230v ( technik ) 758 yellow indicator ( led ) 230v ( technik ) 759 blue indicator ( led ) 230v ( technik ) 760 green indicator ( led ) 230v ( technik ) 761 siemens electronic timer 230 v 762 photo sensor controller 763 photo sensor 764 abb 16a cotactor 765 bch freedom series contactor 40a 766 enclosure with cover 6 x 12 x 12 767 motor terminal block 63 a 768 fiber glass sleeve 2 mm 769 fiber glass sleeve 4 mm 770 fiber glass sleeve 8 mm 771 fiber glass sleeve 10 mm 772 millinex paper 10mm 773 fibre glass wire 1.5 sq.mm 774 fibre glass wire 6 sq.mm 775 industrial exhaust fan 960 rpm 18 dia ( almonard ) ( single phase ) 776 industrial exhaust fan 960 rpm 18 dia ( almonard ) ( 3phase ) 777 cg moving & stable contact set 100a 778 cg moving & stable contact set 63 a 779 backlite fuse unit 32a 780 backlite fuse unit 16 a 781 cable gland 400 sq.mm 782 copper socket 400 sq.mm flat type 783 copper socket 85 sq.mm flat type 784 copper socket 25 sq.mm flat type 785 copper socket 35 sq.mm flat type 786 1.5 sq.mm pvc cable 787 2.5 sq.mm pvc cable 788 7 / 16 pvc wire 789 7 / 20 wire 790 toggle switch 16 a 791 flexible copper wire 15a x 3 core 792 crc 226 contact cleaner ( 250ml ) 793 mcb 4 pole 40 a 794 mcb 4 pole 32 a 795 mcb 4 pole 25 a 796 mcb 4 pole 16 a 797 kettle element 2000 watts 798 immersion heater 1500 watts 799 jaw puller 5.5 12.8 800 jaw puller 3.9 8.7 801 hylem sheet 12mm 802 fuse wire 100 a 803 load cell ( for 30 mt weigh bridge ) 804 load cell ( for 20 mt weigh bridge ) 805 load cell ( for 100kg electronic scale ) 806 load cell ( for 200kg electronic scale ) 807 load cell ( for 300kg electronic scale ) 808 load cell for 500kg electronic scale 809 motor 1 hp ( siemens ) 810 motor 2 hp ( siemens ) 811 motor 5 hp ( siemens ) 812 motor 7.5 hp ( siemens ) 813 motor 10 hp ( siemens ) 814 motor 15 hp ( siemens ) 815 motor 20 hp ( siemens ) 816 motor 25 hp ( siemens ) 817 motor 30 hp ( siemens ) 818 motor 40 hp ( siemens ) 819 motor 20 hp ( abb ) 820 motor 25 hp ( abb ) 821 motor 30 hp ( abb ) 822 motor 40 hp ( abb ) 823 motor 1 hp ( kirlosker ) 824 motor 2 hp ( kirlosker ) 825 motor 5 hp ( kirlosker ) 826 motor 7.5 hp ( kirlosker ) 827 motor 10 hp ( kirlosker ) 828 motor 15 hp ( kirlosker ) 829 motor 20 hp ( kirlosker ) 830 motor 25 hp ( kirlosker ) 831 motor 30 hp ( kirlosker ) 832 motor 40 hp ( kirlosker ) 833 starter d.o.l ( 1hp ) siemens make 834 starter d.o.l ( 2hp ) siemens make 835 starter d.o.l ( 5hp ) siemens make 836 starter ( 7.5 hp ) 440 v siemens make 837 starter ( 10 hp ) 440v siemens make 838 starter ( 20 hp ) 440v siemens make 839 starter ( 25 hp ) 440v siemens make 840 starter ( 30 hp ) 440v siemens make 841 starter ( 40 hp ) 440v siemens make 842 starter ( 7.5 hp ) 440 v l&t make 843 starter ( 10 hp ) 440v l&t make 844 starter ( 20 hp ) 440v l&t make 845 starter ( 20 hp ) 440v l&t make 846 starter ( 30 hp ) 440v l&t make 847 starter ( 40 hp ) 440v l&t make 848 remote control switch ( on / off ) lock enclose type ( siemens ) 849 empire sleeve 2.5 sq.mm 850 ml 2 spare kit ( l&t ) 851 ml 2 relay 13 24a ( l&t ) 852 ml 2 relay 24 32a ( l&t ) 853 bch olr 9.5 13.5a 854 relay connector 855 bch relay 1.07 1.7 a 856 mk i no volt coil 857 toggle switch 10 a 230 v 858 timer 800 psr selec make ( 154 500 volt ) ac ( on off off off ) 859 siemens timer ( 60 230volt ) 860 contactor 3tf 35 ( siemens ) 230 volt 35 amps 861 remote control switch ( on / off ) lock enclose type ( siemens ) 862 cv 230 volt contactor ml 2 ( l&t ) 863 star delta timer electronic series ( micon tm ) 864 l&t 125a 500 v fuse switch type fndin 865 hrc fuse carrier 63 a is;13703 type hk63h 866 fuse link l&t 400 a type hg ( bolted type ) 867 fuse link l&t 400 a type hn 2 ( bolted type ) 868 hrc fuse link l&t100 ampstype hn 000 869 exide battery 12 v xpress xp1500 150ah 870 sensor wire ( 3 wire ) 871 3 / 20 pvc copper wire ( finolex ) 872 sensor amplifier green p 812 873 bch ac3 freedom contactor ( ce 15g ) 874 temperature indicator 4 x 4 ( select make ) 875 temperature sensor 1 feet ( for dryer ) 876 temperature sensor cable ( for dryer ) capacitor 877 capacitor 1 kvar 878 capacitor 2 kvar 879 capacitor 5 kvar 880 capacitor 10 kvar 881 capacitor 15 kvar 882 capacitor 20 kvar 883 capacitor 25 kvar...

Town Panchayats - Tamil Nadu

33060428 construction of modern lpg gasifier crematorium at ward no 2 survey no 234 1, 234 3 kayalpartinam south part village burial ground in thiruchendur road, arumuganeri town panchayat, thoothukudi district. , earth work excavation for foundation in all types of soils and sub soils to full depth ( such as soils in rock / silt / light black cotton soil / ordinary soil ) except in rock requiring blasting but inclusive of shoring, shuttering and bailing out water wherever necessary and refilling the sides of foundation with excavated earth other than sand in layers of 150 mm thick well rammed and consolidated, depositing the surplus earth in places shown by the departmental officers with initial lead of 10 m and initial lift of 2 m. complete as per tnss23 & 24, v, vi ( s2 ) , vii, 9, 10 , gravek soil i depth of 2 mt , ii depth of 2 mt 3 mt , supply delivery and filling ofstone dust in layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per standard specification tnss no. 24 & 25. , plain cement concrete of mix 1 : 4 : 8 ( one part of cement four part of sand eight part of aggregates ) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. tndss no: 28 v, vi ( s2 ) v, vi ( s5a ) vii , supplying and fillingofu / s gravelfromapprovedquarry in layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per standard specification. , supplying anderrectingsteel centering including necessary supportsfor plain surfaces for reinforced cement concrete works such as coloumn footing, coloumn pedestals, plith beams, grade beams, staircase steps, etc which requires only nominal strutting using mild steel sheetsof size 90mm x60mm and 10bg stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervels etc complete in all floorscomplying with standard specification without strutting. ( tnss no or nbc no 30 ( s ) 86 86 a v, vi ( s3 ) vii , belowground level , ground floor , column , supplying ribbed tor steel rodsincluding cutting cranking fabricating assembling laying in exact position tying with soft steel wire 16 or 18 bwg etc. complete for all rcc works.as per the design given including cost ofsteel and binding wire also in all floors as per standard specification. ss86 & 86a, v, vi ( s3 ) ( s6 ) vii. , providing and laying in position standardised concrete mix m 20 grade in accordance with is 456 2000 using 20mm and down graded hard broken granite stone jelly for all rcc items of works with minimum cement contenet of 325kg / cum and maximum water cement ratio of 0.55 including admixture ( plasticiser / super plasticiser ) in recommended proportions as per is 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about ( 5.0cum ) , 7730kg of 20mm machine crushed stone jelly and with about ( 3.3 cum ) , 5156kg of 10 12mm machine crushed stone jelly and with about ( 4.79cum ) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the rcc floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requiremnents of is standards. ( no separate payment will be made by the department for the excess usage of materials ) footing, plinth beam, tie beam / lintel, ground floor roof beam, salbs, sloped roof beam and slabs30 v, vi ( s5 ) vii & 13 , below ground level , ground floor 0.00 mt to 4.50mt , plain cement concrete 1:8:16 ( one cement eight fine aggregates and sixteen coarse aggregates ) using 20mm size iss hbg metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 30 v, vi ( s5 ) vii & 13 , brick work in cm 1:5 ( one cement & five sand ) using iiclass ground moulded bricks of size 9x43 / 8x 23 / 4 standard specification including finishing, curing, etc., complete complying with standard specification 31 & similar to 31c v, vi ( s5 ) vii , below ground level , ground floor , first floor , brick partition walls of 10.80cm thickness using best quality country bricks of size 8 3 / 4 x 4 1 / 4 x 2 3 / 4 in cement mortar 1:3 ( one cement and three sand ) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. ( hoop iron reinforcement will be measured and paid for separately ) , specialplastering in cement mortor 1:3 mix ( one cement, , three sand ) 10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. complying with std. specifications.tndss no: 56, 57 , weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime ( no sand to be used ) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the rcc roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.61 v vi, ( via ) 3 , finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in cement mortar 1:3 ( one cement add three sand ) 12 mm thick mixed with water proofing compound conforming to iss at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete as per standard specification and as directed by the deparmental officers 44 h v, vi, ( s5a ) vii , 3 , paving the floor with best approved quality fine polished kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than adanga marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 ( one cement and three sand ) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., the kota stone slabs and other materials to be used shall be got approved by the executive engineer concerned before use on work, etc., complete as per standard speicification.39 a , paving the floor with pre polished concrete anti skid tiles ( required shape and design ) of 20mm thick of approved quality and colour laid in cement mortar 1:3 ( one cement and three sand ) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. ( the make and brand of the tiles should be got approved by executive engineer before use on works ) , vibrated plain cement concrete 1:2:4 ( one cement, two sand and four hard broken stone jelly ) using 20 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. ( the rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers 30 v, vi ( s5 ) vii & 13 , plastering in cement mortor 1:5 mix ( one part of cement, , five part of sand ) 12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. complying with std. specifications.tndss no: 56, 57 , supplying and painting the new plastered walls with two coats of exterior emulsion paint ( weather proof ) first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt etc. complete and including necessary plaster paris putty etc. wherever required.as per ( isi std ) ( it mustprovide excellent resistance against the growth of algae and fungi on the walls. and it must offer excellent protection against alkali and uv degradation and the durability period should be 5 years. 61 v, vi ( s4 ) 3 , providing upvc ( un plasticized polyvinyl chloride ) door: providing and fixing casement doors fabricated from un plasticized polyvinyl chloride ( upvc ) sections. profiles: the profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. the window unit should be designed with all corner joints mitred and fusion welded. windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. the sash should be of 60 x 102mm. the mullion should be of 60 x 74mm. the profiles should have co extruded seals. hardware: all the hardware like friction stays, handles should be screwed with self tapping screws. the handles, locks should be designed so that they cannot be released from outside. glazing: the window system should be glazed with 5mm plain float glass / 6mm bison lam installation: the profiles should be cut to length and welded 45 degrees. the window should be designed such that the water drainage does not pass through the reinforcement chamber. the window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. ( pwd sor page no.65 s.i no.264 ) , supplying and fixing of rolling shutters shall be pull and push type ( mannually operated ) made of 18g / 3 lathe sections which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover. these five main parts are made out of special components detailed below: curtain shall be of 18g / 3 lath sections cut to required size and filled with heavy cast iron / ms clips. for 80 ( 2.45m ) high rolling shutter lath sections provided shall be not less than 37 numbers. lock plate shall be 10g ms sheet and attached to the side brackets with 20mm square bar.side brackets shall be of 10g ms plate and cast iron u clamps shall be rivetted to the side brackets. roller shall be of heavy cast iron pullies fitted with heavy duty c class 40mm steel pipe and high tensile high carbon coil springs. 2 springs shall be supplied. side brackets shall be of 10g ms plate and cast iron u clamps shall be rivetted to the side brackets. hood cover shall be of 0.8mm crca sheet reinforced with 25mmx25mmx3mm ms angle or gate channel. the rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer etc., complete. , supplying and fixing upvc ( un plasticized polyvinyl chloride ) louvered ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mmboth profiles are reinforced with gi / 1mm 125gsm and100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. the epdm rubber ( blackcolour ) covered with all over the edges of frame and shutter.the corners and joints should be welded and cleaned.radiations pin headed glass 4mm thick should be provided inthe louvers. the window should be fixed to the wall with100% packing with screws and silicon packing all round theframes. the ventilator should be got approved from theexecutive engineer before use on work pwd sorpage no : 66 , supplying and fixing upvc ( un plasticized polyvinyl chloride ) windows of casement type ( open ) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with gi / 1mm 25gsm and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. the epdm rubber ( black colour ) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. the corners and joints should be welded and cleaned. radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. the connecting mechanism between sash and outer frame that enables opening of the window. the window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. the window should be got approved from the executive engineer before use on work page no : 65, sl no: 265 , supplying & fixingdoor shutters for solid core flush shutters with teak ply on both side with teak wood lipping alround 35mm thick, single leaf confirming to is:12406 / 1989 with 35x12mm t.w. lipping on all edges with necessary adhesives and cp screws complying with standard specifications. the rate is inclusive ofthreee coats of best quality varnish but excluding cost of furniture fittings, such as 300 mm tower bolt 2nos, 200mm towerbolt 1 no. 300mm aldrop 1 no. alu handle ornamental type 2 nos and 1no.door stopper etc complete. page no : 42 sl. no : 121 , supply and fixing of stainless steel ( salem stainless steel ) door frame ( box section using stainless steel plate of 1.6mm thick ) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel holdfast etc. pwd sor page no:: 44sl. no: 131 , manufacturing, supplying and fixing of stainless steel hand rails for staircase using 50mm dia 304l grade stainless steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. the vertical pipe has to be welded to the 100 x 100 x 6mm ms base plate encased in the base concrete. the rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete pwd sor page no:: 57sl. no: 131 , supply and fixing of m.s grills for windows, with one coat of red oxideprimer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc, complete as per standard specification. including phosphating as per isi with rust preventive primer & ready to assemble condition for easy installation at site including dismantlingmaking necessary with power drill to the accessories such as supplying and fixing holdfasts, plastic bush inserts receiver runner bottom shock absorbers etc. and steel doorcomplete as directed by the departmental officer. , painting the new iron works such as steel doors, windows, ventilators windows bars, balustrades etc, in all floor withtwo coats of best approved first quality and colour of synthetic enamel paint of approved quality, colour and brand ( to be approved by executive engineer before use on works ) over one the existing red oxide priming coat in all floors excluding cost of priming coat etc, complete complying with standard specification. ( the make, quality and colour of paint should be got approved bythe engineer in charge before use on works ) ( tnss no or nbc no 61 v vi ( 54 ) 3 ) , painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. ( the make, quality and colour of paint should be got approved by the executive engineer before use on works. ) , dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in cement mortar 1:2 ( one cement and two sand ) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. 39a , supplying, fabricating, erecting structural steel work for roofing welded or bolted type using ms channels, angles, plates and round bars etc. conforming to is specification including primer coating and enamal painting as per design given by the departmental officers etc, complete as per standard specification , fabricating supplying and fixing of pre painted galvanium iron sheets with the following specification. the materials should be of ppgi tile profile with a red colour or any other approved design 0.47mm thick 24 guage having width 1050 mm. the sheet should be g.i.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws, plastic washer.the washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of z 120 gsm paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. the sheet to be fixed with making suitable corrugated, cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. , supplying and fixing in positon indian water closet ( oriya type ) of size 580 x 440mm white glazed earthern ware of approved quality and brand with p or s trap conforming to bis with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one lime, two sand and five brick jelly ) 100mm thick and finishing the top to the required slope and including giving necessary connection to ci soil pipes ( including the cost of 100mm dia ci pipe for a length of 600mm ) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. ( the water closet should be got approved by the executive engineer before use on works ) . , supplying and fixing in position best quality and approved make indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm ( with pedestal / without pedestal ) with a pair of cast iron brackets, including cost 15mm dia brass cp pillar tap, 32mm dia b class gi waste pipe with rubber plug and chain, 15mm dia gm wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia cp brass waste coupling including fixing of wash basin using ci brackets on to the wall in position with tw plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. ( the wash hand basin and specials should be got approved by the executive engineer before use on works ) . , supplying and fixing in position white / colour glazed european water closet of best quality and approved make with 100 mm p or s trap connecting with ci pipe of 100mm dia / pvc pipe of 110mm dia, double flapped rigid pvc black seat and seat cover with cp brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity pvc / 12.5 litres capacity porcelin low level flushing tank with a pair of ci brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white pvc flush hand using indian adopter joint including all internal fittings uch as 15mm brass connections, 15mm gm wheel valve, 15mm brass nipple ( 2 nos. ) , 15mm nylon connection, tw plugs, screws and also giving necessary connection to the pvc pipe including cost of 600mm length of 110mm dia pvc pipe and painting the ci brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re doing the dismantled masonry to original condition etc. complete complying with standard specifications. ( the ewc and flushing tank wiht all accessories should be got approved by the executive enginer before use on works ) , supplyingandfixingin position best approvedof bis quality 110mm p.v.c rainwaterdownfallpipe having a pressure of 4kg / sq.cm including cost of necessary pvc shoe, pvc bend, cast iron gratings of required diameter and special clamps, brass screws, nails etc, and fixing of cast iron gratings at junction of parapet and the rcc roof slab including finishing neatly etc, complete. the rate shall be inclusive of cast of removable cast iron grating. the pvc pipe shall be fixed in wall with special type of uclamp at the centre of the pipe line in addition to those for more than 3.00mt pipe length etc, completecomplyingwithstandardspecifications. , conducting geophysical survey, quality and quantity test and transportation charges etc, ( this includes labour charges in the field, rent of the vehicle for reaching the place, rent of the instrument and excluding charges for the geologist ) , drilling150 mmdiaborewellin hard rock areas anywhere in the state inculding transportation to site of work in hardrock areas inculding labour charges for insertion of ms casing pipe and flushing of borewell and for minutes. , upto 150m below g.l. , from151m 180 m , from181m 210 m , from211m 240 m , supply and delivery of unplasticised ribbed screen pvc casing pipe of the 150mm dia in 3m length with screwed and socket end and centering guide for every 15m length of pipes as per is / 12818 / 92 and as amended from time to time to suit the borewell upto 80m depth ( c.s ) with isi marking including, loading, unloading , freight, stacking and transit insurance charges etc, complete.twad page no : 22 , supplyanddelivery of three phaseof50 lpm175 mtr head submersible pumpset of motor isi / isowith threephase panel board with two level guard and auto startas per isi specificationsincluding all cost and conveyance to site etc., complete , three phaseof50 lpm175 mtr head submersible pumpset twad page no : 98 , supply and delivery of three phase panel board star delta with two level guard and auto start suitable for submersible pumpsets and accessories including all fittings suitable for submersible pump sets.panel board should be provided as per specification. rates inclusive of packing, loading, freight, unloading, stacking, transit andinsurance charges etc, complete twad page no : 110 , supply and delivery offollowing 50 mm dia upvc column pipe and gi pipes and other special materials of good quality includingcost of materials and labour with cost for coveyence to site etccompletecomplyingwith standardspecifications. etc., , 50mm dia upvc column pipe twad page no : 24 , 50mm upvc . elbow pwd page no : 107 , 50mm upvc . union , 50mm upvcbend , 50mm gate valve twad page no : 45 , 50mm gm n.r.v twad page no : 45 , 50mm pvc mta twad page no : 27 , 50mm end pvc cap pwdpage no : 100 , 50mm dia gi flange set twad page no : 44 , 50mm m.s. clamp set twad page no : 44 , supplying and fixing of pvc insulated and sheathed 3 core 4sq.mm flat type copper cable cofirming to is 694 / 1990 and including cost and conveyance of all materials to site and labour charges etc, complete as per standard specification. twad page no ; 116 , labour charges for the erection of 50 lpm175 mtr head submersible pumpsetin borewell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tnicn switches starter, voltmeter, ammeter, three pilot lamps capacitor single phasing preventor, water level guard and laying and jionting the cables andtwin earthing as per ie rules., complete and testing the pumpset and trail run for 10 days. twad page no287 , supplying laying and jointing pvc pipes of approved quality and best varity of b class pipe of the following sizes including fixing g.i specials but excludingcost of such specials cutting threading of pipes andfixing to wall with necessary teak wood plugs, clamps and screws masking holes on the wall or drilling holesin roof and making good the dismandled portions to original conditions with necessary brick work and concrete and plastering where ever necessary with necessary scafolding charges. the pipes are to be painted with two coats of good variety and best approved quality of synthetic enamel paint over a priming coat of red oxide primer etc., complete. , 32 mm dia, pvc pipe , 20 mmdia, pvcpipe , 32mm pvc.elbow , 32mm pvc. bend , 32mm pvc. tee , 32mm pvc. end cap , 20mm pvc. bend , 20mm pvc.elbow , 20mm pvc. tee , 32mmx20mm pvc.reducertee , suppling and fixing in position15mm.diameter pvc screw down tap ( heavy duty ) of approved make conforming to i.s.specifications and quality including cost of shellac , thread etc.complying with standard specifications and including cutting and threading wherever necessary. , supplying and fixing in position first quality and approved variety of 32mm gun metal gate valve ( heavy type ) with i.s.i.mark of the following sizes including cost of shellac , thread etc, .including labour for cutting and threading of g.i.pipes etc., complete complying with standard specifications for both internal and external water supply arrangements. , supplying and fixing positionpvc nahani trap ( pvc nahani trap of size 100 x 75mm ) with stainless steel gratings with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 ( one part of lime, two part of sand and five part of 40mm gauge brick jelly ) and finished with cement mortar 1:3 ( one cement, three sand ) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the ci / pvc pipes, etc., complete complying with standard specification. ( the nahani trap should be got approved by the executive engineer before use on works ) , supplying and fixing in position best quality 110mm dia p.v.c soil / waste pipes ( 6ksc ) with specialshaving isi mark and providing leakproof joints including fixing to the wall with p.v.c / m.s clamps etc., and making connection to all sanitaryfittings, dismandling masonry / r.c.c. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications. , 110 mm dia pvc pipe , 110 mm dia pvc ellbow , 110 mm dia pvc tee , 110mm dia pvc door elbow pwd pg.no:102 , 110mm dia pvc door tee , 110mm dia pvc door yee , 90 mm dia pvc pipe , 90mm dia pvc elbow , 90mm dia pvc tee , 90mm dia pvc door elbow pwd pg.no:102 , 90mm dia pvc door tee , 90mm dia pvc door yee , supplying and fixing of 2000 liters capacity hdpe tank with is specification is 10701 / 96 the tank is meant for outdoor ( or ) indoor use complete with removable hinged top locking arrangement and to make provision to fix water supply pipe lines, necessary man hole with cover and including all pvc specials pugs, screws nails to fix the tank etc., complete and the tank should fixedfirming as directed by the departmental officers.the rate shall be inclusive of all materials, labour conveyance hoisting and fixing charges etc. ( the water tank should be got approved by the eebefore use on work. twad page no ; 85 , supplying and fixing in position c.i.manhole covers ( light or heavy duty ) of 600 x 600mm in size of best approved quality and as per standard specifications etc., complete. , supplying and fixing pvc ventilating shaft of 110mm dia ( having working pressure 4 kg. / sq.cm ) with 3 metre height including cost of pvc cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers , supplying and fixing in position indian make bewelled edge mirror of approved quality and brand of size 600 x 450mm wth necessary plastic back, pvc frame with bottom stand of approved colour with brass screws, rawal plugs etc., complete complying with standard specifications. , supplying and fixingbest approved quality brass c.p / al anodised towel rail 600mm. long and 20mm diameter with brackets of same material including cost of teak wood plugs and c.p.screws etc., complete complying with standard specifications , supplying and fixing best approved quality c.p.soap tray of size 150mm x 100mm including cost of teak woodplugs, brass screws complete complying with standardspecifications. , supply and laying of3.5 x 35 sq.mm pvc armoured ltugcable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt.layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.twad page no ; 116 , wiring with 2 x 1.5 sqmm ( 22 / 0.3 ) pvc insulated single core unsheathed copper conductor cable of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories inflush with wall with 3mm thick hylum sheet cover with tw switch box and 5a f.t. switch with continuous earth wire connection of 14 swg tc wire for making good of the concealed portion with suitable colour for pvc concealed light point / fan point ( for electronic regulator ) . etc, complete as per standard specifications. sd 24 , wiring with 2 x 1.5 sqmm ( 22 / 0.3 ) pvc insulated single core unsheathed copper conductor cable of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories inflush with wall with 150 x 100 x 113 mm tw switch box with 3mm hylum sheet cover for5a 3 pin non inter locking cs plug with continuous earth wire connection of 14 swg tc wire and making good of the concealed portion with suitable colour for concealed pvc plug point.etc, complete as per standard specificationssd 38 , wiring with 2 x 4sqmm ( 56 / 0.3 ) pvc insulated single core unsheathed copper conductor cable of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with pvc accessories inflush with wall with 150 x 100 x 113 mm tw switch box with 3mm hylum sheet cover for15a 3 pin non inter locking cs plug with continuous earth wire connection of 14 swg tc wire and making good of the concealed portion with suitable colour for concealed pvc power plug point. etc, complete as per standard specifications. sd 40 , supply and run of 2 of 1.5 sqmm ( 22 / 0.3 ) pvc insulated sc unsheathed cu.conductor of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 swg tc wire and making good of the concealed portion with suitable colour.etc, complete as per standard specifications sd 54 , earthing as per p.w.d. standard with an earth electrode of 2mtr. class b gi pipe of dia not less than 32mm complete with necessary masonry work. etc, complete as per standard specificationssd 234 , supply and fixing of 3 phase 4 wire 4 way icdb of 32 a per way with 100 a tpn mc switch with suitable trunking box ms cable entry boxes and internal connection on suitable angle iron frame work with earth connection etc, complete as per standard specificationssd. 175 , supply and fixing of horizontal type 4 way triple pole neutral mcb distribution board in sheet steel enclosure with 40 a 4 pole mcb isolater as incoming and 12 nos. 6a to 32 a sp mcb as outgoing in flush with wall and making good of the concealed portion with earth connection. the mcbdb and mcbs should be with the isi mark etc, complete as per standard specificationssd.179 , supply and run of 2 of no.8 swg gi wire for guarding with cradle with no.8 swg gi wire at the equal interval of 1.5m etc, complete as per standard specifications sd.75 , supply and run of 4 x6 sq.mm ( 84 / 0.3 ) pvc insulated sc unsheathed cu.conductor of 1100v grade on 7 / 20 gl bearer wire for service connection mains etc, complete as per standard specifications.sd 68 , supplying and laying of pvc insulated, pvc sheathed, armoured, ltug cable of size 2 core 10 sqmm al.cable clamped on walls ( sd 210 ) , supplying and fixng of cable gland and termination with earth connection of size 2 core 10 sqmm etc, complete as per standard specification. ( sd 182 ) , supply and fixing of tneb board suitable for 3 phases 63a service connection made up of suitable angle iron frame work of size 2 feet x 1 1 / 2 feet using angle iron of size 1 1 / 2 x 1 1 / 2 x 1 / 4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1 / 2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 nos 63a fuse units ( 500v ) 1 no. neutral link, copper earth flat of size 1 x 1 / 4 with inter connection of eb meter to fuse units by 7 / 16 pvc insulated copper wire with earth connection complete.sd 129 , supply and fixing of 32 a tpn mc switch on incoming and 3 nos 32 a dpmc switch ( front handle ) as outgoing with suitable adoptor box with suitable ms cable entry box trunking boxes and internal connections on internal connections on suitable ai frame work with earth connection etc, complete.sd 172 , supply and fixing of 3 phase 4 wire 4 way icdb of 16 a per way with 32 a tpn mc switch with suitable ms cable entry boxes trunking box and internal connections on suitable angle iron frame work with pwd earthing etc, complete.sd 173 , earthing as per the isi specification with an earth electrode of 2.1mt class b gi pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm rcc cover slab for the brick masonry . sd 233 , supply and run of 2 of 4sqmm ( 56 / 0.3 ) pvc insulated sc unsheathed cu.conductor of 1100v grade in suitable pvc rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14swg cuwireand making good of the concealed portion with suitable colour ( sd57 ) , supplying and laying of 3½ x 50 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 m putting 0.15 m layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. [ sd 200 ] , supplying of 4 x 10 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 m putting 0.15 m layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. [ sd 196 ] , supplying and fixing of single box type 2 x 20 w led light fitting complete with electronic choke and teakwood round blocks on wall or ceiling with fluorescent tube with pvc unsheathed copper leads from terminals to the fitting. [ twad sor electrical page no ; 173 sl. no : 15b ] , supplying and fixing of 1200mm ( 48 ) sweep ac ceiling fan complete with regulator with 1m down rod including s & f of fan clamp with side plates and cross arm etc, complete as per standard specifications sd 107 , supply and fixing of 300mm ( 12 ) sweep ac exhaust fan complete with necessary wall opening and making good of the wall.etc, complete as per standard specifications. sd 115 , brick lining for 300mm thick in furance roof fibre li 2800l x 900w x 700h in mmning chamber size, door operation : up & down movement manual operated max operating temparature : 700 900 dec celsius. etc, complete. , lpg burner set with lpg bank $ control panel: supply of 4 nos, 5 burner with blower and fully auto control system like 0, 000 kcal capacity lpg fired ignition, flame sensor and auto cut off incorperated in a separate sequencecontoller equivalent to imported contol system for air and lpg with auto igniting system and supply of 20 + 20 cylinder bank with pipeline from lpg cylinder bank up to each burner end by using tata c class grate material pipe with required material etc, complete , 3 hp motor 2no.for use to id fan & 1hp motor use for wet scrubber wet scrubber for gas cleaning system: the system should be enhanced with stainless steel cylinder and ss id fan ( 3hp motor x 2nos. with isi standard ) to avoid rusting, volume of water should be increased for effective scrubbing. , guy supported chimney: this is a cylindrical type ms is 2062 quality, 8mm plate chimney with two coasted of aluminium heat resistance paint exrernally, 7000 mm, long bottom cylindrical chimney. it is rested on 16mm type ms is 2062 qyality ( 100 feet thick base flange and stool flange 16mm thick with 12mm gusset support, cylindrical chimney mounted on foundation 12nos x 25mm dia bolt, nut joints, top 1 cylindrical shell boiler quality 8mm plate x 7000mm long base chimney. it is rested 50mm width base flange & wind forece curtain ms flat set, with lightening arrestor 25mm x 3mm copper flat earthing, with easy hinges type manual opened manhole door, necessary for pollution control boardmonitoringm sample ports arrangment ladder assembly with safety guard set 70 feet full height, one sets of detachable platform, over all size: 800mm dia x 400mm dia x 21000mm length with necessary all arrangements etc., complete , erection, testing and commissioning charges for gasifier etc, complete , supply, delivery, errection, testing and comissioning of 62.50kva generatorwith auto main failiure panel ( amp ) three phase out put voltage 415v consisting of diesel engine capable of delivery continious break gradial fitting water cooled radiclous assessory classes as per standad specificatons pwd sor page no: 146 sl.no; 10a , supply delivery and filling of brick jelly 20mm size with standard specification including cost and conveyance of jelly at site and all labour charges and all other incidential charges etc., complete as per standard specification. , supply delivery and filling of40mm size hbg stone with standard specification including cost and conveyance of jelly at site and all labour charges and all other incidential charges etc., complete as per standard specification. , supply delivery and filling of20mm size hbg stone with standard specification including cost and conveyance of jelly at site and all labour charges and all other incidential charges etc., complete as per standard specification....

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

32874835 works contract for execution of works in r / algm section in alangulam sub division works contract for execution of o&m works in r / algm section in alangulam sub division 2 loading and unloading of 9.0 mtrs. long rcc pole ( square section ) 3 excavationof9.0 mpsc poles pitrockey 4 loading and unloading of dt 5 excavation of structure pole pit 6 excavation& erection of 8 m psc pole 7 loading & unloading of8.0 mtr psc pole 8 erection of busbar arrangement with lt open tybe 9 transporting of str material 10 transporting of9.0mtr psc poles from store to site 11 transforting of line material from store to site 12 excavationof9.0 mpsc poles pit 13 erection of 9 m pole 14 erection ab switch ( complete ) 15 hg fuse set complete 16 erection of structure pole 17 jumpering 18 erection of ht las in dt structure 19 erection of top chanel cross arm 20 erection of lt las in dt structure 21 erection of lt 3q cross arm 22 fixing of 4 1 / 2v x arms 23 transforting of 63 kva dt 24 fixing of 3.5 v cross arm 25 erection of feeder cable with open type fuse unit per feeder 26 fixing of ht ti fitting 27 assemble, operating pipe fixing etc., fixing of cross bracing 28 sprading yard jally and cut stone and bricks including materials 29 erection of 63 kva & 100 kva dt 30 erection of dt seating chanel & belding chanel 31 excavation & erection of stay set complete 32 excavation & erection of stay set complete rockey 33 erection of feeder caple with lt open tybe fuse unit per feeder for additional feeder 34 paving and stringing of 7 / 3.35 acsr 35 erection of pin pont to cut point 36 paving & stringing of conductor per run 7 / 3.15 mm aaac 37 paving & stringing of conductor per run 7 / 2.59 mm acsr 38 fixing of tapping chanel cross arm 39 concreding of pole supplide by party 40 concreding of str pole 41 writing of danger board 42 painding of pole colour washing with emulation duple code str pole only 43 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 44 excavation of 3 nos. earth pits for structure 45 earthing of pole 46 excavation of earth wire trenchespaving of earth wire, erection of earthing pipegiving connect 47 masonaryworks for each earth pits for 2 nos. earth trough and concrete 48 painting pole ( colour washing with emulsion on labour only ( double coat ) 49 dismantling of lt 3q cross arm 50 dismantling of 7 / 2.59mm acsr 51 loading & unloading of9.0 mtr psc pole 52 transforting of 8 m psc pole 53 single pole tc set suitable for 25 kva dt 54 erection of square structure pole 55 erection of lt protection kit 56 erection of hg fuse, 11 kv solid core type 57 erection of11 kv 200 amps.single break gos 58 excavation of stay pit 59 erection of stay 60 paving & stringing of conductor per run 7 / 2.59mm acsr 61 ht pin point to cut point 62 concreting of structure poles 63 coping of poles 64 transformer structure pole mass concrete ( all materials including cement ( ratio 1:2:4 ) 65 mason works for earth pits and structure pole coping 66 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 67 excavation of 2 nos. earth pits for structure 68 excavation of 3 nos. earth pits for structure 69 excavation of earth wire trenchespaving of earth wire, erection of earthing pipegiving connect 70 masonaryworks for each earth pits for 2 nos. earth trough and concrete 71 dismantling of 1 ph x arm 72 dismantling of 7 / 2.59mm acsr 73 distmantling of 9.14 mtr rcc corroded pole 74 dismantling of structure materials top channel 75 dismantling of transformer seating channel and belting angle 76 dismantling of ab switch ( complete ) 77 dismantling of hg fuse set complete 78 dismantling of jumbering 79 dismantling of bus bar arrangement with open type 80 dismantling of feeder cable with open type fuse unit per feeder 81 dismantling of operating pipe fixing etc., fixing of cross bracing 82 distmantling of ht las in dt structure 83 distmantling of lt las in dt structure 84 dismantlingof transformer 85 dismantling of 3.5 v cross arm 86 dismantling of ht ti fitting 87 dismantling of of stay 88 sq static meter erectioncharges 89 sq meter dismantling charges 90 excavation of earth wire trenches, paving of earth wire, erection of earthing pipe, giving connect 91 dismantling of 7 / 2.11mm acsr 92 masinory work for each earth bit for 3nos earth through concrte...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

32874817 works contract for execution of ht works in krkn section in alangulam sub division works contract for execution of ht works in krkn section in alangulam sub division 2 loading & unloading of9 mtr psc poles 3 transporting of9mtr psc poles 4 excavation of9.0 mpsc poles pit in rocky ground 5 erectionof9mtr psc poles 6 loading & unloading ofrsj poles 7 transporting of rsj poles 8 excavation ofrsjpoles pit in rocky ground 9 erectionof rsj poles 10 erection of 3 1 / 2 v x arm 11 erection of tapping channel x arm 12 erection of ht ti fitting 13 exavation of stay bit rockey ground 14 erection ofstay set complete 15 erection of guarding arrangement 16 paving & stringing of 7 / 3.15 mm aaac conductor 17 earthing of pole 18 concreting of poles ( material supplied by contractor ) 19 excavation ofdp structure pole pits 20 erectionofdp structurepoles 21 erection of top channel x arm 22 erection of ab switch complete 23 erection of ht las 24 assemble operating pipe fixing & cross bracing set etc 25 exavation of 3 nos. earth bits 26 exavation of earth wire trenches and paving of earth wire, erection of 3 nos. earth pipe and giving earth connection and earthing of all metal parts, las etc., including central connection. 27 masonaryworks for earth pits for 3 nos. earth trough and concrete 28 spreading yard jelly and cut stone and bricks including materials 29 transporting of structure materials 30 painting of pole colour washing with emulsion double coat 31 erection of jumpering 32 concreting of structure poles 33 erection of hg fuse set complete 34 erection of 11 kv ht las 35 erection of 11 kv metering set 36 loading & unloading of 11 kv metering set...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

32874796 works contract for execution of works in seithur subdivision of rajapalayam division 3 works contract for execution of o&m works in seithur sub division 2 loading and unloading of 9 mtr long pscpoles 3 excavation ofpole pit9.0 mt 4 transporting of 9.0 mt psc pole from store to site 5 erection of 9.0 mtpoles 6 fixing of 31 / 2`v cross arm 7 fixing of ht t.i fitting 8 erection of 4.5 ft tapping channel 9 excavation of stay pit at rockey ground 10 erection of stay set complete 11 paving and strinking of conductors per run 7 / 3.15 mm aaac 12 paving and strinking of conductors per run 7 / 2.50 mm aaac 13 concreting of pole ( cement supplied by contractor ) 14 coping of pole 15 earthing of pole 16 colour washing & painting of pole 17 loading and unloading of 8 mtr long pscpoles 18 excavation ofpole pit8.0 mt 19 erection of 8.0 mtpoles 20 concreting of pole ( cement supplied by contractor ) 21 earthing of pole 22 coping of pole 23 colour washing & painting of pole 24 transporting of 8.0 mt psc pole from store to site 25 erection of lt 3 ph cross arm 26 erection of lt 3 phside arm& stud 27 fixing of lt 1 phase cross arm 28 erectionof lt line with 7 / 3.15 aaac & 3.35 acsr 29 erection of lt line with 7 / 2.50 aaac & 2.59 acsr 30 re erection of lt 3 phase cross arm 31 re erection of lt line with 7 / 2.59 acsr 32 dismantlingof lt line with 7 / 2.11 acsr 33 dismantlingof lt line with 7 / 2.50 aaac 34 dismantlingof lt line with 7 / 3.15 aaac 35 dismantling of lt 3 phase cross arm 36 dismantling of lt 1 phase cross arm 37 dismantling of 7.5 mt psc pole 38 dismantling of 7.5 mt rcc pole 39 dismantling of 7.5 mt rsj pole 40 changing of lt pin point to cut point 41 erection of transformer 42 loading & un loading of dt 63 kva 43 dismantling of 100kva 44 loading and unloading of 9 mtr long rcc pole ( square section ) 45 excavation of structure pole pit 46 erection of structure pole 47 concreating of structure pole 48 coping of pole 49 single pole tc set suitable for 25 kva dt 50 erection of lt protection kit 51 erection of hg fuse, 11 kv solid core type 52 erection of 11kv, 200 amps, single break gos 53 jumbering 54 vertically mounted 11 kv hg fuse unit with insulator 55 erection of lt las in dt structure 56 erection of feeder cable with open type fuse unit per feeder 57 fixing of 4 1 / 2v cross arms 58 fixing of tapping channel x arm 59 fixing ofht ti fitting 60 masanory work for each earth pit for 2nos earth trough and concrete 61 excavation of 2 nos. earth pits for structure 62 excavation of earth wire trenches, paving of earth wire, erection of earthing pipe, giving connect 63 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 64 spreading yard jelly and cut stone and bricks including materials 65 writing of danger board 66 assemble, operating pipe fixing etc., fixing of cross bracing 67 painting ofpole ( colour washing with emulsion on labour only ) ( double coat ) 68 painting of transformer structure ( double coat ) 69 loading and unloading of dt 70 erection of transformer 16kva&25 kva 71 excavation of stay pit at rockyground 72 erection of stayset complete 73 transporting of line materials to store 74 alteration of clamps 75 drilling og holes...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

32874782 works contract for execution of works in seithur subdivision of rajapalayam division works contract for execution of o&m works in seithur sub division 2 loading and unloading of 9 mtr long pscpoles 3 excavation ofpole pit9.0 mt 4 transporting of 9.0 mt psc pole from store to site 5 erection of 9.0 mtpoles 6 fixing of 31 / 2`v cross arm 7 fixing of ht t.i fitting 8 erection of 4.5 ft tapping channel 9 excavation of stay pit at rockey ground 10 erection of stay set complete 11 paving and strinking of conductors per run 7 / 3.15 mm aaac 12 loading and unloading of 8 mtr long pscpoles 13 excavation ofpole pit8.0 mt 14 erection of 8.0 mtpoles 15 concreting of pole ( cement supplied by contractor ) 16 earthing of pole 17 coping of pole 18 colour washing & painting of pole 19 transporting of 8.0 mt psc pole from store to site 20 erection of lt 3 ph cross arm 21 fixing of lt 1 phase cross arm 22 erectionof lt line with 7 / 3.15 aaac & 3.35 acsr 23 erection of lt line with 7 / 2.50 aaac & 2.59 acsr 24 dismantlingof lt line with 7 / 2.11 acsr 25 dismantlingof lt line with 7 / 2.50 aaac 26 dismantling of 7.5 mt psc pole 27 excavation of stay pit on rocky ground 28 erection of stay 29 loading and unloading of 9 mtr long rcc pole ( square section ) 30 excavation of structure pole pit 31 erection of structure pole 32 concreating of structure pole 33 coping of pole 34 single pole tc set suitable for 25 kva dt 35 erection of lt protection kit 36 erection of hg fuse, 11 kv solid core type 37 erection of 11kv, 200 amps, single break gos 38 jumbering 39 vertically mounted 11 kv hg fuse unit with insulator 40 erection of lt las in dt structure 41 erection of feeder cable with open type fuse unit per feeder 42 fixing of 4 1 / 2v cross arms 43 fixing of tapping channel x arm 44 fixing ofht ti fitting 45 masanory work for each earth pit for 2nos earth trough and concrete 46 excavation of 2 nos. earth pits for structure 47 excavation of earth wire trenches, paving of earth wire, erection of earthing pipe, giving connect 48 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 49 spreading yard jelly and cut stone and bricks including materials 50 writing of danger board 51 assemble, operating pipe fixing etc., fixing of cross bracing 52 painting ofpole ( colour washing with emulsion on labour only ) ( double coat ) 53 painting of transformer structure ( double coat ) 54 loading and unloading of dt 55 erection of transformer 16kva&25 kva 56 excavation of stay pit at rockyground 57 erection of stayset complete 58 transporting of line materials to store 59 alteration of clamps 60 drilling og holes 61 labour chargesfor erection of isolators with proper allingmentsincluding accessories, meggering and cost ofconsumables and lubricants and as directed by the field engineer. 62 labour chargesfor erection of 11 kv vcb breaker by usingcrane by contractor 63 labour chargesfor erection of 11 kv cts 64 labour chargesfor erection of 11 kv las 65 labour chargesfor the erection of busbar including suitable modifications of end clamps, providing holes wherever necessary as directed by the field engineer. 66 labour chargesforthe erection of jumper / droppers using a ) moose / zebra / panther conductors including modification of end clamps, providing holes etc wherever necessary as directed by the field engineer. 67 labour chargesfor 11 kv line ( 1 span ) 68 labour chargesfor dismantling of 11 kv centre rotating ab switch 69 labour chargesfor dismantling of 11 kv vcb breaker crane by contractor 70 labour chargesfor 11kv line disconnection 71 erection of plinth for breaker including jelly, bricks, cement, sand and etc. including excavating of earth pcc 1:2:4 using 20 mm hbs jelly including cost of all materials lead, lift, curing etc., complete with form work ( 2.1 x1.7 mtr ) 1 mtr depth & 60 cm height ) 72 erection of 32 r.s.j.pole 200x100mm including concrete materials like jelly, cement, sand etc. ( rs.1350+750 ) 73 36 rsjpole 74 36 rsjpole 75 36 rsjpole 76 36 rsjpole 77 concreting ofpole 78 top channel 79 seating channel and belting angle 80 11 kv centre rotating ab switch ( complete ) 81 hg fuse ( complete ) 82 jumpering 83 ht las 84 ht las 85 excavation of 3 no earth pits 86 excavation of earth wire trenches & paving of earth wire, erection of 3 no earth pipe and giving earth connection, earthing of all metal parts las etc including connection 87 assemble , operating pipe fixing etc., 88 loading & un loading of100kva dt 89 erection of 100kva dt 90 double coat of aluminium painting of good quality in all the metal parts in the dt structure including the cost of paint and accessories 91 writing of danger board 92 fixing of a / c distribution box and cable termination 93 laying of 4*120sq.mm lt alu.cable 94 erection of 11kv xlpe termination kit 95 laying of 11kv3*120sq.mm lt alu.cable 96 alteration of clamps 97 drilling of holes 98 dismantling of30 rsjpole 99 dismantling of top channel 100 dismantling ofseating channel and belting angle 101 dismantling of centre rotating ab switch with operating pipeset 102 dismantling ofhg fuse set 103 dismantling of jumpering 104 dismantling of ht las 105 dismantling of lt las 106 dismantling of distn. tr. 100 kva 107 loading & un loading of distn.tr.100 kva...

Military Engineer Services - Tamil Nadu

32767686 provision of toilet neat main gate entrance of age ( i ) r&d office at cvrde avadi 1 excavation in trenches n. exc 1.5 m in depth for foundation etc and getting out in hard / dense soil. 2 surface excavation in hard dense soil n.exc ( not exceeding ) 30cm deep and averaging 15 deep and getting out in hard / dense soil. 3 m & l for pcc type d2 1:4:8 ( 40 mm graded aggregate ) cement concrete in foundations, filling, concrete bed to drain pipes and mass concrete 4 m&l brick work with sub class ‘b’ bricks curved on plan exc 6 m mean radius built in cement mortar 1:6 5 m&l brick work with sub class ‘b’ bricks curved on plan exc 6 m mean radius built in cement mortar 1:4 6 m&l brick work with sub class ‘b’ bricks curved on plan exc 6 m mean radius built in cement mortar 1:4 in half brick thick walls 7 returning filling including spreading, levelling watering and well ramming in layers not exc 25 cm thick complete 8 removal of excavated soil exe 250m but not exe 500 m and deposited where directed. 9 m & l for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; verticle or to batter fair finish surface. 10 m & l for formwork to sides of pillars, posts, struts, piers, columns and stanchions fair finish surface 11 m & l for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc fair finish surface 12 m&l for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick ( horizontal or sloping ) 13 m & l formwork to chullah hoods, chajjas, troughs and similar items including edges fair finish 14 form work to edges of concrete slabs exc 10 cm but not exc 20 cm thick 15 m&l tmt bars 10mm dia & over cut to length bent to shape required including cranking, bending spirally for hooping for columns hookingends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed. 16 all as per srl item no 1.14 here in before but6mm to 8mm dia and stirrups complete all as specified and directed. 17 m&l for rcc m30 in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under reamed piles and mass concreteall as specified and as directed. 18 m&l forrcc m30 in columns, pillars, piers, posts and struts complete all as specified. 19 m & l for rcc m30 in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified. 20 m & l for rcc m30 in slab supported on walls, beams, and column in floors, roofs, landings, balconies, canopies, deck slabs and inshelves, chajja complete all as specified. 21 m & l for rendering 15mm thick cement mortar in two layers i.e 10mm in cm 1:6 and5mm in cm 1:4 mixed with with approved water proofingcompound as per manufacturer instruction on fair faces of brick work or concrete surfaces.note: wpc measured and paid separtely. 22 m&l rendering 10mm thick cement plaster on ceiling surfaces in cement mortar 1:4 finished fair and evenwithout using extra cement complete all as specified 23 m&l rendering 12mm thickin cement mortar ( 1:6 ) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified. 24 m&l non skid glazed ceramic coloured ( light colour as approved ) tilesof size 300x300x7 8 mm thick as in flooring set and jointed in neat cement slurry over & including 15 mm thick screed in cement mortar ( 1:6 ) as in floors / sub floors and pointed in white cement with pigment to match the colour of tiles complete all as specified. 25 m&l glazed ceramic coloured tiles in vertical surface 350x 250x 7mm / 450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 1:4 cm 10mm thick rendering rough finishedto recive tiles as in skirting / dado. 26 m&l granite galaxy 20mm thick factory polished fixedwithcement slurrypointing with coloured pigment to match the granite including cutting to shape, grinding, polishing bulnosing etc in floors with 15mm thick screed bed in cement mortar ( 1:6 ) all as specified anddirected by the engineer in charge. 27 m & l 75mm thick pccd2, 1:4:8 ( 40mm graded aggregate ) in subbase offlooring complete all as specified. 28 m &l for broken stone hardcore of gauge n exc. 63mm, broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified. 29 m&l for cement concrete ( 1:2:4 ) type b 1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as directed by engr in charge and complete all as specified. 30 m&l rendering 15 mm thick screed / cement plaster in cm 1:3 with wpc on rcc surfaces of roof / brick walls finished fair and even while the concrete is green. note : wpc shall be measured and paid seperately. 31 supply only integral water proofing compound. 32 m&l for app based polymeric membrane minimum weighing 3.5 kg / sqm and minimum 3mm thick reinfored with polyster non wooven fabric ( wt not less than 160gm / sqm ) laid over primed surfaces includingbituminous primer conforming to is 3384applied @ 0.3 ltr / sqm byby forced all as specified and directed.four course roof treatment consist of as under: ( i ) applying one coat of bituminous primer conforming to is 3384 @ 0.3 ltr / sqm. ( ii ) laying of app based membrane as specified thickness and weight. ( iii ) applying one coatbitumen grade 85 / 25@1.2kg / sqm. ( iv ) applying two coataluminium paint @100ml / sqm. 33 s&f solid pvc door frame of size 50mmx47mm made out of 5mm plain colour pvc sheetreinforced with ms square tubes s&f opening as per specification & drawings complete all as specified. 34 s&f factory made soild pvc moulded door shutter 28 to 30mm thick ( stiled ) with 2, 4, or 6 raised panel design with 2mm thick moulded pvc sheet on the front face and 2mm plain colour pvc sheet on back face with particle board core. 35 s&f 125mm long ptmt butt hinges fixed with necessary screws powder coated any colour complete all as specified and directed. 36 s&f 150mm long ptmt handles powder coated any colour oval type complete all as specified coloured 125 mm long fixed all as specified and directed. 37 s&f 150mm long ptmt barrel tower bolts powder coated any colour complete all as specified and directed. 38 s&f 250mm long aluminum sliding door bolt powder coated any colour, with hasp and staple bolt type all as specified and directed. 39 supply and fix anodised aluminium, powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. 40 s&f alumnium powder coated louvers ( movable arrangement in pair ) for ventilators including locking arrangement complete all as specified and as directed 41 s&f figured glass coloured pin headed type 4mm thick fixed to aluminium lovers in strips width not exceeding 80mm all as directed. 42 m&l for pvc ( swr ) floor trap 75 mm dia , including 40mm dia hdpe pipe up to the trap of bath room and jointing with solventwith outlet pipes, stainless steel grating etc fixed all as specified. 43 m&l pvc ( swr ) gully trap 125 / 110 mm, setting and jointing with solvent cement with outlet pipesand pcc 1:2:4 filling around trap and 25mm thick coverslab ( size as directed by eic ) complete all as specified. 44 s&f of 110 mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, fixed and laid in trenches / floors including distance pieces complete all as specified and directed. 45 s&f of 75 mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps as in swr pipes complete all as specified and directed. 46 s&f 110 mm pvc ( swr ) bend of any radius 47 s&f pvc ( swr ) junction single, ( single t ) equal or unequal for 110mm dia pipe 48 s&f 110 / 75 mm dia pvc ( swr ) reducers connected to door bend with access door complete all as specified 49 s&f 110 mm trap p or s trap pvc ( swr ) complete all as specified. 50 s&f 75 / 110 mm dia pvc ( swr ) vent cowl. 51 s&f vitreous china squatting pan, orissa pattern, size 580x440mm white / coloured with integral foot rests including flus pipe and connection to trap, and to flushing pipe, anti syphonage pipe, etc. fixed complete all as specified. 52 s&f pvc 10 ltr. capcityvalveless syphonic action type, flushing cistern, low level, white / coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc with all neccassary fittings complete all as specified directed. 53 s&f in 15 mm size pvc connections with ptmt nuts of 450 mm long complete all as specified. 54 s&f vitreous china urinal, bowl type, coloured , flush pipe and waste pipe including providing and fixing plugs, bedding urinal against wall in cm 1:2 securing urinal to plugs fixing with brackets, flush pipe, grating and union for 32mm dia pvc pipe discharge pipe connection to drain etc. 55 s&f urinal spreader of ptmt any colour for fixing with 15 mm dia pipe ( minium weight 60gms ) 56 s&f wash hand basin flat back 550x400mm vitreous chine ( white ) with cantilever brackets embedded in concrete block including the following and fixed in repairs complete all as specified ( a ) brass chromium plated waste coupling 32mm bore size ( b ) waste pipe pvc 32mm bore ( c ) angle iron / cast iron brackets ( d ) cp fancy type pillar cock 15 mm dia. 57 s&f 600x 450 mm leveled edged mirror, 5mm thick of selected quality glass mounted on hard board covered with pvc moulding as per sample kept in ge office and fixed to wooden plugs with chromium plated brass screwed all as directed. 58 m&l soap shelf, pvc white / colour appx size 450 x 125 x 40mm ( as per sample ) . make: prayag or equivalent 59 s&f in repar tubular towel rail 20mm dia d type60cm long between flanges brass chromium plated. 60 s&f bib taps, cp, fancy type screwed for 15mm bore of iron pipe or for brass ferrule and fixed all as specified. 61 s&f bathroom cabinet pvc with mirror suitable for to keep the bathroom items, size 400 x 500mm, white colour all as specified. make : priyag ( cat. no 554 ) 62 s&f stop valves, fancy type, cp with long shank and cup ( concealed typee ) , screwed both ends for 15mm bore of iron pipe or for union and fixed all as specified. 63 s&f gun metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 15mm bore pipe all as specified and directed. 64 s&f gun metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 20mm bore pipe all as specified and directed. 65 s&f in mild steel galvanized tubing 15 mm bore medium grade with fittings to walls, ceiling or laid on floor all as specified. 66 s&f in mild steel galvanized tubing 20 mm bore medium grade with fittings to walls, ceiling or laid on floor all as specified. 67 s&f ofrotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) 1000 ltr capesity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe complete all as specified and directed. 68 m&l preparing new plastered surfaces and applying two coats of white wash on soffits / ceilings etc; complete all as specified or as directed. 69 preparation of new plastered surface and apply two coat of cement base paint over a coat of primer with 2mm thick wall care putty complete all as specified. 70 preparation of newly plastered surfaces of walls and applying two coats of distemperoil emulsion over a coat of chalk whiting, on plastered surfaces with 2mm thick wall care putty complete all as specified. 71 m&l chequered cement colouredconcrete tiles 300mm x 300mm x 25mm, set, jointed and pointed in thick neat cement slurry in floors and pointed with white cements and pigments andincluding 15 mm thick screed in cement mortar ( 1:6 ) as in floors / sub floors and pointed in white cement with pigment to match the colour of tiles complete all as specified. 72 cutting existing galvanized ironwater supply pipe line up to 100 mm dia for inserting suitable size gi tee and socket of size 20mm dia for taking branch connection complete all as specified.note: excavation shall be measured and paid seperately. 73 m&l of 150mm bore salt glazed stone ware pipe grade ‘a’ as in trenches at any depth complete all as specified ( excavation , earth work & concrete shall be measured and paid separately ) . 74 m&l pcc ( 1:2:4 ) type b 0 using 12.5mm graded stone aggregate as in benching for manholes, bands , coping , bed plate etc with slightly chamfered or rounded angles including necessary form work, if any, and finishing exposed surface even and smoothwithout using extra cement 75 extra for forming fair finish to drain or channel 30cm internal girth in cement concrete using extra cement inl. forms moulds / mitred stopped ends etc. 76 m & l precast rcc 1:2:4 type b1 using 20mm graded crushed stone agg as in manhole cover slabs, of any thickness, size or shape incldg necessary form work, finished concrete surfaces fair & even in cm all as specified and directed by engr in charge. 77 cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( 1 / 2 round or 3 / 4 section ) in cement concrete 1:2:4 type b 1 smooth finished, and reforming bench ing as required ( internal dia of pipe in 150mm ) 78 m&l for point wiring with pvc insulated, frls pvc unsheathed, two single core, stranded, copper conductor cable 1.5 sqmm size, 1100v grade, drawn into and including concealed rigid non metallic pvc conduit not less then 20mm wide, isi marked with 1.5 sqmm unsheathed, stranded copper frls cable for continuous earth wire and including pressed modular metal concealed terminal boxes of reqd size and suitable size inner frame with outer cover suitable for modular switches / sockets / regulators all as specified & directed for the folowing : ( a ) one light / fan controlled by one switch 79 s&f switch piano flush type, 6 amps, 230v ac, single pole, one way. 80 s&f ceiling rose, surface type, bakelite 65x50mm three terminal 81 s&f batten 4 feet led tube light fitting 18w high lumen efficiency, min 5700k and extruded aluminium body with suitable electronic driver, 230vwith all accessories pre wired, connecting up with and including twin core twisted flexible copper cable complete inclluding taking down unserviceable ftl fitting any type any watts all as specified and directed.make: havells / wipro / philips 82 s&fbatten 2 feet led tube light fitting 10w high lumen efficiency, min 5700k and extruded aluminium body with suitable electronic driver, 230vwith all accessories pre wired, connecting up with and including twin core twisted flexible copper cable complete inclluding taking down unserviceable ftl fitting any type any watts all as specified and directed.make: havells / wipro / philips 83 sub main wiring with 2 runs of single core 2.5 sqmm 1100 volts grade, frls pvc insulated, unsheathed cable, copper conductor, multistranded drawn through and incl provision of isi markedpvc conduit 20mm dia medium grade surfcaein walls / roofs / floors etc., including provision of one run frls pvc insulated 2.5 sqmm copper conductor as earth continuity conductor and connecting to common earth dolly incl taking down u / s aluminium wiring complete all as specified and directed. note: two runs of 2.5sqmm cable, one run of earth continuity conductor shall be measured as one unit length and pvc conduit shall be measured under relevant items. 84 supply and fix ventilating fans ventil air dx white 250mm sweep, 230 / 240 volt mounting ring and louvers and shutters with clamp sets, nuts and bolts suitable for ventilatort fansincluding provn of connecting cable 1 sqmm, 3 core, pvc insulated all as specified and directed. 85 supply and fixing inof energy efficient led building security fitting of not less than 30 watt, epoxy powder coated pressure die cast aluminium housing and toughened glass with ip 66 degree of protection, system luminous efficiency morethan 100 lumens / watt and pf>0.9 with voltage range 140 to 270 volt, fitting should be provided wih inbuilt 10 kv minimum surge protection, short circuit and over voltage protection facility for driver and fitting including making electrical connection for cable connection complete all as directed. note : cable for connection of led light fitting andincluding mounting bracket of gi pipe 32 mm bore bend to shape with 2 nos ms flat 32 x 3 mm thick with suitable nuts & bolts for mounting the fitting shall be is included in this item and nothing shall be paid extra on this account 86 s&f sheet metal enclosure ( mcb db ) , single phase and neutral with suitale amps rated bus bar, double door type, 240 volts 4 way 87 s&f mcb single pole, 240 volts, 6amps, c series, 10 ka breaking capacity & connection complete all as specifed and directed. 88 s&fmcb single pole & neutral10amp, 240 volts, c series, 10 ka breaking capacity & connection complete all as specifed and directed. 89 s&f fix inearthing complete with galvanised steel earth plate electrode 60x60cm x 6.0mm thick burried directly in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to and including using of 4 mm gi wire as earthing leadby means of bolts, nuts, check nuts and washers of galvanised steel , connected to earthing test point, all as specified & indicated, including testing on completion including earth work and excavation in any type of soil / rock, pcc 1:3:6 type c1, earthing chamber, precast rcc slab 50mm thick in cement concrete 1:2:4 type b1 reinforced with welded steel wire febric weight hot less than 4 kg / sqm, funnel with gi watering pipe of 20mm bore, medium grade wire mesh and lugs, gi protection pipe of 15mm bore light grade upto 7.50 mtr long test point etc all as specified and directed....

Government Engineering College - Tamil Nadu

32737862 purchase of electrical items ( switches, cables etc ) and installation for research laboratory supply and fixing of 1 no 15a socket 1 no , 15a switch – 1 no. and5a switches – 3 nos. and5a socket 3nos with suitable metalbox and hylam sheet on wall etc , supply and fixing of 4 pole metal box with 32 amps 4 pole mcb with suitable angle iron frame on wall etc. ( the mcb should be with isi mark ) , supply and fixing of vertical type 8 way triple pole neutral mccb distribution board withip42 protection, with 160 a, 4 pole mccbas incoming 63a, tpmcb 6 and 6 nos. 32amps sp mcb as outgoing on suitableangle iron framewith earth connection only. the mccb db and mcb’s should be with isi mark. , supply and run of 2 of 1.5 sq.mm and 1.5 earth wirepvc insulated single core unsheathed copper conductor of 1100v grade in suitable pvc rigid pipe on wall and ceiling with continuous earth wire connection etc , supply and run of 2 of 4 sq.mm. ( 56 / 0.3 ) pvc insulated sc unsheathed copper conductor of 1100v grade in suitable pvc rigid pipe on wall and ceiling with continuous earth wire connection of 14 swg tc wire etc , supply and run of 4 of 6 sq.mm. ( 140 / 0.3 ) pvc insulated sc unsheathed copper conductor of 1100v grade in suitable pvc rigid pipe on wall and ceiling with continuous earth wire connection of 14 swg tc wire with etc , supply and run of 4 of 25 sq.mm pvc insulated sc unsheathed copper conductor of 1100v grade in suitable pvc rigid pipe on wall and ceiling with continuous earth wire connection of 14 swg tc wire with etc , supply and clamping of 3 ½ x 120 sq.mm pvc ltug armoured ltug cable on post or on wall with ms clamps. , supply and fixing of brass cable gland for 3 ½ x 120sq.mm pvc armoured ltug cable , supply and providing cable end termination of 31 / 2x120sq.mm pvc ltug aluminium armoured cable with necessary aluminium cable sockets by crimping etc. , supply and clarnping of 3 ½ x 95 sq.mm pvc ltug armoured ltug cable on post or on wall with ms clamps. , supply and fixing of brass cable gland for 3 ½ x 95 sq.mm pvc armoured ltug cable with earth connection , supply and providing cable end termination of 3 ½ x 95 sq.mm pvc ltug aluminium armoured cable with necessary aluminium cable sockets by crimping etc. , supply and run of 1 of no.8 swg copper wire in suitable pvc rigid pipe on wall and ceiling for earth connection , earthing as per standard with an earth electrode gi pipecomplete with necessary work etc , supply and fixing of 160a tpnmc main switchon suitable angle iron frame work withearth connection only , supply and fixing of 160a sub extension panel board of 25 / 6 copper bus bar with cable entry box with powdercoated with earth connection wall mounted type etc , supply and fixing of 200a tpnmc main switchon suitable angle iron frame work withearth connection only , supply and installation maintenance free gi earthling system comprising of 50 mm diameter and 2mtr long earth electrode of low carbon steel rod with micron bonding and 25kgs of carbonand suitable clamp etc...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

32250067 elecy cedc / north / coimbatore works contract for execution of various works under rdss schmes in seeranaicken palayam sub division of s.n.palayam division excavation of pole pits / stay set: , for pole upto 8.00m length by using jcb / manual , for pole above 8.00m length by using jcb / manual , in hard soil ( common to all size of poles ) , in rocky area ( common to all size of poles ) by blasting / manual , excavation of stay pit of 4.5 to 5 depth using jcb / manual , excavation of stay pit in hard rock soil , excavation & back filling of stay pit per location hard rock requires blasting , excavation & back filling of stay pit per location hard rock without blasting , excavation & back filling of stay pit per location medium rock and dense medium rock requires blasting , erection of poles and accessories , erection of rcc, rec, psc poles upto 8.00m length by using crane / manual , erection of rcc, rec, psc poles above 8.00m length by using crane / manual , erection of metal supports above 9m / rsj / rail pole / tubular poles , erection of stay set complete with fixing up stay wire eye, bow, guy shackle, binding etc. , erection of additional stay in the same stay rod, excluding excavation of stay pit and burial of stay rod. , erection of stay set complete in the rock area by blasting , replacement of stay rod only. ( including stay pit excavation & refilling & erection ) , replacement of guy shackle only in existing stay , fixing of line materials , v cross arm 3.5feet , v cross arm4.5 feet , v cross arm5.0 feet , fixing of lt s phase cross arm , fixing of lt 3 phase cross arm , fixing of ht / lt ti fitting , fixing of ht pin insulator with pin 11 kv , fixing of ht pin insulator with pin 22 kv , fixing of ht pin insulator with pin 33 kv , fixing of lt pin insulator , fixing of ht strain disc 11 kv , fixing of ht strain disc 22 kv , fixing of ht strain disc 33 kv , fixing of two tapping cross arm per cut point upto 33 kv line including fixing of discs, insulators and jumpering etc.. , set right of all sizes of leaning poles , fixing of shackle , fixing of aluminium knob , fixing of ht las ( 3 nos. ) , fixing of lt las ( 3 nos. ) , double channel x arm , guarding cross arm , tapping channel cross arm , fixing of open type fuse unit , providing of line spacers in lt lines 1 phase , providing of line spacers in lt lines 3 phase , fixing of lt capacitor , erection of centre rotating switch ab switch complete , set right of all sizes of leaning poles , resagging of lines for all sizes at cutpoint location per wire / span , intergrater dt metering arrangements / whole current meter , erection / dismantling metering set 11 kv / 22 kv , stringing of conductors: , paving and stringing of conductors of sizes upto 7 / 2.59 mm acsr or other equivalent conductor , paving and stringing of conductors ofabove7 / 2.59 mm acsr or other equivalent conductor upto 7 / 3.35mm acsr or other equivalent conductor , paving and stringing of conductors of one run of pvc cable line of all sizes with gi wire and reel insulator. , paving and stringing of conductors of7 / 4.09mm acsr or other equivalent conductor , paving and stringing of conductors of7 / 4.72 mm dog conductor or other equivalent conductor , releasing and reerection ( resagging ) of one run of all sizes of conductor , erection of distribution transformers: , erection of distribution transformer structure complete as per tneb standard including painting, feeders arrangrment, colour washing of rcc poles etc.. fixing of poles type to be unit ht / lt las and jumpering 3 nos earth pits with earth trough except erection of distribution transformer. ( double pole structure with 10 feet centre ) , erection of distribution transformer including loading of distribution transformer at stores and erection at structure or vice versa. , ( i ) upto 25 kva distribution transformer / metering set. , ( ii ) above 25 kva to 100 kva , ( iii ) above 100 kva to 250 kva , ( iv ) 500 kva and above , ( v ) failed dt replacement below 100 kva , ( vi ) failed dt replacement 100 kva and above , erection of 11 kv single pole structure including erection of dt complete without centre support. , erection of 11 kv single pole structure including erection of dt complete with centre support . , erection of dp structure: , erection of dp structure with stay as per tneb standard including fixing of top channel, cross bracing, concreting, painting, colour washing etc., , ( i ) with 11 kv ab switch using all types of poles of size 9.14 m and above length , ( i ) with 22 / 33 kv ab switch using all types of poles of size 9.14 m and above length , erection of single pole dp with completeand with single earth , concreting works: , concreting with 1:4:8 mix using 40 mm jelly including curing ( material + labour ) , ( i ) mass concreting of poles , ( ii ) sleeveconcreting , ( iii ) stay concreting , earthing: , ( i ) earthing of poles with gi wires 4 or 6 swg by coil earthing , ( ii ) provision of spike including earthing arrangement , ( iii ) pipe earthing including excavation of earth pit and fixing earth pipe 3 m length , ( iv ) replacing the corroded earth pipes of transformer structure and replacing the earth wire completely with aluminium lugs for termination , ( v ) replacement of corroded earth pipe , loading and unloading charges: , loading or unloading of distribution transformer , ( i ) upto 100 kva , ( ii ) above 100 kva and upto 500 kva , ( iii ) metering set of all ratios , loading or unloading of various sizes of poles , ( i ) rec, rcc, psc pole upto 8.00 m length , ( ii ) all rec, rcc pole above 8.00 m length , ( iii ) metal poles all sizes , loading of conductor , unloading of conductor , loading / unloading of iron & steel , loading / unloading of oil , loading / unloading of line materials , loading / unloading of 11 kv strain disc , loading / unloading of lt pin insulator shackle, guy shackle, lt pin, metal parts, ht pin etc., , loading / unloading of meters , ( i ) single phase meter , ( ii ) three phase meter , guarding arrangement , provision of guarding with two numbers earth pits excluding stay set erection , ( i ) flat guarding with earth pit , ( ii ) split neutral , transportation charges: , transportation of all types and sizes of poles and other associated materials from road side to pole pit and vice versa upto 0.50 km , transportation of all type of poles by bullock cart or other vehicle ( for all sizes of poles including loading and unloading ) , ( i ) for a lead upto 5 km , ( ii ) above 5 km of lead of every km , transport of metal pole of all sizes by head loads in hill areas from road side to pole pit location , ( i ) upto 1 km , ( ii ) above 1 km per each km , transporting of conductors of all sizes from road side to pit locations upto one km of conductor , ( i ) transporting of distribution transformer / line materials from stores to office / site upto 10 km distance by engaging 1 ton capacity minidor ( lorry ) , ( ii ) above 10 km , dismantling charges , dismantling of rcc, rec, psc & metal pole of all sizes including the closing of the pit , for breaking the mass concrete of all supports , dismantling of line materials , dismantling of double channel x arm , dismantling of guarding cross arm , dismantling oftapping channel x arm , dismantling of 11kv pin with insulator , dismantling of 11kv composite disc with mp , dismantling of 22kv pin with insulator , dismantling of 22kv composite disc with mp , dismantling of 33 kv pininsulator , dismantling of 33 kv disc , dismantling of 5 v x arm , dismantling of 1372 mm ( 46 ) v x arm , dismantling of 1068 mm ( 36 ) v x arm , dismantling of h.t / l.t. t.i. fitting , dismantling of3ph x arm , dismantling of1ph x arm , dismantling of aluminium knob , dismantling of lt shackle with mp , dismantling of lt pin with insulator , dismantling of lt open type , dismantling of top channel , dismantling of belting channel , dismantling of bed channel , dismantling of metering set 11 kv / 22 kv / 33 kv , dismantling of dt below 200 kva , dismantling of dt 200 kva & above but below 500 kva , dismantling of dt 500 kva , dismantling of knob , dismantling of ht las ( 3 nos ) , dismantling of lt las ( 3 nos ) , dismantling of stay set complete , ( i ) including stay rod , ( ii ) without stay rod , dismantling of conductor ofupto 7 / 3.35 including transporting the conductors to the nearest road side and stocking in coils , dismantling of conductor ofabove 7 / 3.35 including transporting the conductors to the nearest road side and stocking in coils , dismantling of transformer structure materials complete set and transporting the same from the location to the road side , dismantling of cross arm clamps ti fitting hardwares, insulators etc., , painting: , painting of distribution transformer of all capacities ( paint to be supplied by the board ) including cleaning of dt , numbering of poles including base painting and with cost of paint , painting of iron poles up to 36 ft length with double coats including cost of paint , painting of iron poles up to 40 ft 200 / 100 length with double coats including cost of paint , painting of cement poles by distember coating including cost of distember , painting of structure materials distribution transformers with aluminium paint of structure poles and writing of transformer details ( items 1 to 6 brush to be owned by the contractor ) ( paint to be supplied by department ) , service connection details painting , miscellaneous works , fixing and dismantling of single phase meter , fixing and dismantling of three phase meter , releasing and erection 1 ph sc wire [ during conductor or support change ] , releasing and erection 3 ph sc wire [ during conductor or support change ] , re examination of dt earthing ( digging , inspection and making connection in between extg. 3nos earth pipe ) , re earthing of structure completely , provision of street light, switching arrangement including fixing of meter, wiring & service board etc., , fixing of street light , destruction of pole concreting at site , retrieving grill from deteriorated rcc pole , fixing of modem including accessories , cleaning of rmu , cleaning of ring fencing , knitting of chair including supply materials. , workshop charges: , manufacturing / altering of clamps , drilling of holes in the structure materials clamps etc., , ab switch or open type side arm stud, cutting and drilling holes , manufacturing of earth pipe clamps for structure including of drilling holes and welding and clamp with earth pipe , general: , numbering of poles including cost of paint , painting of iron poles up to 36 ft length with double coats including cost of paint , painting of iron poles up to 40 ft 200 / 100 length with double coats including cost of paint , removing weed in substation yard / office premises , bush clearance out side substation yard / office premises ( light ) , jungle clearance such as kattu karuvai in the various area without uprooting , jungle clearance such as kattu karuvai in the various area with uprooting , clearing of tree braches of coconut trees , clearing of tree braches of neem, tamarind, country wood etc , leveling of ground using bul dozer , clearing of branches / trees with jcb , fencing of distribution transformer structure at road side fabrication and erection. ( including all materials ) ...

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

32010965 erection of tower and stringing of panther conductor and earth wire ( 7.52 km ) for erection of 110 kv sc line on dc tower from existing nallamanaickenpatti 110 kv ss to proposed railway traction ss at cholapuram erection of tower and stringing of panther conductor and earth wire ( 7.52 km ) for erection of 110 kv sc line on dc tower from existing nallamanaickenpatti 110 kv ss to proposed railway traction ss at cholapuram...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

31900809 work contract for various works in rural / svpr sub division work contract for various works in rural / svpr sub division , loading & unloading of 9.0 mtrs psc poles , excavation of pole pit , erectionofpoles , fixing of3 1 / 2 v x arms , fixingof ht ti fitting , fixingof tapping channel x arm , excavationof stay set inrockey ground , erection of stay set , paving and stringing of 7 / 3.35mm aaacper run , concreting of poles , earthing of poles , painting and numbering of poles , alteration of clamps , transport of 9.0 mtrs. psc from stores to site , transport of line materials from stores to site , loading & unloading of8.0 mtrs psc poles , excavation of pole pit , erectionofpoles , fixingof lt 3 phase x arms , fixingof lt single phase x arms , paving and stringing of 7 / 2.59 mm acsr conductor , excavationof stay set ( rockey ground ) , erection of stay set , lt pin point into cut point , dismantling of 8.0 mtrs psc pole , loading & unloading of9 mtrstr. poles , excavation of structure pole pits , erectionof9.0 mtrs. str.poles , concreting of structurepoles , erection oftop channel x arm , erection of dt seating channel and belting angle , erection of ab switch complete , erection of hg fuse set complete , jumpering , erection of ht las , erection of lt las , erection of bus bar arrangement with open type , erection of feeder cable with lt open type fuse unit per feeder , masonaryworks for earth pits for 3 nos. earth trough and concrete , exavation of 3 nos. earth bits for structure , exavation of earth wire trenches and paving of earth wire, erection of 3 nos. earth pipe and giving earth connection and earthing of all metal parts, las etc., including central connection. , mason works for earth pits and structure pole coping ( cement supplied by contractor ) , spreading yard jelly and cut stone and bricks including materials , writing of danger board , assemble of operating pipe fixing etc., , painting of pole colour washing with emulsion double coat ( str.pole only ) , painting of transformer structure ( double coat ) , loading & unloading of distribution transformer , erection of100 kvadt , transporting of 9.0 mtrs. psc pole stores to site , transporting of 25 kva distribution transformer , transporting of structure materials...

Tamil Nadu Transmission Corporation Limited - Tamil Nadu

31689838 earthwork excavation, stub setting concreting, supply , transport, erection of tower and stringing of zebra conductor and earth wire for rerouting the existing 230 kv pushep arasur feeder dc line on dc tower between loc 306 and 309 under dcw. earthwork excavation, stub setting concreting, supply , transport, erection of tower and stringing of zebra conductor and earth wire for rerouting the existing 230 kv pushep arasur feeder dc line on dc tower between loc 306 and 309 under dcw....

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

31468074 agri works contract in seithur sub division agri works contract in seithur sub division 2 loading and unloading of 9 mtr long pscpoles 3 excavation ofpole pit9.0 mt 4 transporting of 9.0 mt psc pole from store to site 5 erection of 9.0 mtpoles 6 fixing of 31 / 2`v cross arm 7 fixing of ht t.i fitting 8 erection of 4.5 ft tapping channel 9 erection of htside arm& stud 10 excavation of stay pit at rockey ground 11 erection of stay set complete 12 paving and strinking of conductors per run 7 / 3.15 mm aaac 13 paving and strinking of conductors per run 7 / 2.50 mm aaac 14 concreting of pole ( cement supplied by contractor ) 15 earthing of pole 16 loading and unloading of 8 mtr long pscpoles 17 excavation ofpole pit8.0 mt 18 erection of 8.0 mtpoles 19 concreting of pole ( cement supplied by contractor ) 20 earthing of pole 21 transporting of 8.0 mt psc pole from store to site 22 erection of lt 3 ph cross arm 23 erectionof lt line with 7 / 3.35 acsr 24 erection of lt line with 7 / 2.59 acsr 25 re erection of lt 3 phase cross arm 26 re erection of lt 1 phase cross arm 27 re erectionof lt line with 7 / 3.35 acsr 28 re erection of lt line with 7 / 2.59 acsr 29 dismantlingof lt line with 7 / 2.11 acsr 30 dismantlingof lt line with 7 / 2.50 aaac 31 dismantlingof lt line with 7 / 3.15aaac 32 dismantling of lt 3 phase cross arm 33 dismantling of lt 1 phase cross arm 34 dismantling of 7.5 mt psc pole 35 changing of lt pin point to cut point 36 dismantling of street light fittings 37 re erection of street light fittings 38 dismantling of street light switch box 39 re erection of street light switch box 40 erection of feeder cable with open type fuse unit per feeder 41 loading and unloading of 9 mtr long rcc pole ( square section ) 42 excavation of structure pole pit 43 erection of structure pole 44 concreating of structure pole 45 coping of pole 46 single pole tc set suitable for 25 kva dt 47 erection of lt protection kit 48 erection of hg fuse, 11 kv solid core type 49 erection of 11kv, 200 amps, single break gos 50 jumbering 51 vertically mounted 11 kv hg fuse unit with insulator 52 erection of lt las in dt structure 53 erection of feeder cable with open type fuse unit per feeder 54 fixing of 4 1 / 2v cross arms 55 fixing of tapping channel x arm 56 fixing ofht ti fitting 57 masanory work for each earth pit for 2nos earth trough and concrete 58 excavation of 2 nos. earth pits for structure 59 excavation of earth wire trenches, paving of earth wire, erection of earthing pipe, giving connect 60 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 61 spreading yard jelly and cut stone and bricks including materials 62 assemble, operating pipe fixing etc., fixing of cross bracing 63 painting ofpole ( colour washing with emulsion on labour only ) ( double coat ) 64 painting of transformer structure ( double coat ) 65 loading and unloading of dt 66 erection of transformer25 kva 67 excavation of stay pit at rocky ground 68 erection of stay set complete 69 transporting of line materials from store...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

31467988 works contract in seithur sub division works contract in seithur sub division 2 loading and unloading of 9 mtr long pscpoles 3 excavation ofpole pit9.0 mt 4 transporting of 9.0 mt psc pole from store to site 5 erection of 9.0 mtpoles 6 fixing of 31 / 2`v cross arm 7 fixing of ht t.i fitting 8 erection of 4.5 ft tapping channel 9 erection of ht side arm& stud 10 excavation of stay pit at rockey ground 11 erection of stay set complete 12 erection of flat guarding 13 paving and strinking of conductors per run 7 / 3.15 mm aaac 14 paving and strinking of conductors per run 7 / 2.50 mm aaac 15 concreting of pole ( cement supplied by contractor ) 16 earthing of pole 17 loading and unloading of 8 mtr long pscpoles 18 excavation ofpole pit8.0 mt 19 erection of 8.0 mtpoles 20 concreting of pole ( cement supplied by contractor ) 21 earthing of pole 22 transporting of 8.0 mt psc pole from store to site 23 erection of lt 3 ph cross arm 24 fixing of lt 1 phase cross arm 25 erectionof lt line with 7 / 3.15 aaac & 3.35 acsr 26 erection of lt line with 7 / 2.50 aaac & 2.59 acsr 27 re erection of lt 3 phase cross arm 28 re erectionof lt line with 7 / 3.35 acsr 29 re erection of lt line with 7 / 2.59 acsr 30 dismantlingof lt line with 7 / 2.11 acsr 31 dismantlingof lt line with 7 / 2.50 aaac 32 dismantlingof lt line with 7 / 3.15 aaac 33 dismantling of lt 3 phase cross arm 34 dismantling of lt 1 phase cross arm 35 dismantling of 7.5 mt psc pole 36 dismantling of 7.5 mt rcc pole 37 changing of lt pin point to cut point 38 loading and unloading of 9 mtr long pscpole 39 excavation of structure pole pit 40 erection of structure pole 41 concreating of structure pole ( cement contractor supply ) 42 coping of pole 43 erection of structure materials top channel 44 erection of structure seating channel & belting angle 45 erection of ab switch complete 46 erection of hg fuse set complete 47 jumbering 48 erection of ht las in dt structure 49 erection of lt las in dt structure 50 erection of feeder cable with open type fuse unit per feeder 51 erection of bus bar arrangement & open type 52 tranport of structure materialscomplete 53 fixing ofht ti fitting 54 masanory work for each earth pit for 3 nos earth trough and concrete 55 excavation of 3nos. earth pits for structure 56 excavation of earth wire trenches, paving of earth wire, erection of earthing pipe, giving connect 57 spreading yard jelly and cut stone and bricks including materials 58 assemble, operating pipe fixing etc., fixing of cross bracing 59 painting pole ( colour washing with emulsion on labour only ) ( double coat ) 60 painting of transformer structure ( double coat ) 61 erection of transformer 62 excavation of stay pit on rocky ground 63 erection of stay 64 erection of centre support for 250 kva dt 65 loading & un loading of dt 63 kva 66 transportingof dt 67 dismantling of 100kva 68 loading and unloading of 9 mtr long rcc pole ( square section ) 69 excavation of structure pole pit 70 erection of structure pole 71 concreating of structure pole 72 coping of pole 73 single pole tc set suitable for 25 kva dt 74 erection of lt protection kit 75 erection of hg fuse, 11 kv solid core type 76 erection of 11kv, 200 amps, single break gos 77 jumbering 78 vertically mounted 11 kv hg fuse unit with insulator 79 erection of lt las in dt structure 80 erection of feeder cable with open type fuse unit per feeder 81 fixing of 4 1 / 2v cross arms 82 fixing of tapping channel x arm 83 fixing ofht ti fitting 84 masanory work for each earth pit for 2nos earth trough and concrete 85 excavation of 2 nos. earth pits for structure 86 excavation of earth wire trenches, paving of earth wire, erection of earthing pipe, giving connect 87 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 88 spreading yard jelly and cut stone and bricks including materials 89 assemble, operating pipe fixing etc., fixing of cross bracing 90 painting ofpole ( colour washing with emulsion on labour only ) ( double coat ) 91 painting of transformer structure ( double coat ) 92 loading and unloading of dt 93 erection of transformer 16kva&25 kva 94 excavation of stay pit at rockyground 95 erection of stayset complete 96 transporting of line materials to store 97 alteration of clamps 98 drilling og holes...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

31467563 agri works contract for watrap sub division agri works contract for watrap sub division 2 loading & unloading of9 mtrspsc poles 3 excavation of pole pit ( 9.0 mtrs. ) 4 erectionofpoles ( 9.0 mtrs. ) 5 fixing of3 1 / 2 v x arms 6 fixingof tapping channel x arm 7 fixingof ht ti fitting 8 excavationof stay set inrockey ground 9 erection of stay set 10 paving and stringing of 7 / 3.35mm aaacper run 11 concreting of poles 12 earthing of poles 13 painting and numbering of poles 14 alteration of clamps 15 transport of 9.0 mtrs. psc from stores to site 16 transport of line materials from stores to site 17 loading & unloading of8.0 mtr psc pole 18 transporting of8.0mtr psc poles road side to bit 19 excavation & erection of8.0 mpsc poles 20 fixingof lt 3 phase x arms 21 paving and stringing of 7 / 2.59 mm acsr conductor 22 excavationof stay set ( rockey ground ) 23 erection of stay set 24 lt pin point into cut point 25 loading & unloading of9 mtrstr. poles 26 excavation of structure pole pits 2 nos. 27 erectionof9.0 mtrs. str.poles 28 concreting of structurepoles 29 erection oftop channel x arm 30 erection of dt seating channel and belting angle 31 erection of ab switch complete 32 erection of hg fuse set complete 33 jumpering 34 erection of ht las 35 erection of lt las 36 erection of bus bar arrangement with open type 37 erection of feeder cable with lt open type fuse unit per feeder 38 masonaryworks for earth pits for 3 nos. earth trough and concrete 39 exavation of 3 nos. earth bits for structure 40 exavation of earth wire trenches and paving of earth wire, erection of 3 nos. earth pipe and giving earth connection and earthing of all metal parts, las etc., including central connection. 41 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 42 spreading yard jelly and cut stone and bricks including materials 43 writing of danger board 44 assemble of operating pipe fixing etc., 45 painting of pole colour washing with emulsion double coat ( str.pole only ) 46 painting of transformer structure ( double coat ) 47 loading & unloading of distribution transformer 48 erection of25 kvadt 49 transporting of 9.0 mtrs. psc pole stores to site 50 transporting of 25 kva distribution transformer 51 transporting of structure materials...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

31467559 agri works contract for rural svpr sub division agri works contract for rural svpr sub division loading & unloading of 9.0 mtrs psc poles 3 excavation of pole pit 4 erectionofpoles 5 fixing of3 1 / 2 v x arms 6 fixingof ht ti fitting 7 fixingof tapping channel x arm 8 excavationof stay set inrockey ground 9 erection of stay set 10 paving and stringing of 7 / 3.35mm aaacper run 11 concreting of poles 12 earthing of poles 13 painting and numbering of poles 14 alteration of clamps 15 transport of 9.0 mtrs. psc from stores to site 16 transport of line materials from stores to site 17 loading & unloading of8.0 mtrs psc poles 18 excavation of pole pit 19 erectionofpoles 20 fixingof lt 3 phase x arms 21 fixingof lt single phase x arms 22 paving and stringing of 7 / 2.59 mm acsr conductor 23 excavationof stay set ( rockey ground ) 24 erection of stay set 25 lt pin point into cut point 26 dismantling of 8.0 mtrs psc pole 27 loading & unloading of9 mtrstr. poles 28 excavation of structure pole pits 29 erectionof9.0 mtrs. str.poles 30 concreting of structurepoles 31 erection oftop channel x arm 32 erection of dt seating channel and belting angle 33 erection of ab switch complete 34 erection of hg fuse set complete 35 jumpering 36 erection of ht las 37 erection of lt las 38 erection of bus bar arrangement with open type 39 erection of feeder cable with lt open type fuse unit per feeder 40 masonaryworks for earth pits for 3 nos. earth trough and concrete 41 exavation of 3 nos. earth bits for structure 42 exavation of earth wire trenches and paving of earth wire, erection of 3 nos. earth pipe and giving earth connection and earthing of all metal parts, las etc., including central connection. 43 mason works for earth pits and structure pole coping ( cement supplied by contractor ) 44 spreading yard jelly and cut stone and bricks including materials 45 writing of danger board 46 assemble of operating pipe fixing etc., 47 painting of pole colour washing with emulsion double coat ( str.pole only ) 48 painting of transformer structure ( double coat ) 49 loading & unloading of distribution transformer 50 erection of100 kvadt 51 transporting of 9.0 mtrs. psc pole stores to site 52 transporting of 25 kva distribution transformer 53 transporting of structure materials...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

31467556 works contract in nspm sub division works contract in nspm sub division 2 loading &unloading of 9.0m pole 3 transport of pole road to pit 9.0 m 4 excavation of pole pit 5 erection of pole 9.0 m 6 excavation of stay pit 7 erection of stay 8 concreting of poles 9 erection of 3 6 v xarm 10 erection oftapping xarm 11 erection ofht ti fitting 12 paving conductor, stringing, binding and jumpering etc. ( 7 / 3.35mm acsr ) 13 paving conductor, stringing, binding and jumpering etc. ( 7 / 4.09mm acsr ) 14 fixing of lt three phase cross arm 15 paving conductor, stringing, binding and jumpering etc. ( 7 / 2.59mm acsr ) 16 dismantling of 7 / 3.35mm acsr 17 dismantling of 7 / 2.59mm acsr 18 loading &unloading of rsj pole 19 transport ofrsj pole 20 excavation of rsj pole pit 21 erection ofrsj pole 22 guarding arrangement 23 dismantling of 8.00 mtr psc pole 24 dismantling of 3phase x arm 25 concreting of stays 26 top channel 27 transformer seating channel & belting angle 28 dismantling of tapping 29 erection of ab switch 30 erection of bracking set 31 jumpering 32 earthing 33 fixing of single phase x arm 34 hg fuse complete 35 ht las 36 masonary work for each earth pit for 3nos.earth trough and concreting 37 transporting of structure materials for structure involves ab switch , hg fuse etc, 38 fixing of capacitor bank in dt with wiring irrespective of capacitor 39 excavation of 3nos earth pit 40 excavation of earth wire trenches and paving of earth wire erection 3nos earth pipe and giving earth connection, earthing of all metal parts , las etc including central connection 41 painting with cement pole 42 spreading yard jally and cut stone bricks including materials 43 writing of name board and danger board 44 assemble of operating pipe fixing etc 45 erection / dismantling of transformer 46 loading& unloading of dt 47 bus bar arrangement with open type 48 erection of feeder cable with open type fuse unit per feeder and for each additional feeder 49 fixing of lighting arrester...

Tamil Nadu Generation And Distribution Corporation Limited - Tamil Nadu

31467552 works contract in rural svks sub division works contract in rural svks sub division 1 loading and unloading of poles 2 loading &unloading of 9.0m pole 3 transport of pole road to pit 9.0 m 4 excavation of pole pit 5 erection of pole 9.0 m 6 excavation of stay pit 7 erection of stay 8 concreting of poles 9 transformer seating channel & belting angle 10 ab switch complete 11 hg fuse complete 12 jumpering 13 ht las 14 lt las 15 masonary work for each earth pit for 3nos.earth trough and concreting 16 excavation of 3nos earth pit 17 excavation of earth wire trenches and paving of earth wire erection 3nos earth pipe and giving earth connection, earthing of all metal parts , las etc including central connection 18 painting with cement pole 19 spreading yard jally and cut stone bricks including materials 20 writing of name board and danger board 21 assemble of operating pipe fixing etc 22 loading& unloading of dt 23 bus bar arrangement with open type 24 erection of feeder cable with open type fuse unit per feeder and for each additional feeder 25 erection of 4 6 v xarm 26 erection of 3 6 v xarm 27 erection oftapping xarm 28 erection ofht & lt ti fitting 29 earthing 30 paving conductor, stringing, binding and jumpering etc. ( 7 / 3.35mm acsr ) 31 loading & unloading of 8.0m psc pole 32 transport of poles and 8.0 m from stores to site 33 excavation of 8.0 m psc pole 34 erection of 8.0 m pole 35 fixing of lt three phase cross arm 36 fixing of lt single phase cross arm 37 paving conductor, stringing, binding and jumpering etc. ( 7 / 2.59mm acsr ) 38 dismantling of 8.00 mtr pole 39 dismantling of 7 / 2.59mm acsr 40 alternation of clamp 41 drilling of holes 42 dismantling of lt singleph xarm 43 dismantling of stay set 44 loading &unloading of 9.0m long rcc pole square section 45 transport of pole road to pit 9.0 m ( square section ) 46 excavation of pole pit long rcc pole square section 47 erection of pole 9.0 m long rcc pole square section 48 concreting of str ( single ) poles 49 fixing of single pole tc set suitable for seating 16 kva / 25 kva dt and erection of dt 50 erection of lt protection kit 51 erection of hg.fuse, 11kv solid core type 52 erection of 11kv, 200 amps, single break gos 53 excavation of stay pit 54 erection of stay 55 erection of street light switch box 56 dismantling of lt single phase x arm...